GT – MHR Reactor Cavity Cooling System

GT – MHR Reactor Cavity Cooling System. RCCS. RCCS-SNU: water-pool type RCCS -- water natural convection -- air force convection. Seoul National University. Conduction – radiation – convection .

tarak
Download Presentation

GT – MHR Reactor Cavity Cooling System

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. GT – MHRReactor Cavity Cooling System

  2. RCCS RCCS-SNU: water-pool type RCCS -- water natural convection -- air force convection Seoul National University Conduction – radiation – convection “Heat Transport and Afterheat Removal for Gas Cooled Reactors Under Accident Conditions”, IAEA-TECDOC-1163, 2000.

  3. Conclusion from Idaho Nation Laboratory May 24 – 27, 2010 Heat removal mechanisms from RPV to cavity: – Thermal radiation (~80%) – Convection (~20%) RCCS heat removal mechanisms: Active cooling: air forced-convection Passive cooling: water boiling heat transfer & air natural convection 1. Accident fuel temperatures are insensitive to RCCS performance 2. Vessel temperatures are more sensitive to RCCS performance but still not a strong function 3. Reactor cavity concrete temperatures are a strong function of RCCS performance Y.J. Cho, M. O. Kim, G. C. Park, "Measuring Characteristics on Emissivity Using Infrared Thermometer for RCCS," NTHAS4: Fourth Japan-Korea Symposium on Nuclear Thermal Hydraulics and Safety, Sapporo, Japan, November 28-December 1, 2004

  4. Pool type RCCS Example Side tank & 12 pipes with one loop meshed 12 Bended pipe vs. straight pipes ?

  5. Experiment (a) Upper tank of the test facility (b) Side water tank

  6. Schematic diagram of the test facility

  7. Detail dimensions

  8. (80% radiation 20% conduction)

  9. 1/10 linear scaled 1/1000 volume. • 1/100 power scale. • Heat flux is preserved in the proto and model • Time scale is reduced to 1/10. • Axial distribution of temperature in water pool is not considered. • Scaling analysis is carried out to derive the similarity criteria of RPV temperature.

  10. Constant heat flux • Heat flux distribution • Cavity natural circulation(20%, 50%, 80% Helium) • Boiling heat transfer of water pool 5. Air natural convection (chimney height)