1 / 3

Hematology Analyzer ZHEA-A16

Zimed hematology analyzer offers 3-part WBC differentiation with a sampling rate of 60 samples per hour. It supports 20 parameters for blood analysis, delivering precise results with minimal sample use. Fully automatic, it provides multiple quality control methods and supports internal or external printing.<br><br>

Alissa3
Download Presentation

Hematology Analyzer ZHEA-A16

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Hematology Analyzer ZHEA-A16

  2. Hematology Analyzer ZHEA-A16 Hematology analyzer ZHEA-A16 blood counter with 3 parts differentiation of WBCs and sampling rate of 60 samples per hour. It allows setting of 20 parameters for analyzing the blood sample. They are automatic producing more precised result with less consumption of blood sample. Features: 20 parameter setting with 3 part differentiation of WBCs Sampling rate – 60 samples per hour Whole or diluted forms of blood sample Double passage counting with independent HGB measurement Operation mode : Windows operation system ( keyboard and mouse ) Stores 35,000 results including histograms Implement multiple quality control method Internal thermal sensitive or external printer Applications: Used for in-vitro diagnosis in medical fields including laboratories

  3. Specifications : Output ? 60 samples / hr Assay type 20 parameters + 3 color histograms Venous : 9.6 µL Sample volume Capillary : 9.6 µL Prediluted : 20 µL Relative humidity 10 to 90 % Electrical resistance Test principle Hemiglobincyanide method SFT method Calculation (QC) L-J, mean, X-B, SD, CV, QC WBC ? 2.5 %RBC ? 2.0%HGB ? 1.5 % Precision MCV ? 0.4 %PLT ? 5.0 % Display 10.4 inch LCD Storage 35,000 results inclusive of histograms Carryover WBC / RBC / HGB , 0.5 % , PLT 1 % Operating temperature 15 to 35 ° C Power supply 100 / 240 V (AC) 50 / 60 Hz Zimed Healthcare Inc. 1400 Broadfield Blvd, Houston, Texas 77084 USA Email: info@zimed.com | Website: Zimed | Phone: +1 302 786 1942

More Related