An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Photodetector Timing ResolutionBurle Micro-Channel Plate Photo Multiplier Tubes (MCP-PMTs) H. Wells Wulsin SLAC Group B Winter 2005

  2. Photo Multiplier Tube Specifications H.W. Wulsin

  3. End Station A Setup • Electronics: • ADC • Single threshold discriminator • TDC (25 ps/cnt) Quartz bars Pad 0 Pad 1 Path of test beam Pad 3 Pad 2 Mylar attenuators Burle MCP-PMT PiLas laser, 635 nm (int. trigger) H.W. Wulsin

  4. Limits to MCP Timing Resolution • Cross-talk between channels • Charge-sharing between pads • Electronics noise • Avalanche fluctuations [focus of this analysis] H.W. Wulsin

  5. Timing resolution varies with ADC • TDC measures hit time when pulse exceeds level set by single threshold discriminator. • Size of pulse (# photoelectrons) affects the measured hit time. • More photoelectrons reduce the variability of measured hit time (avalanche fluctuations have a smaller effect). Single photoelectron pulses (2 mV/div) ~300 photoelectrons / pulse (200 mV/div) Threshold Threshold 1 ns 1 ns H.W. Wulsin

  6. ADC Distribution of Runs 1-8, taken 11-22-04, 11-24-04 Entries ADC (counts) H.W. Wulsin

  7. TDC v. ADC, Runs 1-8 TDC TDC (counts) ADC ADC (counts) H.W. Wulsin

  8. TDC Histogram, Runs 1-8 entries TDC (counts) H.W. Wulsin

  9. Linear fit to Run 8 TDC = -0.0209(ADC) + 640.1 TDC (counts) ADC (counts) H.W. Wulsin

  10. Linear correction to Run 8 TDC TDC ADC ADC σcorr = 30.0 ps entries entries σraw = 31.0 ps H.W. Wulsin TDC TDC

  11. Linear fit to Run 7 TDC = -0.098(ADC) + 671.5 TDC (counts) ADC (counts) H.W. Wulsin

  12. Linear correction to Run 7 TDC TDC ADC ADC σcorr = 48.5 ps entries entries σraw = 53.5 ps H.W. Wulsin TDC TDC

  13. Hyperbolic fit to Runs 1-6 TDC = 632.6 + 509.8 / (ADC – 258.6) TDC (counts) ADC (counts) H.W. Wulsin

  14. Hyperbolic correction to Runs 1-6 TDC TDC ADC ADC σcorr = 320 ps σraw = 470 ps entries entries TDC TDC H.W. Wulsin

  15. Independent fits to three data sets H.W. Wulsin

  16. Optimized total fit TDC (counts) ADC (counts) By Hand: TDC = 619 + 165/√(ADC – 262) By Recursion: TDC = 619.2 + 160.7/√(ADC – 262.2) H.W. Wulsin

  17. Total correction for Runs 1-8 TDC TDC ADC ADC TDC TDC H.W. Wulsin ADC ADC

  18. Timing Resolution Correction: All Runs entries entries TDC (counts) TDC (counts) FWHM ~ 50 counts ADC FWHM ~ 15 counts ADC H.W. Wulsin

  19. Use Run 1 (maximum attenuation): ADC counts  photoelectrons entries No TDC Signal TDC Signal Recorded No TDC Signal entries entries TDC Signal Recorded entries entries ADC (counts) ADC - Pedestal (counts) ADC (counts) Pedestal value: 265.4 counts ADC Single photoelectron mean ADC: 2.1 counts 1 photoelectron = 2.1 counts ADC H.W. Wulsin

  20. Timing Resolution vs. Photoelectrons σ (ps) σ (ps) Npe Npe σ = 9.08 + 214.61 / √(Npe – 0.45) H.W. Wulsin

  21. Comparison to Previous Analysis Wells Josef (different data runs) photoelectrons photoelectrons Similar resolution spectrum H.W. Wulsin

  22. Conclusions • Achieved timing resolution of 30 – 50 ps for ~100 photoelectrons (Run 8) down to ~30 photoelectrons (Run 7). • Correction for timing – photon correlation most helpful in comparing disparate runs. • For constant number of photoelectrons, correction less useful. • Further study: • Confirm # photoelectrons per ADC count. • Examine charge-sharing between pads. H.W. Wulsin

  23. Thank you to all of Group B for your help all quarter! Thanks to all Group B for lots of help this quarter! H.W. Wulsin