BURLE update

BURLE update. Peter Križan Friday meeting, Mar 24, 2006. Burle MCP-PMT. BURLE 85011 MCP-PMT: multi-anode PMT with 2 MCPs 25 m m pores bialkali photocathode gain ~ 0.6 x 10 6 collection efficiency ~ 60% box dimensions ~ 71mm square 64(8x8) anode pads pitch ~ 6.45mm, gap ~ 0.5mm

Download Presentation

BURLE update

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. BURLE update Peter Križan Friday meeting, Mar 24, 2006

  2. Burle MCP-PMT BURLE 85011 MCP-PMT: • multi-anode PMT with 2 MCPs • 25 mm pores • bialkali photocathode • gain ~ 0.6 x 106 • collection efficiency ~ 60% • box dimensions ~ 71mm square • 64(8x8) anode pads • pitch ~ 6.45mm, gap ~ 0.5mm • active area fraction ~ 52%

  3. Burle MCP PMT beam test Resolution and number of photons (clusters) • sJ~13 mrad (per cluster) • number of clusters per track N ~ 4.5 • sJ~ 6 mrad (per track) -> ~ 4 sp/K separation at 4 GeV/c Open questions Operation in high magnetic field: • the present tube with 25mm pores only works up to 0.8T, for 1.5T need ~10mm • 10mm version with 4 channels available since June, tests done (J. Va’vra) Number of photons per ring:too small. Possible improvements: • bare tubes (52%->63%) • increase active area fraction (bare tube 63%->85%) • increase the photo-electron collection efficiency (from 60% at present up to 70%) -> Extrapolation from the present data 4.5 ->8.5 clusters per ringsJ: 6 mrad -> 4.5 mrad (per track) -> >5s p/K separation at 4 GeV/c Aging of MCP-PMTs ?

  4. 10micron pore tube The four pad 10 micron of the MCP PMT tube has finally arrived in Ljubljana (this Monday). It is still not clear to us what was the real reason for the trouble with shipping last summer...

  5. R+D report from the company Currently working on a 4-anode version of the Planacon with about 85% open-area-ratio (now 63%). It is currently only a custom product for one of the customers. They plan to finalize a general design in the next 2 months for the 4 and 64 anode versions. Working on a method to increase the QE of the photocathode from 23% (at ~400nm) to ~ 28%, hope to have the process worked out in the next few months. Plan to increase the angle of the MCP channels quite soon, which will increase the collection a little. The 10mm MCP option is not available as a standard option right now, but they expect it to be by the end of the summer. We will get the 85% open-area tube as soon as it is available.

  6. R+D report from the company - 2 Aging: they do not use the protective Al foil. Typical aging tests show a lifetime of about 10-12.5 C of extracted charge per tube (0.4-0.5 C/cm2) before the output drops by 50%. Their highest priority item right now is to increase this value. They plan to implement a proven method (?) to significantly increase the lifetime in the next quarter. They will let us know the new lifetime figure when they have the initial results. N.B. Their results looks much better than for the HPK MCp tubes without the protective Al layer 