Comparison of biliary track imaging in MR Donor Cholangiography on 1.5T and 3.0T

Comparison of biliary track imaging in MR Donor Cholangiography on 1.5T and 3.0T. Hye Sook Kim , J.H. Park, D.K. Seo, T.K. Chung, Y.M. Lee Department of Radiology, Asan Medical Center. I · N · T · R · O · D · U · C · T · I · O · N.

Download Presentation

Comparison of biliary track imaging in MR Donor Cholangiography on 1.5T and 3.0T

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Comparison of biliary track imaging in MR Donor Cholangiography on 1.5T and 3.0T Hye Sook Kim, J.H. Park, D.K. Seo, T.K. Chung, Y.M. Lee Department of Radiology, Asan Medical Center I·N·T·R·O·D·U·C·T·I·O·N MR 장비는 자장강도에 비례하여 신호대 잡음비, 대조도대 잡음비가 높아 고해상영상을 획득 할 수 있는 장점 때문에 3.0T MR장비에서 복부 자기 공명 영상 검사가 크게 증가하고 있는 추세이다. 이에 Donor MRCP검사에서 1.5T와 3.0T의 영상을 비교 분석 하여 자장 세기에 따른 Normal Donor biliary track의 영상 차에에 대해 알아보고자 하였다. M·E·T·H·O·D·S • 대상 • 20명 (남자:15명, 여자:5명, 16-57세: 평균연령30.5세 ) • 사용 장비 • Philips Intera Gyroscan 1.5T & Philips Achieva 3.0T • SENSE body coil • 검사방법 • RARE (Breath-hold single-slice rapid acquisition with • relaxation enhancement) • Respiratory-triggered 3D TSE • 평가방법 • 1. 정량적 분석 : RARE영상과 Respiratory-triggered 3D TSE MIP영상에서 CBD(Common bile duct), RHD(Right hepatic duct), LHD(Left hepatic duct)의 ROI를 설정 후 신호대 잡음비(Signal to Noise Ratio, SNR)와 대조도대 잡음비(Contrast to Noise Ratio, CNR)을 측정 • 2.정성적 분석 : 영상의학 판독의 2명, 방사선사 3명이 biliary track 해부학적 구조의 명확도와 묘출도에 대해 5단계 등 급으로 분석. 3.0T RARE 3.0T RT 3D TSE Back gruond SI LHD SI RHD SI CBD SI 1.5 T RARE 1.5T RT 3D TSE 정량적 분석 ROI 정성적 분석(Blind Test) • Parameter R·E·S·U·L·T 정성적 분석 정량적 분석 RARE(visualization scores) RT 3D TSE(visualization scores) RARE sequence 3.0T RARE 3.0T RT 3D TSE IOC Respiratiory-triggered 3D TSE sequence Variation IIIb 1.5 T RARE 1.5T RT 3D TSE A 40-year-old female donor C·O·N·C·L·U·S·I·O·N 1.5T와 3.0T에서 동일한 Sequence(RARE/Respiratory-triggered 3D TSE)를 비교, 분석한 결과 3.0T에서 정량적 분석이 높게 측정되었고, 정성적 분석은 비슷한 소견을 보였다. 3.0T를 임상에 적용 시 높은 신호대 잡음비 및 고해상도를 유지하면서 검사와 진단이 가능함으로서 Donor biliary track의 정확한 정보제공 및 영상 진단 평가와 외과적 수술 시 유용하게 쓰일 수 있으리라 사료된다. R·E·F·E·R·E·N·C·E·S 1. Mack EM, Haugan PA, Thomas J, et al.3.0T versus 1.5T MR cholangiography: a pilot study. AJR Am J Roentgenol. 2006;186:516-521. 2. Schindera ST, Miller CM, Ho LM, et al. Magnetic resonance(MR) cholangiography: quantitative and qualitative comparison of 3.0 Tesla with 1.5 Tesla. Invest Radiol 2007;42(6):399-405.

More Related