1 / 65

ПРЕЗЕНТАЦІЯ ТЕКО Травень, 2004

ПРЕЗЕНТАЦІЯ ТЕКО Травень, 2004. Reasons for Volume Flow Control (1). ПРИЧИНИ РЕГУЛЮВАННЯ ВИТРАТИ ПОВІТРЯ. Reasons for Volume Flow Control (2). Причини для застосування VAV- контролера. Параметри :. Регулювання витрати повітря згідно сучасним вимогам (Енергозбереження). Температура.

Download Presentation

ПРЕЗЕНТАЦІЯ ТЕКО Травень, 2004

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ПРЕЗЕНТАЦІЯТЕКО Травень, 2004

  2. Reasons for Volume Flow Control (1) ПРИЧИНИ РЕГУЛЮВАННЯ ВИТРАТИПОВІТРЯ

  3. Reasons for Volume Flow Control (2) Причини для застосування VAV-контролера Параметри: Регулювання витрати повітря згідно сучасним вимогам (Енергозбереження) Температура Забруднення повітря Забезпечення постійної витрати при зміні тиску Вимикання каналів Фільтри Вимикання каналів Забезпечення постійного тиску зона контролю VAV Чисті приміщення Забезпечення постійного тиску в приміщенні Медичні приміщення

  4. Versions of Volume Flow Control Варіанти контролерів витрати C onstant A ir V olume V ariable A ir V olume C A V V A V CONTROL CONTROL Постійна витрата повітря Змінна витрата повітря

  5. Function CAV (1) Функції CAV контролю

  6. Function CAV (2) Замикаюча сила Повітря кулачковий диск Плоска пружина Надувний компенсатор Стулка регулюючого клапану Регулятор витрати Функції CAV контролю

  7. Function CAV (3) Функції CAV контролю Регулятори витрат TROX (типу EN, RN та RNS) механічні. Тому вони не потребують додаткового енергопостачання. Вільно рухома регулююча стулка встановлюється аеродинамічною силою таким чином, що витрата може залишатися постійною при зміні рівня втрат тиску

  8. Function VAV (1) Функції VAV контролю

  9. Function VAV (2) + dpw Функції VAV контролю VAV контролер повітря Диференційний датчик тиску стулка - M електропривод Перетворювач Контролер витрати Кімнатний термостат

  10. Function VAV (3) Функції VAV контролю повітря - зміна витрати повітря + - - сприйняття перетворювачем M dp - реакція контролера - сигнал на електропривод - корекція положення дроселя - витрата відкоригована

  11. Функції спеціального VAV контролера для двоканальних систем

  12. Кімнатний термостат Контролер Vхол Диференційний датчик тиску Vхол Трубка перепаду тиску Vзаг dpw dpw Контролер Vзаг Перетворювач Vхол Перетворювач Vзаг Функції VAV контролю TVM – двоканальний вузол M Vхол Vзаг(постійна) M + - + - Vтепл

  13. Температура у кімнаті: 22°C dpw dpw 20°C Функції VAV контролю TVM – двоканальний вузол M Vхол Vзаг M + - + - Vтепл

  14. Номенклатура продукції CAV

  15. Номенклатура продукції CAV EN RN RNS

  16. Номенклатура продукції CAV RN RNS 8 розмірів: 80 - 400 мм 3 розміри: 80, 100, 125 мм Діапазон регулювання 1:4 діапазон регулювання 1:4 Діапазон витрати40 м3/год - 5040 м3/год Діапазон витрати40 м3/год - 504 м3/год Ручний регулюючий пристрій може бути замінено на сервопривід

  17. Номенклатура продукції CAV EN 38 розмірів (200x100 мм … 600x600 мм) Діапазон регулювання 1:4 Діапазон витрати 144 – 12.096 м3/год Ручний регулюючий пристрій може бути замінено на сервопривід

  18. Product Range CAV Acessories Номенклатура продукції CAV Acessories RN, RNS Аксесуари : Шумоглушник CA Водяний калорифер WLЕлектричний калорифер EL Шумоглушник CF Шумоглушник RS-A Шумоглушник RS-B

  19. Product Range VAV Номенклатура продукції VAV

  20. Product Range VAV Overview Номенклатура продукції VAV TVM TVZ / TVA TVJ / TVT TVRK TVLK TVR

  21. Product Range VAV TVR Номенклатура продукції VAV TVR / TVRD ( у шумозахисній оболонці ) 7 розмірів (100 мм - 400 мм) Діапазон витрати 36 м3/год - 6048 м3/год, Діапазон регулювання 1 : 10 (!) Герметичність згідно DIN 1946/4

  22. Product Range VAV TVJ/TVT Номенклатура продукції VAV TVJ, TVT / TVJD, TVTD (у шумозахисній оболонці) 45 розмірів (200 x 100 ..... 1000 x 1000 мм) Діапазон витрати 162 - 36.360 м3/год Діапазон регулювання 1 : 5 Можливість фланцевого з’єднання Жалюзі з’єднанні двобічним приводом Герметичність згідно DIN1946/4

  23. Product Range VAV TVZ/TVA TVA TVZ Номенклатура продукції VAV TVZ для припливу повітря TVA для видалення повітря 6 розмірів (125 мм – 400 м) Діапазон витрат 54 – 6048 м³/год Діапазон регулювання 1: 10 Регулююча стулка герметична Вбудований шумоглушник Аксесуари : Нагрівач Другий шумоглушник TS

  24. Product Range VAV TVM Номенклатура продукції VAV TVM – двоканальний пристрій 4 розміри (125 мм – 250 м) Діапазон витрат 162 – 2214 м³/год Обидві стулки герметичні Встановлення в будь-якому положенні Вбудований шумоглушник Оптимальне змішування потоків гарячого та холодного повітря Другий шумоглушник TS Аксесуари :

  25. Product Range VAV TVRK Номенклатура продукції VAV TVRK TVRK контролер розроблений для використання в системах кондиціювання, з агресивним середовищем. Використовується тільки мембранний перетворювач тиску.

  26. Product Range VAV TVLK Номенклатура продукції VAV TVLK TVLK був розроблений спеціально для використання в лабораторіях, для зміни витрати у витяжних шафах.

  27. Quality Control (1) Контроль якості & налаштування

  28. Quality Control (2) Контроль якості & налаштування VAV-контролерів • Заводські установки для кожного VAV-контролера: • Налаштування • Регулювання Vmin та Vmaxзгідно потреб замовника • Контроль регулювання витрати на випробувальних установках • Міжнародна документація заводських налаштувань

  29. Selection Criterias (1) Вибір

  30. Вибір Для правильного регулювання повинні бути розглянуті усі задачі які покладаються на регулятор, а також необхідні параметри його роботи

  31. Selection Criterias (3) Вибір Розташування: Приплив Системи: Звичайна Видалення Двоканальна Акустичні характеристики: Дуже високі Габарити: низька висота для встановлення Високі Низькі мала довжина Якість повітря: нормальна Небезпечна(агресивна, отруйна, ..) стандартна Комплектація: лабораторна витяжка, витяжка з шаф Constant Air Volume Variable Air Volume Режим регулювання: Контроль за: Витрата повітря Тиск у приміщенні Тиск у каналі

  32. Selection Criterias Location Вибір Розташування: Приплив System: Single duct Видалення Dual duct Acoustic criteria: Very high Geometry: Low Installation Height CAV EN, RN, RNS VAV TVA, TVR,TVJ/TVT,TVRK, TVLK CAV EN, RN, RNS VAV TVM, TVZ, TVR,TVJ/TVT High Low Short Length Air Quality: Normal Dangerous (Aggressive, Poisonous, ..) Standard Application: Laboratory Extract, Fume Copboard Constant Air Volume Variable Air Volume Control Mode: Control of: Air Volume Room Pressure Duct Pressure

  33. Selection Criterias System Вибір Location: Supply Air Системи: Звичайна Extract Air Двоканальна Acoustic criteria: Very high Geometry: Low Installation Height CAV EN, RN, RNS VAV TVA, TVZ, TVR,TVJ/TVT,TVRK, TVLK CAV -- VAV TVM High Low Short Length Air Quality: Normal Dangerous (Aggressive, Poisonous, ..) Standard Application: Laboratory Extract, Fume Copboard Constant Air Volume Variable Air Volume Control Mode: Control of: Air Volume Room Pressure Duct Pressure

  34. Selection Criterias Acoustics Вибір Location: Supply Air System: Single duct Extract Air Dual duct Акустичні характеристики: Дуже високі Geometry: Low Installation Height Високі CAV EN, RN, RNS VAV TVRTVJ/TVT CAV EN + Silencer, RN + Silencer VAV TVZ, TVATVJ/TVT + TXTVR + SilencerTVM CAV END + Silencer, RND + Silencer VAV TVZD + TS, TVAD + TSTVJD/TVTD+TXTVRD + Silencer TVMD + TS Низькі Short Length Air Quality: Normal Dangerous (Aggressive, Poisonous, ..) Standard Application: Laboratory Extract, Fume Copboard Constant Air Volume Variable Air Volume Control Mode: Control of: Air Volume Room Pressure Duct Pressure

  35. Selection Criterias Geometry Вибір Location: Supply Air System: Single duct Extract Air Dual duct Acoustic criteria: Very high Габарити: низька висота для встановлення High CAV RN, RNS VAV TVR CAV EN VAV TVJ/TVT Low мала довжина Air Quality: Normal Dangerous (Aggressive, Poisonous, ..) Standard Application: Laboratory Extract, Fume Copboard Constant Air Volume Variable Air Volume Control Mode: Control of: Air Volume Room Pressure Duct Pressure

  36. Selection Criterias Air Quality Вибір Location: Supply Air System: Single duct CAV EN, RN, RNS VAV TVA, TVZ, TVR,TVJ/TVT,TVM CAV -- VAV TVRK,TVLK Extract Air Dual duct Acoustic criteria: Very high Geometry: Low Installation Height High Low Short Length Якість повітря: нормальна Небезпечна(агресивна, отруйна, ..) Standard Application: Laboratory Extract, Fume Copboard Constant Air Volume Variable Air Volume Control Mode: Control of: Air Volume Room Pressure Duct Pressure

  37. Selection Criterias Application Вибір Location: Supply Air System: Single duct CAV EN, RN, RNS VAV TVA, TVZ, TVR,TVJ/TVT,TVM CAV -- VAV TVRK CAV -- VAV TVLK Extract Air Dual duct Acoustic criteria: Very high Geometry: Low Installation Height High Low Short Length Air Quality: Normal Dangerous (Aggressive, Poisonous, ..) стандартна Комплектація: лабораторна витяжка, витяжка з шаф Constant Air Volume Variable Air Volume Control Mode: Control of: Air Volume Room Pressure Duct Pressure

  38. Selection Criterias CAV Вибір Location: Supply Air System: Single duct Extract Air Dual duct Acoustic criteria: Very high Geometry: Low Installation Height High Low Short Length Air Quality: Normal Dangerous (Aggressive, Poisonous, ..) Standard Application: Laboratory Extract, Fume Copboard Constant Air Volume Variable Air Volume Режим регулювання: Контроль за: Room Pressure Duct Pressure Витрата повітря

  39. Selection Criterias CAV Example Постійна витрата повітря ВИДАЛЕННЯ ТИП RNEN ТИП RNEN ПРИПЛИВ

  40. Selection Criterias VAV Вибір Location: Supply Air System: Single duct Extract Air Dual duct Acoustic criteria: Very high Geometry: Low Installation Height High Low Short Length Air Quality: Normal Dangerous (Aggressive, Poisonous, ..) Standard Application: Laboratory Extract, Fume Copboard Constant Air Volume Variable Air Volume Режим регулювання: Контроль за: Room Pressure Duct Pressure Витрата повітря

  41. Selection Criterias VAV Example Master Slave (1) Змінна витрата повітря Залежний контрольний сигнал≙ дійсна витрата припливного повітря контрольний сигнал VПР≥ VВИД Другорядний Головний ВИДАЛЕННЯ ТИП TVRTVJ / TVTTVZTVS ТИП TVRTVJ / TVTTVA ПРИПЛИВ Тип контролера Belimo: BC0, B13Siemens: LN0Sauter (електр.)Sauter (пневмо.) Тип контролера Belimo: BC0, B13Siemens: LN0Sauter (електр.)Sauter (пневмо.)

  42. Selection Criterias VAV Example Master Slave (2) Змінна витрата повітря Контрольний сигнал залежний контрольний сигнал≙ дійсна витрата видаляємого повітря VПР≤ VВИД Другорядний Головний ВИДАЛЕННЯ ТИП TVRTVJ / TVTTVZTVS ТИП TVRTVJ / TVTTVA ПРИПЛИВ Тип контролера Belimo: BC0, B13Siemens: LN0Sauter (електр.)Sauter (пневмо.) Тип контролера Belimo: BC0, B13Siemens: LN0Sauter (електр.)Sauter (пневмо.)

  43. Selection Criterias Room Pressure Вибір Location: Supply Air System: Single duct Extract Air Dual duct Acoustic criteria: Very high Geometry: Low Installation Height High Low Short Length Air Quality: Normal Dangerous (Aggressive, Poisonous, ..) Standard Application: Laboratory Extract, Fume Copboard Constant Air Volume Variable Air Volume Режим регулювання: Контроль за: Air Volume Duct Pressure Тиск у приміщенні

  44. Selection Criterias Function Room Pressure Робота кімнатного контролеру тиску VAV контролер Кімната 1 Припливне повітря Видаляєме повітря кімната 2(еталонна) регулююча стулка M електропривід dpRoom перетворювач контролер

  45. Selection Criterias Example Room Pressure „Simple“ (1) Робота кімнатного контролеру тиску Еталонний тиск видалення приплив dp Кімнатний тиск ТИП RNEN ТИП TVRTVJ / TVT НЕБЕЗПЕКА! Тип контролерів Belimo: BG3 РІШЕННЯ „ПРОСТЕ“

  46. Selection Criterias Example Room Pressure „Simple“ (2) Робота кімнатного контролеру тиску Еталонний тиск dp Кімнатний тиск dP = потрібна величина РІШЕННЯ „ПРОСТЕ“

  47. Selection Criterias Example Room Pressure „Simple“ (3) Робота кімнатного контролеру тиску Еталонний тиск V to Vmin/max dp Кімнатний тиск dP = 0 Pa Час роботи приводуmin  max~150 сек РІШЕННЯ „ПРОСТЕ“

  48. Selection Criterias Example Room Pressure „Simple“ (4) Робота кімнатного контролеру тиску Еталонний тиск V =довільне значення dp Кімнатний тиск dP >> потрібна величина Час роботи приводуmin  max~150 сек РІШЕННЯ „ПРОСТЕ“

  49. Selection Criterias Example Room Pressure „Simple“ (5) Робота кімнатного контролеру тиску Еталонний тиск V =довільне значення dp Кімнатний тиск dP >> потрібна величина Конструктивні пошкодження РІШЕННЯ „ПРОСТЕ“

  50. Selection Criterias Example Room Pressure „Advanced“ еталонний тиск . 15% V . . 100% V 85% V Кімнатний тиск Робота кімнатного контролеру тиску Залежний контрольний сигнал≙ дійсна витрата припливного повітря контрольний сигнал dp Другорядний Основний ВИДАЛЕННЯ ТИП TVRTVJ / TVTTVZTVS ТИП TVRTVJ / TVT ПРИПЛИВ Тип контролерів Belimo: BC0, B13 Тип контролерів V: Belimo: BC0, B13 dp: Belimo: BG3 РІШЕННЯ „ПОЛІПШЕНЕ“