1 / 26

CLIC: CALIFES et nouvelles activités RF en bande X

CLIC: CALIFES et nouvelles activités RF en bande X. Généralités sur CLIC CALIFES (CEA+LAL+CERN) Démarrage et commissioning Déphaseur de puissance Banc de test 12 GHz au CERN Modulateur haute tension, klystron Composants RF de puissance 12 GHz

zorion
Download Presentation

CLIC: CALIFES et nouvelles activités RF en bande X

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CLIC: CALIFES et nouvellesactivités RF en bande X • Généralités sur CLIC • CALIFES (CEA+LAL+CERN) • Démarrage et commissioning • Déphaseur de puissance • Banc de test 12 GHz au CERN • Modulateur haute tension, klystron • Composants RF de puissance 12 GHz • Structure accélératrice 12 GHz avec wakefield monitors • Planning ROSCOFF 12 Octobre 2009 F. Peauger

  2. Concepts clefs du collisionneur lineaire e+e- CLIC • Haute fréquence 12 GHz et haut gradient 100 MV/m → collisionneur compact • Un seul tunnel, sans élément actif à l’intérieur • Schéma classique Klystron-modulateur remplacé par un faisceau fort courant appelé Drive Beam • Puissance transportée dans le Drive Beam au lieu des guides d’ondes habituels • Recombinaison des paquets du Drive Beam • → permet d’augmenter le courant et de générer des pulses RF courts sans compresseur d’impulsion RF • Nouveau type de structures décelératrices appelées PETS pour extraire et transférer la puissance aux structures accélératrices Energie nominale = 3 TeV dans le centre de masse Luminosité = 6 . 1034 cm-2 s-1

  3. Schéma général de CLIC Version 3 TeV = 48.3 km Version 500 GeV = 13 km

  4. Module CLIC à deux faisceaux PETS-6.5 MV/m, 136 MW, 213 mm Drive Beam 100A Main Beam 1A Structures acceleratrices+100 MV/m, 64 MW, 229 mm Longueur du module = 2 m, quantité = 10462 à 3 TeV

  5. CTF3 et participation CEA CHARGES RF 12 GHz pour TBL DELAY LOOP 4 A – 1.2 ms 150 Mev COMBINERRING 32 A – 140 ns 150 Mev Two Beam Test Stand DRIVE BEAM LINAC FAISCEAU SONDE CALIFES 0.9 A – 21 ns – 170 MeV 10 m CLEX CLIC Experimental Area STRUCTURE ACCELERATRICE WAKEFIELD MONITOR 12 GHZ BANC DE TEST 12 GHz

  6. Implantation de CALIFES dans CTF3 Profileur de faisceau Longueur totale = 25 mètres environ LAL Orsay CEA/DEN BPM

  7. Résultats de CALIFES (Wilfrid Farabolini) Canon • Photo-canon (LAL): • Taille transverse du faisceau: s = 2.9 à 3.2 mm • Energie en sortie de canon : E = 5.7 MeV • Charge par paquet: Q = 0.25 nC/paquets (spéc: 0.6) • Fin de ligne: • Taille transverse du faisceau: s = 1.1 à 1.6 mm • Energie maximale atteinte: E = 143 MeV (spéc: 180 MeV). • - Améliorer la compression d’impulsion RF • - le beamloading se voit nettement. • Emittance normalisée : e = 43.6 mm.mrad(horiz.) • e = 68.6 mm.mrad(vert.) • (spéc. < 20 mm.mrad). • - Devrait s’améliorer en augmentant l’énergie et le spot laser • Longueur de paquet : sz = 1.42 ps(specif. 0.75 ps) • - Le pulse laser dure 6 ps • - la compression d’impulsion dans la 1ere structure LIL fonctionne • - On attend l’installation du déphaseur de puissance Dipôle

  8. Déphaseur de puissance CEA Permet le réglage précis de la phase de la section de compression et donc de la longueur des paquets • Déphasage par variation de la longueur d’onde guidée et utilisation du mode TE01O 350 kg 1 m DeuxConvertisseurs de mode Cylindre coulissant Cylindre 1 Cylindre 2 • Brasage réussi au CERN • Reprise mécanique • Essai de nettoyage sans immersion en cours par • N. Rouviere et JP Prestel • Test de translation et soudure soufflet à venir • 4 Brasages étagés à BODYCOTE (reste 1) • Transmission / pertes = -0.23 dB -> 95% de conversion • Reflexion < -30 dB sur 12 MHz de bandepassante

  9. Banc de test 12 GHz au CERN Permet de tester les structures accélératrices indépendamment de CTF3 et à une fréquence de répétition plus élevée (50 à 100 Hz au lieu de 5 Hz) afin d’obtenir une statistique de taux de claquages plus rapidement Contribution CEA Saclay

  10. Modulateur haute tension Développement d’un modulateurétatsolide par SCANDINOVA (1.8 x 3 x 2 m3) Specification : Tension = 450 kV Courant = 335 A Largeur du plat d’impulsion = 1.5 µs Largeur à mi-hauteur= 2.3 µs Fréquence de répétition = 50 Hz Ondulation haute tension= ± 0.25 % Stabilité pulse à pulse= ± 0.1 % L1 COMMUTATEUR ETAT SOLIDE TRANSFORMATEUR D’IMPULSION KLYSTRON ALIMENTATION CONTINUE L2 L3 1000VDC 1000V 450kV

  11. Klystron XL5 SLAC Développement d’un nouveau klystron 12 GHz par le SLAC, basésur le model existant à 11.4 GHz Specification : Fréquence = 11.9942 GHz Puissance de sortie = 50 MW Rendement d’intéraction = 40 % Gain = 50 dB Pervéance = 1.2 µA/V1.5 Tension cathode = 405 kV Courant cathode = 308 A Puissance focalisateur = 30 kW 4 cavités couplées en sortie 2 convertisseurs de mode 1 fenêtre fonctionnant sur le mode circulaire TE01 4 pompes ioniques dont une à la haute tension

  12. Utilisation du mode circulaire TE01 Pour guides d’onde circulaires de rayon a (m) Pour guides d’onde rect. de dimensions a x b (m²) With Rs the surface resistance, p’01=3.832 the first root of J’0 which is the derivative of the Bessel function of first kind J0, b the propagation constant, k the wavenumber, kc the cut-off wavenumber and h = 376.7 ohm the impedance of free-space. (“Microwave Engineering”, D.M. Pozar, p.125 and 136):

  13. Vanne RF et convertisseur de mode CEA Conception et fabrication en collaboration CEA/CERN de composants RF de puissance spécifique Specifications : Fréquence = 11.994 GHz Puissance = 100 MW Largeur d’impulsion = 300 ns Fréquence de répétition = 50 Hz

  14. Implantation du banc de test 12 GHz

  15. Charge RF de puissance pour la ligne TBL Transmission vers le pick-up = -49.1 dB Specifications : Fréquence = 11.994 GHz Puissance = 80 MW Largeur d’impulsion = 300 ns Fréquence de répétition = 5 Hz Mag E – log scale @ 11.9942 GHz for 1W in ¼ structure Développementd’une charge compact instrumenté CEA basésur un design CERN Reflection = -44.8 dB • Utilisation de l’inox magnétique 430 • Perméabilité relative µr = 800 • Conductivité électrique = 1.66e6 S/m • Usinage dans la masse de demi-corps et soudure par faisceau d’électron

  16. Wakefield Monitor pour Structure Accélératrice 12 GHz Le Wakefield monitor (WFM) est un détecteur de position du faisceau intégré à la structure accélératrice utilisé en fonctionnement pour l’alignement des structures à 5 µm par rapport au faisceau Permet de réduitfortement le grossissementd’emittancey et d’atteindre la luminositénominale Participation du CEA - Phase 1: Design et fabrication d’un WFM prototype, intégration dans une structure 12 GHz CERN et test avec faisceau CALIFES • Calculs GDFIDL sur cluster LXCLIC du CERN • 360e6 mailles – 13 heures de calcul par run Y+ Amplitude des signaux recombinés pour un offset faisceau de 1 mm (Volts) U1 U0 X- DX=X+-X- X+ DY=Y+-Y- Y- Donné par HFSS Temps (s) Donné par Gdfidl

  17. Linéarité et spectre en fréquence du WFM Amplitude max. du signal recombiné (volt) Offset dx (mm) Recombined port signal amplitude 14.7 GHz 16.76 GHz F (Hz) 17

  18. Wakefield Monitors pour Structures Accélératrices 12 GHz Participation du CEA - Phase 2:Fabrication de 2 ou 3 structures equipées d’un WFM et test sur le TBTS avec RF provenant des PETS et avec faisceau CALIFES L’objectif est aussi de tendre vers le gradient nominal de 100 MV/m avec faisceau • Usinage diamant à ±1.2 µm et rugosité Ra = 0.025 • Montage en salle blanche • Assemblage par diffusion sous H2 à 1030°C • Dégazage sous vide à 650°C pendant 72h Disque Quantité: 24 par structures WFM Quantité: 4 par structures Qualification de deuxsociétésd’usinage en cours

  19. Planning de CLIC et des activités CEA Projet CLIC Approuvé ? Premier Faisceau ? CDR TDR

  20. Extra-slides

  21. Caractéristiques et spécifications de CALIFES • 1 photo-injecteur • 3 sections LIL : 1 pour la compression longitudinale des paquets et deux pour l’accélération • 1 systeme RF composé d’un klystron et d’un compresseur d’impulsion RF de type BOC • 1 ligne diagnostique faisceau

  22. Composants RF de puissance 12 GHz BANC DE TEST 12 GHz Specifications : Fréquence = 11.994 GHz Puissance = 80 à 100 MW Largeur d’impulsion = 300 ns Fréquence de répétition = 50 Hz Convertisseur de mode ~130 x 130 mm Quantité: 6 Vanne RF Quantité: 2 Design RF : CEA Design mécanique: CERN Fabrication : CEA / CERN Nouvelle charge de puissance instrumentée inox 430 Longueur : 65 cm Quantité: 16 Guides coudés 90° plan E Quantité: 16 LIGNE TBL

  23. Compresseur d’impulsion RF SLED1 GYCOM

  24. TIC meeting 23 sept. 09 - Wilfrid Farabolini Améliorations laser • Globalement le laser a une très bonne disponibilité et est stable en énergie, position, timing (merci a Nathalie, Marta et Massimo). • Possibles améliorations: • Dérive journalière de la puissance (due a la température dans la salle laser) : charge passe de 3.7 nC le matin a 2.8 nC le soir • Energie sur la photocathode (conversion et transport) pour atteindre 0.5nC/bunch • Durée minimal des pulses (specif. single bunch : 0.67 ns) • Forme de la tache sur la photocathode

  25. Amplitude max. du signal (voltage) offset

More Related