Chapter 5 transform analysis of linear time-invariant system

Chapter 5 transform analysis of linear time-invariant system. 5.1 the frequency response of LTI system 5.2 system function 5.3 frequency response for rational system function 5.4 relationship between magnitude and phase 5.5 all-pass system 5.6 minimum-phase system

tameron
Download Presentation

Chapter 5 transform analysis of linear time-invariant system

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Chapter 5 transform analysis of linear time-invariant system 5.1 the frequency response of LTI system 5.2 system function 5.3 frequency response for rational system function 5.4 relationship between magnitude and phase 5.5 all-pass system 5.6 minimum-phase system 5.7 linear system with generalized linear phase

  2. magnitude response or gain magnitude square function log magnitude magnitude attenuation 5.1 the frequency response of LTI system magnitude-frequency characteristic:

  3. transform curve from linear to log magnitude log magnitude linear magnitude

  4. phase response principal phase continuous phase group delay phase-frequency characteristic:

  5. Figure 5.7

  6. understand group delay EXAMPLE Figure 5.1

  7. Figure 5.2

  8. EXAMPLE Difference about zeros and poles in FIR and IIR 5.2 system function Characteristics of zeros and poles: (1)take origin and zeros and poles at infinite into consideration, the numbers of zeros and poles are the same. (2)for real coefficient, complex zeros and poles are conjugated, respectively. (3)if causal and stable, poles are all in the unit circle. (4)FIR:have no nonzero poles, called all-zeros type, steady IIR:have nonzero pole; if no nonzero zeros , called all-poles type

  9. 5.3 frequency response for rational system function 1.formular method

  10. 2. Geometrical method

  11. EXAMPLE magnitude response in w near zeros is minimum, there are zeros in unit circle, then the magnitude is 0; magnitude response in w near poles is maximum;zeros and poles counteracted each other and in origin does not influence the magnitude.

  12. EXAMPLE

  13. EXAMPLE

  14. 3.matlab method EXAMPLE B=1 A=[1,-0.5] figure(1) zplane(B,A) figure(2) freqz(B,A) figure(3) grpdelay(B,A,10)

  15. 5.4 relationship between magnitude and phase

  16. Figure 5.20 EXAMPLE Pole-zero plot for ,H(z): causal and stable, Confirm the poles and zeros

  17. 5.5 all-pass system Zeros and poles are conjugate reciprocal For real coefficient, zeros are conjugated , poles are conjugated.

  18. EXAMPLE Y N Y Y

  19. application: 1. compensate the phase distortion 2. compensate the magnitude distortion together with minimum-phase system Characteristics of causal and stable all-pass system:

  20. 5.6 minimum-phase system inverse system:

  21. explanation: (1)not all the systems have inverse system。 (2)inverse system may be nonuniform。 (3)the inverse system of causal and stable system may not be causal and stable。 the condition of both original and its inverse system causal and stable: zeros and poles are all in the unit circle,such system is called minimum-phase system, corresponding h[n] is minimum-phase sequence。 poles are all in the unit circle, zeros are all outside the unit circle, such system is called maximum-phase system。

  22. minimum-phase system: conjugate reciprocal zeros and poles all-pass system: counteracted zeros and poles, zeros and poles outside the circle minimum-phase and all-pass decomposition: If H(z) is rational, then : poles outside the unit circle zeros outside the unit circle

  23. Application of minimum-phase and all-pass decomposition: Compensate for amplitude distortion Figure 5.25

  24. (1)minimum phase-delay (2)minimum group-delay Minimum-phase system and some all-pass system in cascade can make up of another system having the same magnitude response, so there are infinite systems having the same magnitude response. Properties of minimum-phase systems:

  25. (3)minimum energy-delay(i.e. the partial energy is most concentrated around n=0)

  26. EXAMPLE 最小相位 minimum phase maximum phase Systems having the same magnitude response Figure 5.30

  27. minimum phase Figure 5.31

  28. Figure 5.32

  29. 5.7 linear system with generalized linear phase 5.7.1 definition 5.7.2 conditions of generalized linear phase system 5.7.3 causal generalized linear phase (FIR)system

  30. Strict: Generalized: phase 5.7.1 definition Systems having constant group delay

  31. EXAMPLE ideal delay system EXAMPLE differentiator:magnitude and phase are all linear physical meaning: all components of input signal are delayed by the same amount in strict linear phase system ,then there is only magnitude distortion, no phase distortion. it is very important for image signal and high-fidelity audio signal to have no phase distortion. when B=0, for generalized linear phase, the phase in the whole band is not linear, but is linear in the pass band, because the phase +PI only occurs when magnitude is 0, and the magnitude in the pass band is not 0.

  32. EXAMPLE square wave with fundamental frequency 100 Hz linear phase filter: lowpass filter with cut-off frequency 400Hz nonlinear phase filter: lowpass filter with cut-off frequency 400Hz

  33. Generalized linear phase in the pass band is strict linear phase

  34. Generalized linear phase in the pass band is strict linear phase

  35. 5.7.2 conditions of generalized linear phase system Or:

  36. M:even M:odd Figure 5.35 M:not integer

  37. EXAMPLE M:not integer

  38. EXAMPLE determine whether these system is linear phase,generalized or strict?a and ß=? (1) (2) (3) (4)

  39. 5.7.3 causal generalized linear phase (FIR)system

  40. Magnitude and phase characteristics of the 4 types:

  41. I II

  42. III IV

  43. Characteristic of zeros: commonness

  44. Figure 5.41 Characteristic of every type:

  45. type I: type II: type III: type IV: characteristic of magnitude get from characteristic of zeros:

  46. M is even M is odd low high band pass band stop low high band pass band stop h[n] is even (I) Y Y Y Y Y N Y N (II) h[n] is odd (III) N N Y N N Y Y N (IV) Application of 4 types of linear phase system:

  47. 5.1 the frequency response of LTI system : 5.2 system function 5.3 frequency response for rational system function: 5.4 relationship between magnitude and phase : 5.5 all-pass system 5.6 minimum-phase system 5.7 linear system with generalized linear phase (FIR) 5.7.1 definition: 5.7.2 conditions : h[n] is symmetrical 5.7.3 causal generalized linear phase system 1.condition 2.classification 3.characteristics of magnitude and phase , filters in point respectively 4.analyse of characteristic of magnitude from the zeros of system function summary

  48. requirement: concept of magnitude and phase response, group delay; transformation among system function, phase response and difference equation; concept of all-pass, minimum-phase and linear phase system and characteristic of zeros and poles; minimum-phase and all-pass decomposition; conditions of linear phase system , restriction of using as filters key and difficulty: linear phase system

  49. exercises 5.17 complementarity:minimum-phase and all-pass decomposition 5.21 5.45 5.53