Varian Integration System. TrueBeam 2.0 New Features. TrueBeam 2.0 Standard Package. Usability enhancements Automation for more fields (gated fields, bolus) Field reordering on treatment application Goto next field inside bunker ( Muti Iso Center)

Varian Integration System - slide 1
01 / 14Varian Integration System
1 / 17

Download Presentation

Varian Integration System
An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

More Related Content

Presentation Transcript
  1. Varian IntegrationSystem TrueBeam 2.0 New Features

  2. TrueBeam 2.0Standard Package Usability enhancements Automation for more fields (gated fields, bolus) Field reordering on treatment application Gotonext field inside bunker (MutiIso Center) Performance improvements for large plans with IGMA multi-core architecture Improvements in the match GUI (16:9 monitors) Imaging improvements

  3. TrueBeam 2.0Standard Package QA mode improvements • Match and Shift • Adhocimaging • Automation • Gotofor couch axes • Edit/Acquire/Override • Background color change for QA mode

  4. TrueBeam 2.0Standard Package • Advanced IGRT & Motion Package • Motion Management Interface • Dynamic Tracking (MLC tracking, Couch tracking) (Developer Mode) • Varian 6DoF Couch • 2.5X Imaging Beam (2.5MV)

  5. TrueBeam 2.0Standard Package Advanced IGRT & Motion Package • 2D/3D match • On-demand imaging • On-line match approval (on-line review) • Triggered Image acquisition (mu,time,angle) • Structures on pre-Txfluoro and kV radiographs • Advanced Reconstructor (4D CBCT, multi-scan CBCT)

  6. TrueBeam 2.0Standard Package • Pause the treatment and verify patient setup • kV radiograph • kV/MV image pair • Reference image will be calculated automatically at any gantry angle • Calculate and apply shift • Continue treatment

  7. Advanced IGRT & Motion PackageTrigered Image acquisition

  8. Advanced IGRT & Motion PackageTrigered Image acquisition • Image acquisition during treatment delivery • Respiration • Time • Gantry angle • Monitor units • Reference image is calculated automaticaly • Eclipse structures can be displayed

  9. Advanced IGRT & Motion PackageTrigered Image acquisition

  10. Advanced IGRT & Motion PackageAdvanced Reconstructor - 4D CBCT

  11. Motion Management - Tracking TrueBeam 2.0

  12. TrueBeam™ 2.0Dynamic MLC/Couch Tracking

  13. TrueBeam™ 2.0Dynamic MLC/Couch Tracking

  14. TrueBeam™ 2.xSmall Treatment Room Solution Minimal distance from isocenteruntillwall: 2.87 meter • TrueBeam ‚Long‘: 3.50 meter • Silhouette: 2.92 meter • TrueBeam ‚Slim‘: 2.87 meter • UNIQUE: 2.40 meter