1 / 6

Smart Meter Texas AMS data Validation criteria and daily sync file

Smart Meter Texas AMS data Validation criteria and daily sync file. September 19, 2014. Definitions. LSE Load Star Enhanced file format used for movement of AMS usage data for both TDSPs to ERCOT and TDSPs to SMT. LSE AMS ESIID Usage Data Header Record:

saram
Download Presentation

Smart Meter Texas AMS data Validation criteria and daily sync file

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Smart Meter TexasAMS data Validation criteriaand daily sync file September 19, 2014

  2. Definitions • LSE • Load Star Enhanced file format used for movement of AMS usage data for both TDSPs to ERCOT and TDSPs to SMT. • LSE AMS ESIID Usage Data Header Record: • Each ESIID has 5 header records of master information including ESIID, Channel, REP DUNS, TDSP DUNS, etc. • LSE AMS ESIID Usage Data Detail Record(s): • Each ESIID has 24 detail records. Each detail record contains 4 AMS usage 15 minute intervals. Thus equaling 96 interval reads. The detail record also contains status indicating estimate or actual. • LSE AMS ESIID Usage Data Set: • One ESIID including its 5 header records with channel, start time and end time and 24 detail records • The SMT Validation Rules are Applied to the SMT Database and not to the SMT FTPS

  3. SMT AMS Data Validation Rules • First validate all header records exist and unduplicated • Fails – Reject entire ESIID LSE AMS usage data set and send error message to TDSP • Passes – Move to next validation • Second validate detail records exist and unduplicated • Fails – Reject entire ESIID LSE AMS usage data set and send error message to TDSP • Passes – Move to next validation • Third validate each header record contains all of the required fields • Fails – Reject entire ESIID LSE AMS usage data set and send error message to TDSP • Passes – Move to next validation • Fourth validate header fields are syntax correct • Fails – Reject entire ESIID LSE AMS usage data set and send error message to TDSP • Passes – Move to next validation

  4. SMT AMS Data Validation Rules • Fifth validate ESIID (valid ESIID that exists in the SMT database populated from TDSP sync files) • Fails – Reject entire ESIID LSE AMS usage data set and send error message to TDSP • Passes – Move to next validation • Sixth validate TDSP is owner of ESIID • Fails – Move to next validation and send error message to TDSP • Passes – Move to next validation • Seventh validate REP DUNS (REP DUNS matches SMT database ROR (either current or past) populated from TDSP sync files) • Fails – Reject entire ESIID LSE AMS usage data set and send error message to TDSP • Passes – Move to next validation • Eighth validate meter is energized and meter is active • Fails – Reject entire ESIID LSE AMS usage data set and send error message to TDSP • Passes – Move to next validation • Ninth validate interval data (field values match expected LSE format) • Fails – Reject entire ESIID LSE AMS usage data set and send error message to TDSP • Passes – Move to next validation

  5. Sync Files • I-Sync File • Incremental sync file. • Received daily from all TDSPs. • Contains only the population of ESIIDs that have changes. • F-Sync File • Full sync file. • Received weekly from Oncor on Sundays. • Contains the entire population of ESIIDs for Oncor. • Sync File Contents • Master Premise – Contains new ESIIDs or updates to existing ESIIDs customer information. • ROR Update – Contains the changing relationship between ESIIDs and ROR • Master Meter – Contains new meter information. • Monthly Billed – Contains monthly billed usage • Use of Sync Files • Update master information for ESIIDS, RORs and Meters on SMT.

  6. QUESTIONS

More Related