180 likes | 255 Views
RSSI TRF7960EVM DIRECTIONS. STEP 1: SET PROTOCOL AND CHECK REGISTER SETTINGS. SCOPE SCREEN SHOT IN SPI MODE SET PROTOCOL (ISO15693, HIGH DATA RATE, TX_ON). STEP 2: SET RX WITH DIRECT COMMAND 1517. SCOPE SCREEN SHOT IN SPI MODE SET RECEIVER 1517 (GUI) or 97h (actual command).
E N D
SCOPE SCREEN SHOT IN SPI MODE SET PROTOCOL(ISO15693, HIGH DATA RATE, TX_ON)
SCOPE SCREEN SHOT IN SPI MODE SET RECEIVER 1517 (GUI) or 97h (actual command) THIS IS DUMMY CLK 1 0 0 1 0 1 1 1
STEP 3: CHECK INTERNAL RF WITH DIRECT COMMAND 1518 OR EXTERNAL RF WITH DIRECT COMMAND 1519 DIRECT COMMAND 1518 (CHECK INTERNAL RF) SHOWN
SCOPE SCREEN SHOT IN SPI MODE CHECK INTERNAL RF 1518 (GUI) or 98h (actual command) THIS IS DUMMY CLK
STEP 4: READ REGISTER WITH DIRECT COMMAND 12ØF (FROM ISSUING DIRECT COMMAND 1518 PRIOR TO DIRECT COMMAND 120F SHOWN) Internal RSSI Value (in this case)
SCOPE SCREEN SHOT IN SPI MODE READ RSSI VALUE 120F (GUI) or 4Fh (actual command)RSSI VALUE (FROM CHECK EXTERNAL RF = 5Ch) THIS IS DUMMY CLK THIS IS 5Ch
ALT STEP 4: READ REGISTER WITH DIRECT COMMAND 12ØF (FROM ISSUING DIRECT COMMAND 1519 PRIOR TO DIRECT COMMAND 120F SHOWN) External RSSI Value (in this case)
SCOPE SCREEN SHOT IN SPI MODE READ RSSI VALUE 120F (GUI) or 4Fh (actual command)RSSI VALUE (FROM CHECK INTERNAL RF = 78h) THIS IS DUMMY CLK THIS IS 78h
STEP 5: CHANGE CHIP STATUS CONTROL REGISTER TO ’01’ (TURNS OFF TRANSMITTER)
STEP 7: CHECK INTERNAL RF WITH DIRECT COMMAND 1518 OR EXTERNAL RF WITH DIRECT COMMAND 1519 DIRECT COMMAND 1518 (CHECK INTERNAL RF) SHOWN
STEP 8: READ REGISTER WITH DIRECT COMMAND 12ØF (FROM ISSUING DIRECT COMMAND 1518 PRIOR TO DIRECT COMMAND 120F SHOWN) Internal RSSI Value (in this case)
ALT STEP 8: READ REGISTER WITH DIRECT COMMAND 12ØF (FROM ISSUING DIRECT COMMAND 1519 PRIOR TO DIRECT COMMAND 120F SHOWN) External RSSI Value (in this case)
SCOPE SCREEN SHOT IN SPI MODE READ RSSI VALUE 120F (GUI) or 4Fh (actual command)RSSI VALUE (FROM CHECK INTERNAL RF = 40h) THIS IS DUMMY CLK THIS IS 40h