An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ASME B&PV Code for In-Service Inspection of Nuclear Containment Buildings Steven G. Brown, PE

  2. Introduction • Why is this of interest outside the nuclear industry? • Professional Development Hour • More than that – sharing information across various industries for improvement of the profession • Acknowledgements • K. R. Rao – Campion Guide to ASME Boiler and Pressure Vessel Code • Working Group Containment • Entergy • Disclaimer – The views presented are my own • If it’s right, it’s because my mentors got it right, • If it’s messed up, it’s probably my original idea.

  3. Terminal Objective • At the conclusion of the class the engineer will have a basic understanding of the current rules requiring inservice inspection of nuclear containment vessels.

  4. Enabling Objectives • State the purpose of containment vessel as used at commercial nuclear power plants in the US • Describe the general types of containment vessels currently used in the US commercial nuclear power industry. • State the difference between Class MC and Class CC components. • State the regulations requiring inservice inspection of nuclear containment buildings.

  5. Enabling Objectives (cont) • Be able to state the section of ASME Code providing requirements for inservice inspection of Class CC components of nuclear containment vessels. • Discuss the type and frequency of inservice examinations for nuclear power plant containment vessels.

  6. Purpose of Containment • 10 CFR 50 - GDC 16 Containment Designs - Key design requirement for all U.S. commercial nuclear plants. • Establish an essentially leak tight barrier against the uncontrolled release of radioactivity into the environment • Ensure that the containment design conditions important to safety are cont exceeded for as long as required for post-accident conditions.

  7. Typical Steel Containment Vessels • Steel Pressure Vessel – Class MC • Typically Carbon Steel • Approx. 40 to 60 psi • > 100 Feet Diameter • > 200 Feet Tall • Shell thickness 1.5” or more • Concrete Shield Building Containment Design Diagrams on this and subsequent slides are from EPRI TM-102C

  8. Typical Steel Containment Vessels • BWR Mark I – Class MC (typical) • Nominal 62 psi • Removable Head • Torus suppression pool

  9. Typical Steel Containment Vessels • BWR Mark II (Shown) – Clas MC Typical • Nominal 45 psi • Removable Head • Suppression pool below • BWR Mark III (Not Shown) – May be MC or CC • Large vessel with internal drywell • Suppression pool internal around drywell

  10. Typical Concrete Containment • Concrete Structure with steel liner • Concrete provides structural element – Class CC • Steel liner provides leak tightness – Class MC

  11. Typical Concrete Containment • Post-Tensioned Concrete Containment • Concrete is kept under compression by a system of steel tendons • Tendon system and rebar are Class CC.

  12. Provisions for Containment Inspections and Testing • 10 CFR 50 - GDC 53 – Containments shall be designed to permit • Appropriate periodic inspection of all important areas, such as penetrations • An appropriate surveillance program • Periodic testing at containment design pressure of the leak tightness of penetrations

  13. Philosophy of Containment Examination • ASME IWE and IWL define requirements for containment examination • Preservice • Inservice • Requirements based on Industry Experience and Environmental Conditions • Visual Examination of Containment • Testing for Tendons • Pressure / Leakage Testing per 10 CFR App J

  14. History of Code Requirements • IWE 1st published 1981 (Class MC Components) • Weld Based Examinations • Very similar to rules for Class 1 and 2 nuclear components. • Subsequently addressed general degradation of surface areas • Incorporated by rulemaking (10 CFR 50.55a) in 1996 • Required all containments to be treated as MC or CC • Included conditions for use

  15. History of Code Requirements • IWL 1st published 1988 (Class CC Components) • Provided rules for examination of concrete surfaces • Similar to regulatory requirements already in Regulatory Guides 1.35 and 1.35.1 • Regulatory Guides only required for post tensioned containments • Incorporated by rulemaking (10 CFR 50.55a) in 1996 • IWL replaced use of the Regulatory Guides • Transition period was allowed for plants using regulatory guides • Applicable to ALL concrete containments

  16. Current Regulatory Requirements • 10 CFR 50.55a • Incorporates ASME B&PV Code Section XI by reference with conditions • References ASME Section XI Sub-Section IWE for Class MC containments and Liners of Class CC containments • References ASME Section XI Sub-Section IWL for Class CC containments

  17. Containment Leak Testing • 10 CFR 50 – Appendix J • Periodic testing of containment vessel and penetrations • Type A tests – Integrated Leak Rate Test • Type B and C tests – Local Leak Rate Tests

  18. IWE Examinations IWE-1100 SCOPE • This Subsection provides requirements for inservice inspection of Class MC pressure retaining components and their integral attachments, and of metallic shell and penetration liners of Class CC pressure retaining components and their integral attachments in light-water cooled plants.

  19. IWE Examinations • Exempted Components • Components outside the boundaries of the containment system • Embedded or inaccessible portions of containment (with limitations on what modifications to plant can embed) • Piping, pumps, and valves (examined per either IWB or IWC)

  20. IWE Examinations • General Schedule for Inservice • 10 year inspection interval • Divided into 3 inspection periods (3 or 4 years) • Provisions for shifting interval (and one of the periods) by one year • Preservice (in general) • Exam conducted prior to placing component inservice • Includes repair or replacement • Same exam as required for periodic inservice exam

  21. IWE Examination Tables

  22. IWE Examination Tables

  23. IWE Details • Category E-A Containment Surfaces • E1.11 – Accessible Surfaces • General Visual Each Period. • Includes Bolted Connections – VT-3 per 10 CFR 50.55a • E1.12 – Wetted Surfaces of Submerged Areas • General Visual Each Interval • VT-3 per 10 CFR 50.55a • E1.20 – BWR Vent System (Mark I) • General Visual Each Interval • VT-3 per 10 CFR 50.55a • E1.30 – Moisture Barriers • General Visual Each Period

  24. IWE Details – Moisture Barriers

  25. IWE Details • Category E-C Augmented Examination • Applicable to areas subject to accelerated degradation or with previously noted degradation • E4.11 – Visible Surfaces • Detailed Visual Each Period. • VT-1 per 10 CFR 50.55a • E4.12 – Surface Area Grid • Ultrasonic Thickness Measurement (UT) Each Period

  26. IWL Examinations IWL-1100 SCOPE • This Subsection provides requirements for preservice examination, inservice inspection, and repair/replacement activities of reinforced concrete and the post-tensioning systems of Class CC components, herein referred to as concrete containments as defined in CC-1000 {Section III Design Code}.

  27. IWL Examinations • Exempted Components • Steel portions not backed by concrete • Shell metallic liners • Penetration liners • Inaccessible tendon end anchorages (with limitations) • Concrete surfaces covered by the liner, foundation material, or backfill or otherwise obstructed. (Aging concerns for buried concrete addressed in later editions of code.)

  28. IWL Examinations • General Schedule for Inservice Examination • 1, 3, and 5 years following Structural Integrity Test (SIT) • Within 6 months on either side of anniversary • Total inspection window of 1 year • 10 years after SIT and every 5 years thereafter • Within 1 year on either side of anniversary • Total inspection window of 2 years • 1 year plus or minus 3 months for concrete repairs • Preservice • Similar to IWE • Unique role of RPE

  29. IWL Examinations Two Major Divisions • Category L-A – Concrete Surfaces • All concrete containments • Category L-B – Unbonded Post-Tensioning System • Post tension design only • Tendons divided by type • Separate population for tendons impacted by repairs • Provisions for sites with multiple plants / units

  30. IWL Examination Tables

  31. IWL Details • Category L-A Concrete Surfaces • L1.11 – All Accessible Areas • General Visual Each Inspection to identify suspect areas • Resolution per RPE • L1.12 – Suspect Areas • Detailed Visual • Up close exam to determine if the area is a problem • Performed by or under the direction of a Registered Professional Engineer

  32. IWL Details • Category L-B Unbonded Post-Tensioning Systems • Sample Size • Sample of Tendons • 4 % of Each Type • Minimum of 4 and Maximum of 10 • Reduced sample for good inspection history • 2 % of Each Type • Minimum of 3 and Maximum of 5 • Separate population with reduced sample size for tendons affected by repair

  33. Overview of Post-Tension Containment

  34. Parts of a Tendon Anchorage

  35. Exposed Tendon Anchorage

  36. Uninstalled Tendon

  37. Parts of a Tendon Anchorage

  38. IWL Details • L2.10 – Tendon • Tendon Force / Elongation Test • Hydraulic Ram connected to end of tendon • Load cell measures force needed to lift tendon off of the shims • Common Tendon • One tendon is measured in each inspection • Results trended to ensure tendon stress remains above the minimum needed by design for life of the plant

  39. IWL Details • L2.20 – Wire or Strand • Destructive sample of one wire (typical tendon up to 186 wires) from one tendon of each type – NOT the common tendon • Visual exam for entire length • Sample from each end, the middle and area of most severe degradation tested for • Yield Strength, • Ultimate Strength, and • Elongation

  40. IWL Details • L2.30 – Anchorage Hardware and Surrounding Concrete • Detailed Visual – Entire Sample Population • Includes: • bearing plates, • anchor heads, • wedges, • buttonheads, • shims, and • concrete extending 2 feet from edge of the bearing plate.

  41. IWL Details • L2.40 – Corrosion Protection Medium • Sample from each end of each examined tendon • Chemical analysis for: • Water content, • Water soluble chlorides, nitrates, and sulfides • Reserve Alkalinity (expressed as milligrams of Potassium Hydroxide) • L2.50 – Free Water • The amount of any free water (if any) contained in the tendon cap is documented and analyzed to determine pH.

  42. IWL Examinations • Additional 10 CFR 50.55a exam: • Grease caps that are accessible must be visually examined to detect grease leakage or grease cap deformations. • Grease caps must be removed for this examination when there is evidence of grease cap deformation that indicates deterioration of anchorage hardware

  43. Additional 10 CFR 50.55a Requirements • The licensee shall evaluate the acceptability of inaccessible areas when conditions exist in accessible areas that could indicate the presence of or result in degradation to such inaccessible areas. • Reporting Requirements • Other provisions

  44. Objectives • State the purpose of containment vessel as used at commercial nuclear power plants in the US • Describe the general types of containment vessels currently used in the US commercial nuclear power industry. • State the difference between Class MC and Class CC components. • State the regulations requiring inservice inspection of nuclear containment buildings.

  45. Enabling Objectives (cont) • Be able to state the section of ASME Code providing requirements for inservice inspection of Class CC components of nuclear containment vessels. • Discuss the type and frequency of inservice examinations for nuclear power plant containment vessels.

  46. References • 10 CFR 50.55a • ASME B&PV Code Section XI, Subsections IWE and IWL, 2004 Edition • Rao, K. R. (editor), Companion Guide to the ASME Boiler and Pressure Vessel Code, 3rd Edition • EPRI TM-102C

  47. Questions ?