1 / 6

1-Shot Test Beam

1-Shot Test Beam. CERN CMS: M.Huhtinen, R.Hammarstrom, A.Macpherson CERN ATLAS, PS, Karlsruhe CMS. Overview Simulate conditions of asynchronous beam abort  Consequences to the tracker? Status Report beam conditions tests mechanics signal driving readout

lucien
Download Presentation

1-Shot Test Beam

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 1-Shot Test Beam CERN CMS: M.Huhtinen, R.Hammarstrom, A.Macpherson CERN ATLAS, PS, Karlsruhe CMS • Overview Simulate conditions of asynchronous beam abort  Consequences to the tracker? • Status Report • beam conditions • tests mechanics signal driving readout Date around PS MD on 16th of October Duration: 8 hours

  2. 3cm 10cm Beam Conditions 102mm2 x 1mm 11C total proton fluence: ~2.6 x 1011 per shot fast extraction: 36.6ns-pulses (separated by 262ns)  best simulation that can be done would be double shot done in same supercycle as slow extraction  1-shot tests in conjuction with other east hall beam tests (!)

  3. Tests 1st carrier: sensor + hybrid 2nd carrier: sensor + good TEC module 3rd carrier: sensor + KA prototype TEC module Testprogramm with last module shots with ... • LV off, HV off • LV on, HV off • LV off, HV on • LV on, HV on (increase risk of damage) • during ~30 consecutive shots: ramp HV (0..100V in 20V-steps and 100..400V in 50V-steps) • module still alive?

  4. Mechanics flexible mounting of module fittings realized with long holes  vertical tilting and horizontal movement of module possible  module‘s position can be adjusted to changing beam positions

  5. Signal Driving • lab tests performed with short pulsed LED signals and minisensors • signal driving over long distances (~30m) with resolution of 1Üs • rise and fall times of leakage current and AC-DC voltage: 2 and 14Üs • time resolution sufficient! Readout 15 parameters in fully populated device carrier • full sized Sensor • Vbias • Ileak • VAC-DC (3 groups) • IDC-biasresistor (3 groups) • Iguard • TEC Module • Vbias • Ileak • V,I125 • V,I250 26+xscope- and 12+yFADC channels avaliable (x,yS0... hopefully!)  at least 2 different sampling times possible (500ns, 10Üs, ...?)

  6. APV readout • APV readout done optically (thanks to Jan Troska) • I2C transfer over ~30m successfully tested • total readout chain is now being setup and tested • readout software has to be done Conclusion • beam setup ok • mechanics ok • signal aquisition and monitoring nearly finished • testing of readout chain in progress • we expect to be ready in time!

More Related