CHE 185 – PROCESS CONTROL AND DYNAMICS

keiran avatar
15 slides · 403 Views · 170 likes · Jul 29, 2014

CHE 185 – PROCESS CONTROL AND DYNAMICS. WORKSHOP 2. P-only control of tank level. OBJECTIVES: 1. Understand the concept of closed loop feedback control (in contrast to open loop). 2. See the effects of controller gain on its performance (Define performance) . P-only control of tank level.

CHE 185 – PROCESS CONTROL AND DYNAMICS - slide 1
01 / 15CHE 185 – PROCESS CONTROL AND DYNAMICS
1 / 17

Download Presentation

CHE 185 – PROCESS CONTROL AND DYNAMICS
An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

More Related Content

Presentation Transcript
  1. CHE 185 – PROCESS CONTROL AND DYNAMICS WORKSHOP 2

  2. P-only control of tank level • OBJECTIVES: • 1. Understand the concept of closed loop feedback control (in contrast to open loop). • 2. See the effects of controller gain on its performance (Define performance) .

  3. P-only control of tank level • OBJECTIVES: • 3. Realize the difference between set point tracking and disturbance rejection controls (show response curves for each) • 4. Predict the steady state error of the P-only control, and understand the existence of it for P-only control

  4. P-only control of tank level • OBJECTIVES: • 5. Understand what proportional band is. • overall objective is to maintain inventory; tank-filling operation is to maintain constant level; transmitter, control valve, and controller are the devices to achieve that objective.

  5. P-Only Control of Tank Level Worksheet

  6. P-Only Control of Tank Level Worksheet

  7. P-Only Control of Tank Level Worksheet

  8. TYPICAL RESULTS • Fit a FOPDT dynamic model to the CO to PV (cause and effect) step test data CO = controller output; PV = measured process variable (level in the tank)

  9. TYPICAL RESULTS • Fit a FOPDT dynamic model to the CO to PV

  10. TYPICAL RESULTS • 60%  68% step in Controller Output

  11. TYPICAL RESULTS • 60%  68% step in Controller Output

  12. TYPICAL RESULTS • 60%  68% step in Controller Output

  13. TYPICAL RESULTS • ACTIVATING THE CONTROLLER - Click the level controller icon (LC), switch from Manual Mode to PID, enter your SP, CObias and Kc values. Switch integral to ‘off: Integral Mode’. Derivative Mode should also be off.

  14. TYPICAL RESULTS

  15. TYPICAL RESULTS