1 / 7

SENSOR MEASUREMENTS

SENSOR MEASUREMENTS. Probe Station: IV, CV, IIV, etc. Want to: make measurements as function of different vacuum levels, temperatures and bias voltages. Need a new setup…. (from Radia&Nabil’s talk). HV/HV SYSTEM DESIGN. BB#1. A,V. CIRCUIT KEY. VACUUM ELECTRONIC COOLING GAS OPTICAL.

elom
Download Presentation

SENSOR MEASUREMENTS

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. SENSOR MEASUREMENTS • Probe Station: IV, CV, IIV, etc. • Want to: make measurements as function of different vacuum levels, temperatures and bias voltages. • Need a new setup… (from Radia&Nabil’s talk) R. Mountain, Syracuse University VACUUM Scrapbook 2006 -1-

  2. HV/HV SYSTEM DESIGN BB#1 A,V CIRCUIT KEY VACUUM ELECTRONIC COOLING GAS OPTICAL • PURPOSE Sensor characterization at different vacuum levels, temps, and bias voltages • DESIGN PARAMETERS Pressure: 10-1 ~ 10-4 mbar Temp ~ -7 deg.C Est. SQ » 10 mbar∙ℓ/hr (»100 NA/hr) F/T:F [HN] F/T:D [HN] ZLR ZLR COLD-CATHODE GAUGE CF6 CF6 ? RTD P LFb-16 VACUUM IR WINDOW CF2.75 SILICON [FX] HX VACUUM CHAMBER V1 LFc-16 CF4.5 CHILLER [HN] [HN] CLEANROOM PC “PIXEL” CF6 CF2.75 V3 F/T:3xBNC,1xSHV VIBR. ISOL. V2 [TE] F/T COAX BB#2 (SS LINE) F/T TRIAX CF4.5 RS232 PURGE VALVE [NP] VACUUM GAUGE CONTROLLER FLOW METER KEITHLEY 237 CF4.5 TURBO PUMP REG. ISO-KF-NW25 CONVECTION GAUGE DRY SCROLL PUMP DRY AIR, N2 MINI-PUMPING STATION • VACUUM PUMP Need: Sp>S, where S = SQ/ P» 40 ℓ/s Pump-down time <15 min (est.) • VACUUM LINE & GAUGES Keep conductance high (tube: C~D3/L) Gauge pair, with overlapping range • VACUUM CHAMBER Our design, fabrication, comm. parts • SENSOR MEASUREMENT Adapt existing IV setup • COOLING Chilled fluid flow, single phase; Interior or exterior (either possible) R. Mountain, Syracuse University VACUUM Scrapbook 2006 -2-

  3. DESIGN R. Mountain, Syracuse University VACUUM Scrapbook 2006 -3-

  4. VESSEL CONSTRUCTION (PIX) R. Mountain, Syracuse University VACUUM Scrapbook 2006 -4-

  5. BACK COVER CONSTRUCTION (PIX) R. Mountain, Syracuse University VACUUM Scrapbook 2006 -5-

  6. FRONT COVER CONSTRUCTION (PIX) R. Mountain, Syracuse University VACUUM Scrapbook 2006 -6-

  7. HV/HV SYSTEM DESIGN BB#1 A,V CIRCUIT KEY VACUUM ELECTRONIC COOLING GAS OPTICAL • PURPOSE Sensor characterization at different vacuum levels and bias voltages • DESIGN PARAMETERS Pressure: 10-1 ~ 10-4 mbar Temp ~ -7 deg.C Est. SQ » 10 mbar∙ℓ/hr (»100 NA/hr) F/T:F [HN] F/T:D [HN] ZLR ZLR COLD-CATHODE GAUGE CF6 CF6 CF6 ? RTD P LFb-16 VACUUM IR WINDOW CF2.75 SILICON [FX] HX VACUUM CHAMBER V1 LFc-16 CF4.5 CHILLER [HN] [HN] CLEANROOM PC “PIXEL” CF6 ZLR CF2.75 V3 F/T:3xBNC,1xSHV VIBR. ISOL. V2 [TE] F/T COAX BB#2 (SS LINE) F/T “EXTRAS” TRIAX CF4.5 RS232 PURGE VALVE [NP] BL VACUUM GAUGE CONTROLLER CF2.75 FLOW METER ZLR CF6 KEITHLEY 237 BL CF6 CF4.5 TURBO PUMP REG. ISO-KF-NW25 “NEEDS” CONVECTION GAUGE - BOLTS DRY SCROLL PUMP DRY AIR, N2 MINI-PUMPING STATION • VACUUM PUMP Need: Sp>S, where S = SQ/ P» 40 ℓ/s Pump-down time <15 min (est.) • VACUUM LINE & GAUGES Keep conductance high (tube: C~D3/L) Gauge pair, with overlapping range • VACUUM CHAMBER Our design, fabrication, comm. parts • SENSOR MEASUREMENT Adapt existing IV setup • COOLING Chilled fluid flow, single phase; Interior or exterior (either possible) R. Mountain, Syracuse University VACUUM Scrapbook 2006 -7-

More Related