Utilizing template gauge to verify rounded marked dimensions in the H.L. Cover part. Dimensions are interrelated with radius, hindering accurate CMM measurement. Next batch will be confirmed using the new method.
E N D
Part Name –H. L. Cover(Modified)Part No- D10 174570B Slot checking Method
For rounded marked dimensions in heavy duty H L Cover part no.10 174 570B as these are radius & the dimensions are interrelated with radius it is not possible to measure on CMM properly . For next lot we will confirm it by using template gauge