Conclusion on cables for 280 mbits s
Download
1 / 2

CONCLUSION ON CABLES FOR 280 MBITS/S - PowerPoint PPT Presentation


  • 121 Views
  • Uploaded on

CONCLUSION ON CABLES FOR 280 MBITS/S. SPD cables: 24-25 m length: receiver side simple termination. Compensation on driver side (R+L) Use of 3.3->3.6 Volts +/or pull up current to increase signal margin (165mv-> 200 mv)

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about 'CONCLUSION ON CABLES FOR 280 MBITS/S' - babu


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
Conclusion on cables for 280 mbits s
CONCLUSION ON CABLES FOR 280 MBITS/S

SPD cables:

24-25 m length: receiver side simple termination. Compensation on driver side (R+L) Use of 3.3->3.6 Volts +/or pull up current to increase signal margin (165mv-> 200 mv)

To control skew : first choice, Cat5 rigid; 100 m cut in 4 “identical 25m cables”. Or cat 6 cut in middle but problems at the end-> add short patch cables (8 euros each?). Anyhow problem on FE side Drawing of solution needed=> Orsay? (information sent from Orsay to David on 13/12/03 )

Upper SPD cables shorter => Annecy defines minimum length? If possible is it better to make them shorter by exactly 50ns?(about 11meter) Smaller compensation but still skew problem=> 4 cables identical or cut each cable in half and cross.

Jacques Lefrancois


Trigger cables:

Between crates of one rack: length 1-2 meter => use standard patch cables Cat 5 may have too much skew => characterize cat6 commercial patch cables. (Orsay+ Barcelona or Clermont?)

Between two racks; calculate length (<4m?) Is cat 6 patch cables OK ?

Between HCAL and ECAL about 10 meters probably some “small” compensation receiver side (validation card) Skew compensation by cutting and reconnecting cable probably needed

Jacques Lefrancois