1 / 24

Edgeless detectors with CTS: the 1st year successful operation in TOTEM

Edgeless detectors with CTS: the 1st year successful operation in TOTEM. Vladimir Eremin E. Verbitskaya, I. Eremin, B. Ermolaev, N. Fadeeva, Yu. Tuboltcev, Ioffe Physical - technical institute, St. Petersburg, Russia

Download Presentation

Edgeless detectors with CTS: the 1st year successful operation in TOTEM

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Edgeless detectors with CTS: the 1st year successful operation in TOTEM Vladimir Eremin E. Verbitskaya, I. Eremin, B. Ermolaev, N. Fadeeva, Yu. Tuboltcev, Ioffe Physical - technical institute, St. Petersburg, Russia N. Egorov, S. Golubkov, K. Konkov Research Institute of material science and technology, Russia J.Buchler, K. Egger, G.Ruggiero CERN, TOTEM collaboration 19-th RD50 meeting, CERN, November 21 – 23, 2011

  2. Experimental layout Leading Protons detectors at 147,220m from the IP IP5 Leading Protons detectors at 147,220m from the IP T2 CMS T1 Inselastic Telescopes T1 T2 V. Eremin, 19-th RD50 meeting, CERN, November 21 – 23, 2011

  3. Voltage terminating structure (VTS) Voltage terminating structure (VTS) Voltage terminating structure (VTS) (floating rings) (floating rings) (floating rings) V= V= V= V V V V=0 V=0 V=0 b b b Sensitive area (p Sensitive area (p Sensitive area (p ) ) ) + + + d d d (n+) (n+) (n+) > 2d (>600 > 2d (>600 > 2d (>600 µ µ µ ) ) ) V V V b b b Voltage Terminating Structure sensitive part Cut edge (highly damaged surface) >1mm (Non Sensitive) Regular planar detectors 1. G. Ruggiero et al. IEEE Trans. Nucl. Sci. 52 (2005) 1899. 2. E. Noschis et al. Nucl. Instr. and Meth. A 563 (2006) 41. V. Eremin, 19-th RD50 meeting, CERN, November 21 – 23, 2011

  4. Requirements for TOTEM Edgeless Strip Detectors • The production yield providing fabrication hundreds of the detectors • Low strip capacitance and current for appropriate signal to noise ratio • Stable properties of the sensitive edge along the years detectors operation. The choices: • N-on–P planar • 3D technology V. Eremin, 19-th RD50 meeting, CERN, November 21 – 23, 2011

  5. Prehistory Z. Li et al., IEEE Trans. Nucl. Sci. NS-49 (2002) 1040-1046 • I-V improvement: • Dicing from the back side • One day “annealing” at RT V. Eremin, 19-th RD50 meeting, CERN, November 21 – 23, 2011

  6. 3D active edge detectors C. Da Via et al., NIM A587 (2008) 243-249 • Main features of design: • p+ and n+ through entire bulk • p+ active edge • collection distance ≤ 50 mm  fast response  higher electric field due to cylindrical geometry radiation hardness but • Complicated technology – low yield V. Eremin, 19-th RD50 meeting, CERN, November 21 – 23, 2011

  7. Planar approaches Sensitive area Voltage terminating rings The cut Insulating cut (exploited in silicon power devises – bevel etched devises) Conductive cut Passivated cut V. Eremin, 19-th RD50 meeting, CERN, November 21 – 23, 2011

  8. EDL detector with passivated cut VTS at the cut Voltage Terminating Rings (floating) SiO2 passivated cut Sensitive area Non-sensitive corner Complicate technology Low operational voltage Low operational fluence Low production yield V. Eremin, 19-th RD50 meeting, CERN, November 21 – 23, 2011

  9. Detector with CTS(TOTEM edgeless design) Current terminating ring Clean-up ring Sensitive area Voltage terminating rings • Effect of the Current Terminating Structure • The potential distribution along the cut similar to the potential in the bulk • The current of CTR: Injected Ohmic current along the cut • The current of CUR: Diffusion current from the cut to the bulk • The current of sensitive area: mainly the bulk generated current • No potential drop along the CTS rings V. Eremin, 19-th RD50 meeting, CERN, November 21 – 23, 2011

  10. - E(z) Surface ohmic current z x + Potential at the cut Electric field at the cut X X X Conductive cut – the main part of EDL detectors Damaged cut surface has high concentration of defect levels and high recombination rate Potential in the bulk p+ E(z) Ex – const Ex_bulk - linear n+ V. Eremin, 19-th RD50 meeting, CERN, November 21 – 23, 2011

  11. Δ=50µm Current at the detector sensitive area(diffusion model) Hole current Distance from the cut Ibulk= Igen exp(-Δ/Ldif)= Igen*2.3e5 at : ICTR= 1e-3A; Ibulk= 2.3e-8A at : D= 16cm; tdr= 10ns V. Eremin, 19-th RD50 meeting, CERN, November 21 – 23, 2011

  12. Final design VTS CTS • Very High Resistivity Si n-type <111>, 300um thick, Vdep ~20V • Standard planar technology fabrication • AC coupled strip (punch-through) • Single sided detector, 512 microstrips (pitch 66um) • strips at 45° from the “sensitive” edge • Voltage Terminating Structure on non sensitive edges • Current Terminating Structure on sensitive edges Pitch adapter on detector VFAT / APV25 compatible ~50 m Only 50m from end of strip to end of sensor!!! V. Eremin, 19-th RD50 meeting, CERN, November 21 – 23, 2011

  13. Experimental I-V characteristics 23nA (Icut) + 57nA(Ibulk) = 80nA Good agreement with the predictions ! V. Eremin, 19-th RD50 meeting, CERN, November 21 – 23, 2011

  14. Recent experimental results on CCE in p-on-n edgeless detectors with CTS Efficiency of CTS detector at the sensitive edge Physical edge G. Ruggiero et al. Planar Edgeless Silicon Detectors for the TOTEM Experiment. Pres. 8th Intern.Conf. on Position Sensitive Detectors (PSD8), Glasgow, Sept 1-5, 2008, Nucl. Instr. and Meth. A (in press). V. Eremin, 19-th RD50 meeting, CERN, November 21 – 23, 2011

  15. The TOTEM Roman Pot Silicon Sensor n-Si, r ~ 20 k·cm Vfd: ~20 V; 512 strips, 66 µm pitch, Voper up to 400V V. Eremin, 19-th RD50 meeting, CERN, November 21 – 23, 2011

  16. TOTEM Edgeless Detectors Technology Monitoring Statistics over 204 TOTEM edgeless strip detectors at 100V n-Si, r ~ 20 k·cm Vfd: ~20 V; 512 strips with a pitch of 66 µm Detector area 10cm2 Averaged current density: 12nA/cm2/300μ V. Eremin, 19-th RD50 meeting, CERN, November 21 – 23, 2011

  17. The Hybrid Kapton Flex PCB VFAT chip CE07 support plate Si microstrip edgeless detector CE07 side bar with mounting holes DCU 128 channels of tracking front end with digital storage and data transmission 8 programmable trigger outputs , radiation hard design pt100 V. Eremin, 19-th RD50 meeting, CERN, November 21 – 23, 2011

  18. Detector Package 24 Detector Packages over >440m 122880 r/o channels 240 sensors (.3m2) V. Eremin, 19-th RD50 meeting, CERN, November 21 – 23, 2011

  19. Radiation hardness of the edgeless sensor with CTS Radiation hard N-on-P edgeless detectors Real, full size, devices tested Uniformly irradiation with 24 GeV protons Readout with VFAT Operating temperature: -20°C 100% Efficiency at >1x1014pcm-2 (at 500V) V. Eremin, 19-th RD50 meeting, CERN, November 21 – 23, 2011

  20. Electrical characteristics of test edgeless n-on-p detectors Pad detectors as-processed 84 samples Jmean = 30 nA/cm2 Ipad 10-4ICTR - as in p-on-n V. Eremin, 19-th RD50 meeting, CERN, November 21 – 23, 2011

  21. Current vs. fluence in n-on-p edgeless detectors with CTS • Dark current is bulk generation current • dark (pad) current is still less than CTR current • CTR current is only slightly dependent on Fp • CR currrent is affected by bulk current V. Eremin, 19-th RD50 meeting, CERN, November 21 – 23, 2011

  22. Wafer layout with N-on-P edgeless detectors Large strip EDL Baby strip EDL Test strip regular Pad EDL Pad regular Small reqular V. Eremin, 19-th RD50 meeting, CERN, November 21 – 23, 2011

  23. Summary September 2009 October 2011 • A novel approach for the edgeless detectors was developed and successfully realized in TOTEM experiment (R&D and TDR in 2004 first data taking in 2009) • The 1 year stable operation of 240 TOTEM EDL detectors proved completely the physical background of the new development and motivates to follow this line for advancing the EDL detectors radiation hardness. • The story is not over… V. Eremin, 19-th RD50 meeting, CERN, November 21 – 23, 2011

  24. Thank you for your attention

More Related