1 / 15

Morphometry BIRN Tool Dissemination

Morphometry BIRN Tool Dissemination. Morphometry BIRN: Tool Dissemination. Recommendation for MRI acquisition protocols Software Processing and Visualization Tools MRI data Tutorials. Domains for public dissemination. Morphometry BIRN: Tool Dissemination.

tuari
Download Presentation

Morphometry BIRN Tool Dissemination

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Morphometry BIRN Tool Dissemination

  2. Morphometry BIRN:Tool Dissemination • Recommendation for MRI acquisition protocols • Software Processing and Visualization Tools • MRI data • Tutorials Domains for public dissemination

  3. Morphometry BIRN:Tool Dissemination Recommendation for MRI acquisition protocols • Scanner Upgrade Calibration Protocol: http://www.na-mic.org/Wiki/index.php/MGH-BWH_Mini-BIRN_Standard_Upgrade_Protocol • GE/Siemens diffusion MRI acquisition with phase maps Software Processing and Visualization Tools: • Gradient non-linearities distortion correction code • Distortion correction code for DTI (Bo and eddy currents effects) • Tool for de-identifying structural MRI • Freesurfer: tool for automated segmentation of neuroanatomical structures • LDMM: tool for shape analyses • LONI Pipeline: tool for controlling processing workflows • 3D Slicer: visualization tool MRI data: • Open Access Structural Imaging Series • Multi-site mBIRN calibration study (5 subjects, 5 sites, 2 visits) • DTI calibration data (2 subjects scanned multiple times) Tutorials: • 3D Slicer and Freesufer (Thu Oct 20)

  4. Morphometry BIRN:Tool Dissemination Recommendation for MRI acquisition protocols • Scanner Upgrade Calibration Protocol: http://www.na-mic.org/Wiki/index.php/MGH-BWH_Mini-BIRN_Standard_Upgrade_Protocol • GE/Siemens diffusion MRI acquisition with phase maps Software Processing and Visualization Tools • Gradient non-linearities distortion correction code • Distortion correction code for DTI (Bo and eddy currents effects) • Tool for de-identifying structural MRI • Freesurfer: tool for automated segmentation of neuroanatomical structures • LDMM: tool for shape analyses • LONI Pipeline: tool for controlling processing workflows • 3D Slicer: visualization tool MRI data: • Open Access Structural Imaging Series • Multi-site mBIRN calibration study (5 subjects, 5 sites, 2 visits) • DTI calibration data (2 subjects scanned multiple times) Tutorials: • 3D Slicer and Freesufer (Thu Oct 20)

  5. Morphometry BIRN:gradient unwarping code Siemens Sonata (1.5T) Uncorrected Images Corrected Images Siemens AC88 (7T)

  6. Morphometry BIRN:Tool Dissemination Recommendation for MRI acquisition protocols • Scanner Upgrade Calibration Protocol: http://www.na-mic.org/Wiki/index.php/MGH-BWH_Mini-BIRN_Standard_Upgrade_Protocol • GE/Siemens diffusion MRI acquisition with phase maps Software Processing and Visualization Tools • Gradient non-linearities distortion correction code • Distortion correction code for DTI (Bo and eddy currents effects) • Tool for de-identifying structural MRI • Freesurfer: tool for automated segmentation of neuroanatomical structures • LDMM: tool for shape analyses • LONI Pipeline: tool for controlling processing workflows • 3D Slicer: visualization tool MRI data: • Open Access Structural Imaging Series • Multi-site mBIRN calibration study (5 subjects, 5 sites, 2 visits) • DTI calibration data (2 subjects scanned multiple times) Tutorials: • 3D Slicer and Freesufer (Thu Oct 20)

  7. Morphometry BIRN:DTI correction code Distortion corrections with phase-maps for each diffusion-encoding direction http://wiki.na-mic.org/Wiki/index.php/Mbirn:_B0_and_eddy_current_correction_code_for_diffusion_MRI

  8. Morphometry BIRN:Tool Dissemination Recommendation for MRI acquisition protocols • Scanner Upgrade Calibration Protocol: http://www.na-mic.org/Wiki/index.php/MGH-BWH_Mini-BIRN_Standard_Upgrade_Protocol • GE/Siemens diffusion MRI acquisition with phase maps Software Processing and Visualization Tools • Gradient non-linearities distortion correction code • Distortion correction code for DTI (Bo and eddy currents effects) • Tool for de-identifying structural MRI • Freesurfer: tool for automated segmentation of neuroanatomical structures • LDMM: tool for shape analyses • LONI Pipeline: tool for controlling processing workflows • 3D Slicer: visualization tool MRI data: • Open Access Structural Imaging Series • Multi-site mBIRN calibration study (5 subjects, 5 sites, 2 visits) • DTI calibration data (2 subjects scanned multiple times) Tutorials: • 3D Slicer and Freesufer (Thu Oct 20)

  9. Morphometry BIRN:defacing code http://wiki.na-mic.org/Wiki/index.php/Mbirn:_Defacer_for_structural_MRI

  10. Morphometry BIRN:Tool Dissemination Recommendation for MRI acquisition protocols • Scanner Upgrade Calibration Protocol: http://www.na-mic.org/Wiki/index.php/MGH-BWH_Mini-BIRN_Standard_Upgrade_Protocol • GE/Siemens diffusion MRI acquisition with phase maps Software Processing and Visualization Tools • Gradient non-linearities distortion correction code • Distortion correction code for DTI (Bo and eddy currents effects) • Tool for de-identifying structural MRI • Freesurfer: tool for automated segmentation of neuroanatomical structures • LDMM: tool for shape analyses • LONI Pipeline: tool for controlling processing workflows • 3D Slicer: visualization tool MRI data: • Open Access Structural Imaging Series • Multi-site mBIRN calibration study (5 subjects, 5 sites, 2 visits) • DTI calibration data (2 subjects scanned multiple times) Tutorials: • 3D Slicer and Freesufer (Thu Oct 20)

  11. Morphometry BIRN:supported tools Freesurfer (MGH) (surfer.nmr.mgh.harvard.edu) 3D Slicer (BWH) (www.slicer.org ) LDMM JHU (www.cis.jhu.edu/software/ldmm ) LONI Pipeline (UCLA) (www.loni.ucla.edu )

  12. Morphometry BIRN:Tool Dissemination Recommendation for MRI acquisition protocols • Scanner Upgrade Calibration Protocol: http://www.na-mic.org/Wiki/index.php/MGH-BWH_Mini-BIRN_Standard_Upgrade_Protocol • GE/Siemens diffusion MRI acquisition with phase maps Software Processing and Visualization Tools • Gradient non-linearities distortion correction code • Distortion correction code for DTI (Bo and eddy currents effects) • Tool for de-identifying structural MRI • Freesurfer: tool for automated segmentation of neuroanatomical structures • LDMM: tool for shape analyses • LONI Pipeline: tool for controlling processing workflows • 3D Slicer: visualization tool MRI data • Open Access Structural Imaging Series • Multi-site mBIRN calibration study (5 subjects, 5 sites, 2 visits) • DTI calibration data (2 subjects scanned multiple times) Tutorials: • 3D Slicer and Freesufer (Thu Oct 20)

  13. Open Access Structural Imaging Series project • www.oasis-brains.org • Rich structural & functional MRI dataset (WashU) • Open access user agreement means free & unrestricted use of data • Part I (November, 2005): 400 cross-sectional acquisitions across lifespan, including 100 demented individuals • Extensions throughout 2006: longitudinal, DTI, fMRI, calibration…

  14. The OASIS project Data set includes 3-4 raw T1-weighted scan, averaged, atlas- registered, and FSL-segmented. Data can be searched, downloaded, and viewed via the web site.

  15. Morphometry BIRN:Tool Dissemination Recommendation for MRI acquisition protocols • Scanner Upgrade Calibration Protocol: http://www.na-mic.org/Wiki/index.php/MGH-BWH_Mini-BIRN_Standard_Upgrade_Protocol • GE/Siemens diffusion MRI acquisition with phase maps Software Processing and Visualization Tools • Gradient non-linearities distortion correction code • Distortion correction code for DTI (Bo and eddy currents effects) • Tool for de-identifying structural MRI • Freesurfer: tool for automated segmentation of neuroanatomical structures • LDMM: tool for shape analyses • LONI Pipeline: tool for controlling processing workflows • 3D Slicer: visualization tool MRI data • Open Access Structural Imaging Series • Multi-site mBIRN calibration study (5 subjects, 5 sites, 2 visits) • DTI calibration data (2 subjects scanned multiple times) Tutorials • 3D Slicer and Freesufer (Thu Oct 20)

More Related