Voltage/Current Presence Check

Effective November 1, 2003, the Voltage and Current (V&I) presence check will not be performed in MV90 due to granted exemptions until March 2004. Numerous false meter readings have been reported due to limitations in the existing algorithm. A more reliable V&I checking method is being developed. Checks should only be done for compliant meters using MVStar, calculating average values over a clocked hour interval. Validation criteria are established for average voltage and current values, ensuring accurate performance.

tana-booker
Download Presentation

Voltage/Current Presence Check

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Voltage/Current Presence Check Update

  2. Voltage and Current Presence Check • Effective Nov.1, 2003 V&I presence check is not being performed in MV90 • Exemption granted to turn off V&I checking until March 2004 • 100’s of false MTR’s due to design limitations of algorithm • More reliable and robust V&I checking being developed

  3. Voltage and Current Presence Check • Perform the voltage and current presence checks only for compliant meters • Perform the voltage and current presence checks in MVStar • Perform the voltage and current presence check over a clocked hour interval • Calculate the average value for UOM code 7 (V2H) • Calculate the average value for UOM code 10 (I2H) • Pass validation if average value is less than 17425 (132 V) and greater than 10000 (100V) and pass validation if average value equals zero. • Pass validation if average value is less than 56.25 (7.5 A). • Pass validation for each channel if the percent difference is less than 5% and greater than -5% of the calculated average value of code 7. • Pass validation for each channel if the percent difference is less than 50% and greater than -50% of the calculated average value of code 10. • Fail validation if UOM code 10 is greater than zero and UOM code 7 equals zero

More Related