1 / 22

Presentation of

Presentation of. ELIS PLZEŇ a. s. The Czech Republic. Es 90349K/b. Company profile. ELIS PLZE Ň a. s. leader in development and production of flow meters of liquids in the Czech Republic all products are from own development product range: ultrasonic flow meters of type SONOELIS

susan
Download Presentation

Presentation of

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Presentation of ELIS PLZEŇ a. s. The Czech Republic Es 90349K/b

  2. Company profile • ELIS PLZEŇ a. s. • leader in development and production of flow meters of liquids in the Czech Republic • all products are from own development • product range: • ultrasonic flow meters of type SONOELIS • ultrasonic battery powered water meters of type FLOMIC • ultrasonic battery powered flow meters of type FLOMIC • induction flow meters of type FLONET • heat meters in water of type SONOTHERM • heat meters in steam of type STEAMTHERM • ultrasonic level meters of type LEVELIS

  3. Company history • 1990 ELIS PLZEŇ Company founded • 1991 New Heat meters in water launched • 1991 ELIS PLZEŇ transformed to Limited company • 1993 New Heat meters in steam launched • 1993 New testing center build up for metrological verification and calibration of calorimetric counters for heat meters • 1995 New ultrasonic flow meters launched

  4. 1997 ELIS PLZEŇ transformed to Join stock company • 1998 New electromagnetic flow meters launched • 1998 New testing center built up for metrological verification and calibration for flow meters in sizes DN 25 to DN 200 (1 inch to8 inches) • 2002 New testing center build up for metrological verification and calibration for sizes DN 15 to DN 40 (1/2" to 1 ½") • 2003 New ultrasonic water meters with battery supply launched

  5. 2005 Company certified ISO 9001 • 2006 Enlargement of testing center for new test rigs for metrological verification and calibration of flow meters,calorimetric counters for heat meters and temperaturesensors • 2006 New ultrasonic flow meters with battery supply for big dimension DN 200 to DN 2000 (8" to 80") launched • 2006 New high pressure ultrasonic flow meters launched up to160 bar(up to 2320 psi) • 2007 New ultrasonic levelmeters LEVELIS launched

  6. GENERAL MEETING SUPERVISORY BOARD BOARD OF DIRECTORS GENERAL MANAGER OFFICE OF GENERAL DIRECTOR REPS OF MANAGEMENT SALES DEP TECHNICAL DEP QUALITY DEP PRODUCT DEP MAINTENANCE INSPECT METROLOGY DEP ACCOUNT AND HUMEN RESOURC DEP ORGANIZATION OF ELIS PLZEN a.s.

  7. Induction flow meter FLONET FN 20XX • Application: precise measurement of flow of water and otherconductiveliquids • Suitable for pipes: DN 6 to DN 1200 (¼" to 48") • Wide selection of pressure range:6 to 40 bar • Lining:Hard, soft, special rubber, Teflon • Liquid temperature scale:0 to 150°C • High accuracy: • 0,2% in range 10 to 100% qs 0,5 in range 5 to 100% qs • Communication interface:RS 485

  8. Induction flow meter FLONET FF10XX • Application: precise measurement of flow of conductive liquids in food industry • Suitable for pipes: DN 10 to DN 100 (¼" to 4") • Pressure range: 10 bar • Design of sensor:stainless steel • Type of connection: Tri Clamp or Food screwed joint • Lining: Teflon • Liquid temperature scale:0to 150°C • High accuracy: 0,5% in range 5 to 100% qs • Communication interface:RS 485 communication line

  9. Induction flow meter FLONET FR 10XX • Application: precise measurement of flow of waterand other conductive liquids • Suitablefor pipes: DN 6 to DN 1200 (¼" to 48") • Wide selection of pressure range: 6 to 40 bar • Liquidtemperature scale:0 to 150°C • High accuracy: 0,5% in range 5 to 100% qs • Communication interface:HART or FOUNDATION FIELDBUS

  10. Induction flow meter FLONET FS 10XX • Application: precise measurement of flow of conductive liquids with very high abrasion • Suitable for pipes: DN 100 to DN 450 (4" to 18") • Pressure range:10 and 16 bar • Design of sensor:Wafer or Flanged • Lining:wear-resistant material • Liquid temperature scale:0 to 150°C • High accuracy: 0,5% in range 5 to 100% qs • Communication interface:HART protocol

  11. Ultrasonic flowmeter SONOELIS SE 40XX • Application: precise measurementof flow of various clean liquids • Suitable for pipes: DN 15 to DN 300 (1/2 inch to 12 inch) • Measuring method:transit time • Flow rate range:10 to 1000 m3/hod • Pressure range:16 or 40 bar • Liquid temperature scale:0 to 150°C • High accuracy: 0,5% in range 5 to 100% qs - model SE 406X - dual beam 1% in range 5 to 100% qs - model SE 404X - single beam • Communication interface: RS 485 communication line

  12. Ultrasonic flowmeter SONOELIS SE 401X and SONOELIS SE 402X • Application: precise measurement of flow of various clean water • Suitable for pipes: DN 200 to DN 1200 (8" to 48") • Measuring method:transit time • Pressure range: 6 to 160 bar • Liquid temperature scale:0to 150°C • High accuracy: 0,5%and better model SE 402X - dual beam SE 402X 1%and better model SE 401X – single beam SE 401X • Communication interface: RS 485 communication line

  13. Ultrasonic flowmeter SONOELIS SE 80XX • Application: precise measurement of water and clean liquids in big pipelines by method of DIRECT ASSEMBLY • Suitable for pipes: DN 200 to DN 1200 (8 inch 48 inch) • Measuring method:transit time • Pressure range:up to 40 bar • Liquid temperature scale:0 to 150°C • High accuracy by theoretical calibration: 1 %and better model SE 806X – - dual beam 2 %and better model SE 804X - single beam • Communication interface: RS 485 communication line

  14. Ultrasonic watermeter FLOMIC FL 102X • Application: measurement of flow, water consumption and pressure intended for finding ofwater leakage • Suitable for sizes: DN 32 to DN 200 (1 ¼" to 8") • Rated flow range:6 to 250 m3/hour • Rated pressure: 16 bar • Measuring method: transit time • Flowratesampling period: 1 sec • Accuracy class:B as per ISO 4064-1 • Electrical outputs:pulse and current • Storage dates • Communication interface:IR, RS 232, M-Bus • Protectionclass: compactversion (IP 67) remoteversion (IP 68) Battery powered! Live of battery 8 years!

  15. Application: measurement of flow, water consumption and pressure Suitable for pipes: DN 32 to DN 300 (1 ¼" to 12") Rated flow range:0.04 to 3125 m3/hour Rated pressure:16 and 40 bar Measuring method: transit time Flowratesampling period: 1 sec Accuracy: according to EN 14154 Electrical outputs:pulse and current Data storage Communication interface: IR, RS 232, M-Bus Protectionclass: compactversion (IP 67) remoteversion (IP 68) Ultrasonic flowmeter FLOMIC FL 103X Battery powered! Live of battery 8 years!

  16. Ultrasonic flow meter FLOMIC FL 3005 • Application: precise measurement of water and cleanliquids in big pipelines by method of DIRECT ASSEMBLY • Suitable for pipes: DN 200 to DN 2000 (8" to 80") • Measuring method: single beam, transit time • Flowratesampling period: 1 sec • Pressure range:16 bar, 40 bar • Liquid temperature scale:0 to 150°C • High accuracy by theoretical calibration: 2% and better • Communication interface:IR, RS 232 Battery powered! Live time of battery 4 years!

  17. Ultrasonic flow meter FLOMIC FL 3085 • Application: measurement of flow rate and water consumption Suitable for pipes: DN 200 to DN 1200 (8" to 48") • Nominal flow range:2.3 to 20.000 m3/hour • Nominal pressure:6 to 40 bar • Measuring method:single beam, transit time • Flowratesampling period:1 sec • Battery powered:live time of battery min 4 year • Accuracy class:1%and better • Electrical outputs:pulse and current • Data storage • Communication interface:M-Bus, RS 232 Battery powered! Live time ofbattery 4 years!

  18. Ultrasonic water meter FLOMIC FL 5024 and FLOMIC FL 5044 • Application: measurement of flow, water consumptionand pressure intended for finding ofwater leakage • Suitable for sizes: DN 32 to DN 200 (1 ¼" to 8") • Measurementmethod: single beam (FL 5024) dualbeam (FL 5044 up DN 65) • Rated flow range:10 to 400 m3/hour • Rated pressure: MAP16 • Measuring method: transit time • Flowratesampling period: 1 sec • Accuracy class:according to EN 14154 • Electrical outputs:pulse and current • data storage • Communication interface: USB, RS 232, GSM module • Protectionclass: IP 68 Battery powered! Live time ofbattery 8 years!

  19. Ultrasonicflow meter FLOMIC FL 5034 and FLOMIC FL 5054 • Application: measurement of flow, water consumption and pressure • Suitable for pipes: DN 32 to DN 300 (1 ¼" to 12") • Measurementmethod: single beam (FL 5034) dualbeam (FL 5054 up DN 40) • Rated flow range:16 to 1000 m3/hour • Pressureclass: MAP 16 and MAP 40 • Measuring method: transit time • Flowratesampling period: 1 sec • Accuracy class: according to EN 14154 • Electrical outputs:pulse and current • data storage • Communication interface:USB, RS 232, GSM module • Protectionclass: IP 68 Battery powered! Live time ofbattery 8 years!

  20. Ultrasoniclevel meter LEVELIS LU-55 • Application: isused to continuouslymonitor levelheightofliqud media, sludgeorsuspensations in tanks, sumps, canals • Measurementrange:0.25 to 10m • Minimum deadzone:0.2m • Waveradiationangle:10 to 12° • Powersource:12 to 30V DC • Output: 4 to 20mA • Accuracy: 0.3% (LU - 55N - 10, LU - 55N - 6)  0.5% (LU - 55N - 2) • Protectionclass:IP 65/IP 67 • 3 design options: LU - 55N - 10 - measurementrangeup to 10m LU - 55N - 6 - measurementrangeup to 6m LU - 55N - 2 - measurementrangeup to 2m • Display unit is possible to connect to LEVELIS LU - 55

  21. Calibration test rigs of flow meters of ELIS PLZEŇ a.s. • Smaller dimensions DN 15 to DN 40 Twoof test rigs for calibration and measurement of flow meters DN 15 to DN 40 (1/2" to 1 ½") Main standard – weight, second standards – 3 pcs of induction flow meters Measurement method – flying start, steadystart Flow rate 6 l/hour to 12 m3/hour • Larger dimensions DN 25 to DN 150 Twoof test rigs for calibration and measurement of flow meters DN 25 to DN 100 or DN 150 (1" to 4" or 6") Main standards – 2 pcs of weights, second standards – 3 pcs of induction flow meters Measurement method – flying start, steady start Flow rate 0.15 m3/hour to 150 m3/hour

  22. Contact of ELIS PLZEŇ a. s. ELIS PLZEŇ a. s. Luční 15, P. O. BOX 126 304 26 Plzeň Czech Republic • Phone.: +420-377 517 711 • Fax: +420-377 517 722 • e-mail: sales@elis.cz • http://www.elis.cz • ask for special offer dedicated to your facility • ask for your nearest consultation company visit

More Related