1 / 28

Power Electronics and 42 V Automotive Power

Power Electronics and 42 V Automotive Power. US-Jordan Workshop, December 2002. P. T. Krein Grainger Center for Electric Machinery and Electromechanics Department of Electrical and Computer Engineering University of Illinois at Urbana-Champaign. Outline.

rodney
Download Presentation

Power Electronics and 42 V Automotive Power

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Power Electronics and 42 V Automotive Power US-Jordan Workshop, December 2002 P. T. Krein Grainger Center for Electric Machinery and Electromechanics Department of Electrical and Computer Engineering University of Illinois at Urbana-Champaign

  2. Outline • The growth of automotive power electronics. • Why 42 V? Power levels, accessories, safety, and other reasons. • Single and two-battery architectures. • Multiplexed power. • Major applications: power steering, starter-alternators, etc. • “Mild hybrid” designs based on 42 V. • Conclusion.

  3. The Growth of Auto Power Electronics • Power electronics for transportation is a major growth area. • Management of 12 V power • Audio systems • Motor controls • The move to higher voltages extends the reach in many ways. • The ultimate application is electric traction (but it is not really the most important!).

  4. Why 42 V? • When electricity is used to power various components (steering, brakes, suspension, air conditioning), the results are better efficiency and more flexible performance. • Many estimates have been made, such as 10% fuel economy improvements just be using a higher voltage.

  5. Why 42 V? • Possible new features: • Combined starter-alternator to reduce costs and enhance performance. • Regenerative braking. • “Start on demand” arrangements to avoid idle engines. • Improved, more efficient power steering and other subsystems. • Active suspensions. • Electrical valves and engine elements.

  6. Why 42 V? • The conventional car is rapidly becoming more electric. • A new car can contain up to 100 motors. • The total electric load is about 1000 W today, and is increasing toward 5000 W. • Conventional alternators cannot deliver more than about 2000 W, and are not efficient. • A higher voltage system supports lower current and loss.

  7. Why 42 V? Car motor usage is growing fast. It will soon rise to 200 electric motors per car. Source: Johnson Electric, 1999.

  8. Why 42 V? • Three alternatives: • Stick with 12 V. This limits effective power levels. • Get the voltage as high as possible (>100 V). This requires a major overhaul of safety systems and basic designs. • Push the voltage as high as possible before significant safety issues come into play. • 42 V tries to do the last: get the voltage as high as possible while avoiding severe safety issues.

  9. Safety Issues • A car’s electrical system is typically “open.” • Complicated wiring harnesses with close contact and hundreds of connections. • Regulatory agencies have set a level of about 60 V dc as the maximum reasonable level in an “open” system. • Headroom is required to stay below this level under all allowed conditions.

  10. Safety Issues • When there is no special electrical regulation, 36 V batteries are the maximum. • In a fully regulated system, 48 V batteries are possible within the 60 V limit. • The term “42 V” refers to a range of choices with nominal battery levels in the range of36 V to 48 V. • For comparison, we should take 42 V to mean a tripling of voltage, to give about triple the power.

  11. Safety Issues • We can also consider a “closed system,” in which electrical contact is more protected. • Closed systems are used in today’s hybrid and electric cars. • The voltage levels there can exceed 300 V dc.

  12. Power Levels • A car’s electrical system rivals that of a house.

  13. Architectures • Each automotive voltage level has advantages for some loads. • 12 V for lamps, sensors, electronics,controls. • 42 V for motors, pumps, and fans. • High voltage for electric tractionpower. • Incandescent lamps, for example, are more rugged and more reliable at low voltages.

  14. Architectures • Many possible architectures are possible. • Most retain some 12 V capacity. • They are typically divided into single-battery and dual-battery systems. • There is no consensus on which to select, and we are likely to see several.

  15. 42V BATTERY ENGINE 42V ALTERNATOR 42V LOADS DC–DC 12V LOADS Architectures • Single battery at 42 V: • Problem: jump starts? • Problem: charge balance. www.hoppecke.com

  16. 42V BATTERY ENGINE 42V ALTERNATOR 42V LOADS BIDIRECTIONAL DC–DC 12V BATTERY 12V LOADS Architectures • Dual battery: • The dc-dc converter mustbe bidirectional to supportstarting and reliability.

  17. REGULATOR ENGINE 42V STARTER/ ALTERNATOR 42V LOADS BIDIRECTIONAL DC–DC 12V BATTERY 12V LOADS Architectures • 12 V battery • Here a starter-alternatoris shown as well. Source: Mechanical Engineering Magazineonline, April 2002.

  18. 42V BATTERY ENGINE 42V STARTER/ ALTERNATOR 42V LOADS LOCAL DC/DC LOADS Architectures • Distributed converters with 42 V battery. • Here there are many dc-dcconverters at the variousloads.

  19. Architectures • The ultimate is a true multiplexed system: • Deliver a single 42 V power bus throughout the vehicle, with a network protocol overlaid on it. • Local dc-dc converters provide complete local operation and protection. • A ring bus or redundant bus structure could be used to enhance reliability. • Fuse coordination is important. • Most systems are partially multiplexed (power and network distribution rather than individual loads).

  20. Issues • “Key off” loads: sensors, alarms, clocks, remote systems. All draw down power. • “Flat” loads draw roughly fixed power, although the alternatoroutput can vary. • Connectors, 150 A  • Fusing. • Arcs: much above 12 V,it becomes possible tosustain an arc. Source: Amp, Inc.

  21. Major Applications • Electric power steering. • Two forms: assist pump and direct electric. • The assist pump uses an electric motor to drive a conventional hydraulic unit. • The direct systemuses electric motors withthe steering rack. • In both cases, action canbe controlled independentof the engine. Source: Delphi Corp., Saginaw Steering Systems Div.

  22. Major Applications • Electric air conditioningor heat pumps. • Remove the air conditioningsystem from engine belt drive. • Provides much better controland flexibility. • Easier cycling,possibleheat pump application.

  23. Major Applications • Integrated starter-alternator (ISA). • Build an electric machine intoor around the flywheel. • Provides on-demand starts. • Supports regenerative braking. • One prototype was even usedto cancel engine torquepulsations with active motorcontrol. Source: Mechanical EngineeringMagazine online, April 2002.

  24. Major Applications • Electromechanical engine controls. • Valves. • Fuel. Source: FEV Engine Technology, Inc.

  25. Mild Hybrids • A “light” hybrid or “mild” hybrid uses a small motor to manageperformance. • The engine can beshut down at stops. • Braking energycan be recovered. • The car does not operate in an“all-electric” regime. • The Honda Insight is a good example. Source: www.familycar.com

  26. Mild Hybrids • For a mild hybrid approach, about 5 kW or so is the minimum “traction” power. • The technique is accessible in a 42 V system, although higher voltage (144 V in the Insight) is beneficial. • One hesitation for 42 V is the marginal ability to support traction power and hybrid designs. • A 42 V ISA has substantial promise for fuel economy improvements.

  27. Key Power Electronics Needs • Low-cost dc-dc converters. • High-power bidirectional dc-dc converters. • Low-cost 42 V inverters for small ac drives. • Small ac motor designs, 100 W and below. • “Semiconductor fuse” automatic protection circuits. • Improved battery and system management. • High momentary power drivers for engine electromechanics.

  28. Conclusion • The continuing increase in electric power levels in automobiles will require higher voltages. • 42 V systems (batteries at 36 V or 48 V) are the highest possible in an “open” electrical system. • There are fuel economy improvements just at this level, but the extension to “mild hybrids” offers much more. • While the industry is now is a “go slow” mode for 42 V, no one doubts its eventual use.

More Related