An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Power² & Light² Version

  2. A complete unit with maximum power

  3. Objectives: • Pre-implant surgery, implantology, • maxillofacial surgeries and • conventional treatments • I-Surge micro-motor • Piezotome 2 LED handpiece • Newtron LED handpiece • Ultrasonic connector: • The Piezotome or Newtron handpieces are automatically recognized by the unit

  4. The Implant Center 2 combines the best of ultrasonic and motor technologies for: - Pre-implant surgery, - Implant surgery, - Implant maintenance, - Oral maxillofacial surgeries

  5. Technology • Motor technology: • Brushless • Rotation speed: • 100 – 40 000 rpm • 6 N.cm up to 24 000 rpm • Contra-angle ratio: 20:1 • Rotation speed at instrument end: • [5 – 2 000 rpm] Ultrasonic technology: Automatic frequency : 28-36 kHz Controlled amplitude Real-time power adjustment

  6. Ultrasonics Piezotome mode: modulated piezo signal (modulation) Newtron mode: piezo sinusoïdal signal

  7. Ultrasonic high power generator • Safety: preservation of soft tissue (nerves, membranes, • arteries). • Rapidity: fine, fast, precise and effortless • selective cut thanks to ultra-sharp, robust and • resistant Piezotome tips. • Comfort: Atraumatic treatments (no bone loss, no bleeding), fast healing, and greatly reduced post-operative pain.

  8. New touch-sensitive screen

  9. Giant 5.7’’ screen, • Touch-sensitive screen • (even with gloves), • Highlighting of the • activated function for • improved visibility.

  10. Screen zones Technology zone Piezotome mode activated Irrigation zone Power value zone Mode zone Options zone

  11. Piezotome mode

  12. Handpiece Respect of soft tissue, fast healing and greatly reduced post-operative pain Piloted by

  13. Boosted (up to 60 Woutput power) for a much quicker procedure, • It is up to three timesmore powerful than Piezotome/Implant Center 1 • Equipped with the latest high luminosity generation LEDs, • Highly resistant, • Does not induce overheating or extraneous vibration, • Can be sterilized, • Easy to clean (the nozzle can be detached).

  14. Piezotome mode: Clinical aspects • To perform successful, fast and worry-free delicate • pre-implant surgical procedures: • - fine osteotomy, • - osteoplasty, • - bone grafting, • - sinus lift, • - extraction, • - crown lengthening • - …

  15. Piezotome mode LED Purge Irrigation flow rate Progressive footswitch Irrigation activation/ deactivation Save Mode Fine power adjustment Power settings referring to bone density classification

  16. Piezotome 2 Tips • The tips dedicated to Piezotome 2 and Implant Center 2 are easily recognizable by: • their large base, • their “II” laser mark. Piezotome tips version 2 Piezotome tips version 1

  17. Piezotome 2 Tips • Stainless-steel medical grade • alloy with specific thermic and • surface treatments, polishing, etc. • Synthetic diamond coating with • special processing. • Clean, fast and effortless cut. • Ultra-sharp, robust and resistant tips. NEW PACK design!

  18. I-SURGE mode

  19. I-SURGE mode Handpiece motor (contra-angle, straight, multiplier) Progressive or ON/OFF footswitch Rotation speed Torque Save mode Rotation direction  Audible signal Forward/reverse drive selected through the footswitch 4 modes with complete customization possible

  20. Fast and simple settings adjustments: Modes 1. Select your program.

  21. I-SURGE: four pre-set modes Marking implant site 1200 Rpm 80 N.Cm 80 ml/min Pilot drill 800 Rpm 80 N.cm 100 ml/min Site preparation Tapping 15 Rpm 40 N.cm 100 ml/min Screwing 30 Rpm 40 N.cm 0 ml/min P1, P2, P3: Direct access to Rpm P4: Direct access to Ncm

  22. Fast and simple settings adjustments: CA 1. Select your program. 2. Select/change your contra-angle ratio.

  23. CA ratio selection Standard Multiplier Handpiece/ contra-angle Presentation of the most common contra-angle ratios (multiplier, direct, divider). 20:1 Direct Handpiece/ contra-angle If the ratio is not pre-defined, insert your own ratio by pressing this button. Standard Divider Handpiece/ contra-angle

  24. CA ratio selection 20:1 Set your own contra-angle ratio, whether it is multiplier, direct, or divider. Handpiece Setting

  25. Fast and simple settings adjustments: Rpm • 1. Select your program. • 2. Select/change your contra-angle ratio. • 3. Select the speed rotation needed by: • Pressing the + and – buttons on P1, P2 and P3 only, • Pressing the Rpm button.

  26. Fast and simple settings adjustments: Rpm 20:1 1235 Rpm setting

  27. Fast and simple settings adjustments: Ncm • 1. Select your program. • 2. Select/change your contra-angle ratio. • 3. Select the speed rotation needed by: • Pressing the + and – buttons on P1, P2 and P3 only, • Pressing the Rpm button. • 4. Select the torque needed by: • Pressing the + and – buttons on P4 mode only, • Pressing the Ncm button.

  28. I-SURGE mode 20:1 1235 Torque Setting 85

  29. I-SURGE mode • 1. Select your program. • 2. Select/change your contra-angle ratio. • 3. Select the speed rotation needed by: • Pressing the + and – buttons on P1, P2 and P3 only, • Pressing the Rpm button. • 4. Select the torque needed by: • Pressing the + and – buttons on P4 mode only, • Pressing the Ncm button. • 5. Increase/decrease/delete irrigation flow rate. • 6. Select the progressive or ON/OFF footswitch • 7. Save

  30. NEWTRON mode

  31. LED NEWTRON handpiece • Excellent visibility even in posterior areas, • Cold light (6 000 – 7 000°K) for better tissue recognition, • Ideal for working with loupes, • Powerful (100 000 Lux), very long-lasting LEDs, • Handpiece can be autoclaved at 134°C.

  32. NEWTRON mode: Clinical aspects • Periodontal procedures (surgical, non-surgical) • Endodontics • Microsurgery (apicoectomies) • Implant maintenance • etc,…

  33. NEWTRON MODEDelicate precision treatments Periodontics Maintenance Endodontics Prophylaxis - Scaling PH2R tip ET25 tip N°1S tip H3 tip Surgical endodontics Conservative and restorative dentistry Excavation Prosthetic finishing S12-90ND tip EX1 tip PM1 tip

  34. NEWTRON mode: Four power settings Low power; low amplitude. Delicate treatments: Periodontics. Medium power; medium amplitude. Precision treatments: Endodontics. High power; high amplitude. Routine prophylaxis: Scaling. Very high power; maximum amplitude. Special treatments: Crown loosening.

  35. NEWTRON mode: Fine adjustment • Each mode (Soft – Medium - High – Boost) enables fine power adjustment from 1 to 10.

  36. Ergonomics

  37. Peristaltic pumps • Silent-running pumps. • Extremely precise irrigation flow. • No bone necrosis. • Easy to install irrigation line.

  38. PiezoTouch™ footswitch Removable arch Irrigation Choice of instrument Programs Purge, Rotation direction PiezoTouch™ Progressive power regulation: Ultrasonics and motor

  39. PiezoTouch™ D1 to D3, the ultrasonic power delivered will vary between D3 – (01) and the power selected by the user (mode and fine adjustment). In D4 the ultrasonic power will only vary from 1 to 5 depending on the fine adjustment selected by the user. In Newtron function, the ultrasonic power in progressive varies between 1 and 10 in each mode.

  40. Optimal disinfection and asepsis Designed for use under the most demanding clinical conditions. All accessories (cords, handpieces, motor, tips…) can be autoclaved at 134°C for 18 minutes.