1 / 43

Dover Downs Hotel and Conference Center Dover, Delaware

Dover Downs Hotel and Conference Center Dover, Delaware. Brian Franco Lighting / Electrical Faculty Consultants: Dr. Mistrick and Dr. Moeck. Location. off of route one on highway thirteen. Dover, Delaware. hotel and conference center. Background Information.

rchandler
Download Presentation

Dover Downs Hotel and Conference Center Dover, Delaware

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Dover Downs Hotel and Conference Center Dover, Delaware Brian Franco Lighting / Electrical Faculty Consultants: Dr. Mistrick and Dr. Moeck

  2. Location off of route one on highway thirteen Dover, Delaware hotel and conference center

  3. Background Information • 1966 -1995: Horse Racing and NASCAR track • 1995 - 2001: $70,000,000 addition of casino, performance hall, hotel and several offices and meeting spaces • Currently: 2,500 slot machines, 234 hotel rooms, 18,000ft2 performance hall, 25,000ft2 of meeting space, 140,000 capacity grandstands

  4. Topics NOT Covered • Electrical Depth • hotel tower power system analysis • buffet kitchen power system redesign • Acoustic Breadth • acoustical analysis of the performance hall • LEED Rating Analysis Breadth • rating of existing building and redesign to earn more points

  5. Presentation Outline Lighting Redesign • Building Façade and Porte Cochere • Main Lobby • Lobby Bar and Lounge • Rollins Center Performance Hall

  6. Concept • Primary Functions: • Entertainment for the wealthy • Host business events • Atmosphere: • Inviting • Comfortable • Opulent • Elegant

  7. Presentation Outline Lighting Redesign • Building Façade and Porte Cochere • Main Lobby • Lobby Bar and Lounge • Rollins Center Performance Hall

  8. Building Façade and Porte Cochere • Main entrance to casino, main lobby, and performance hall • Beacon to the surrounding area • Makes first impression on guests

  9. Building Façade and Porte Cochere Lighting Goals • 1. Reinforce Dover Downs as a beacon to the surrounding area • Attract attention and make an excellent first impression • 3. Guide visitors from the parking lot to the porte cochere • 4. Highlight the main entry and other entries

  10. Building Façade • Hotel Tower • Flood light the hotel tower facade: 70W and 150W Metal Halide floods 150 W 70 W Typical Arrangement

  11. Building Façade • Dover Downs Sign and Roof Gazebo • LED (Light Emitting Diodes) lamps in sign (6 W each) • Recessed 39W T4 Metal Halide up-lighting around roof gazebo

  12. Building Façade • Façade: 4 – 5 fc vertical illuminance • Sign: 8 – 9 fc vertical illuminance • Gazebo: 4 – 6 fc vertical illuminance and 13 – 15 fc on upper ring

  13. Building Façade

  14. Porte Cochere • Trees, Fountain, and Balustrade • 39W T4 Metal Halide Uplights on trees for dramatic appearance • Recessed fountain lighting to cast “shimmering” light on arches • Uplighting on roof to highlight the balustrade

  15. Porte Cochere • Underneath the Porte Cochere • Highlight columns with T6 70W Metal Halide directional downlights • General lighting with 70W T6 Ceramic Metal Halide downlights

  16. Porte Cochere • Underneath the Porte Cochere • LED system in ceiling cove • 39W T6 Ceramic Metal Halide wall mounted fixtures in skylights

  17. Porte Cochere • Main Entrance: 16 – 20 fc vertical illuminance • Other Entrances: 13 – 16 fc vertical illumiance • Walls: 8 – 10 fc vertical illumiance

  18. Porte Cochere

  19. Building Façade and Porte Cochere • Controls and Power Density • ASHRAE 90.1 Standards: • Building Facades: 0.2 W/ft2 • Canopies and Overhangs: 1.25 W/ft2 • Signage is exempt • Dover Downs: • Building Façade: 0.2 W/ft2 *** exactly met • Porte Cochere: 0.61 W/ft2*** well under • Signage is exempt • Controls: • ASHRAE 90.1 requires automatic shutoff of exterior lighting • Photocell on 2nd story roof

  20. Presentation Outline Lighting Redesign • Building Façade and Porte Cochere • Main Lobby • Lobby Bar and Lounge • Rollins Center Performance Hall

  21. Main Lobby • Hotel registration and major circulation space • Welcoming point for guests of Dover Downs • Meeting spot for guests • Junction point for several adjacent spaces Registration Desk Casino Entrance Decoractive Gazebo and Columns Entrance from Porte Cochere Clerestory

  22. Main Lobby Lighting Goals • 1. Provide rich, warm atmosphere full of sparkle • Create an excellent first impression • 3. Avoid glaring reflections and direct glare from clerestory windows • 4. Keep energy use low

  23. Main Lobby • General lighting with 39W T6 Ceramic Metal Halide flood and spot beam downlights • Highlight columns with 39W T4 Ceramic Metal Halide directional downlights

  24. Main Lobby

  25. Main Lobby • Highlight decorative gazebo with 75W PAR30 Halogen uplights

  26. Main Lobby Direct Glare from Clerestory Windows Using this glazing the visible sunlight will be reduced by approximately 40%.

  27. Main Lobby Not shown: wall sconces and chandelier (provided by owner) Sconce Chandelier

  28. Main Lobby • Power Density • ASHRAE 90.1 Standards: • Space by Space Method: • Hotel Lobby: 1.3 W/ft2 • Decorative lighting is exempt • Dover Downs Lobby: • general lighting: 0.93 W/ft2 *** well under • sconces, chandelier, and table lamps are exempt

  29. Presentation Outline Lighting Redesign • Building Façade and Porte Cochere • Main Lobby • Lobby Bar and Lounge • Rollins Center Performance Hall

  30. Lobby Bar and Lounge • Directly connected to the main lobby • A place for guests to come and relax with friends and/or business associates • A warm and inviting space

  31. Bar and Lounge Lighting Goals • 1. Make the bar a focal point of the space • Attract attention with creative design • 3. Showcase art work • 4. Provide flexibility with control of lighting

  32. Bar and Lounge • 50W T4 Low Voltage Halogen for general lighting • 75W T4 Low Voltage Halogen to highlight artwork, wood burning stove, and to provide higher light levels behind bar

  33. Bar and Lounge

  34. Bar and Lounge

  35. Bar and Lounge • LED lamps in custom tables (6 W each); spaced for even illumination • Color changing custom table

  36. Bar and Lounge

  37. Bar and Lounge • LED lamps to wash acrylic wall behind bar (25 W) • Color changing bar background

  38. Bar and Lounge

  39. Bar and Lounge • Power Density • ASHRAE 90.1 Standards: • Space by Space Method: • Bar/Lounge: 1.4 W/ft2 • Decorative lighting is exempt • Dover Downs Bar and Lounge: • general lighting: 1.0 W/ft2 ***well under • custom tables are exempt

  40. Performance Hall

  41. Summary • Exterior • Beacon to the surrounding area, guiding visitors to the main entry • Main Lobby • Creates an excellent first impression on all guests of Dover Downs • Bar and Lounge • Provides a warm, inviting atmosphere with a unique design

  42. Acknowledgements • Professionals • Rich Wurtz from Dover Downs • The Lighting Practice • Faculty • Dr. Mistrick • Dr. Moeck • Professor Parfitt • Jonathan Dougherty • Friends and Family

  43. Questions?

More Related