Abstract

Abstract

Download Presentation

Abstract

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Abstract [Background] Orientation of acetabulum and wearing parameters are important prognostic factors after total hip arthroplasty. Various methods are proposed to measure them. All these methods need a standardized radiograph to verify their accuracy. In the past, mechanical devices are used. The disadvantages are expensiveness and operation error. We developed a program to do the same job. With this program, every parameter can be manipulated, and the results are reproducible without operation error. [Methods] With Windows plateform and Borland C++ builder tool, we developed the simulator. Ray tracing method is used to estimate the thickness of metal which the X-ray bean passed through. Then the photo-density is calculated by interpolation of look up tables. Parameters that we can manipulate include thickness, cup size, head size, inclination, anatomic anteversion, radiographic anteversion, and operative anteversion. [Results] With this program, we simulated 45 X-rays with different inclinations and anteversions. These simulated radiographs are printed in papers as teaching materials for practicing measurement of anteversions and wearings. The quality is as good as real X-rays, in which the real orientations and wearing are hard to estimate. We also use these simulated X-rays as source of automatic wearing measurement program. The result shows that the errors are within one millimeter. [Conclusions] Mechanical simulation is straightforward but expensive, with inevitable operation error. Computer simulated radiograph could be a standard to estimate accuracy of a new method and also serving as a training material for residents. Introduction Many parameters can (should) be measured. a. Orientations: Anteversion: Lewinnek method Liaw method Widmer method Fabeck method Inclination b. Wearing: Upper, Medial, Posterior Manual method Livermore method … Computerized method Hardinge method Shaver method Liaw method Verification of these methods is important!! Mechanical Simulation SIC03-P012 Simulated Radiograph of Total Hip Arthroplasty for Verifying Measuring InstrumentChen-Kun Liaw1,3 Rong-Sen Yang2 Sheng-Mou Hou2 Chiou-Shann Fuh3 Tai-Yin Wu4En Chu Kong Hospital, Taipei Hsian, Taiwan1National Taiwan University Hospital, Taipei, Taiwan2 National Taiwan University, Computer Science and Information Engineering3Taipei City Hospital4 • Advantages: • Easy to persuade people to use. • Disadvantages • Expensive • Precision? • Digitalization Our Solution • Building our own software • Cost down • Digitalization • Bias elimination • Batch processing can automatically produce many simulated X-rays. • Our Algorithm • Ray tracing • See X-ray as many X-ray lines • Trace every X-ray line • Calculate the total thickness of metal it passes. • Convert thickness to gray-scale pixel

More Related