Current Research. Experimental and numerical modeling of flow in a levee breach Experiments and simulation of sandbag motion at a levee breach Measurement and simulation of dam break flows Experimental study of erosion due to levee overtopping.
An Image/Link below is provided (as is) to download presentation
Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.Content is provided to you AS IS for your information and personal use only.Download presentation by click this link.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.During download, if you can't get a presentation, the file might be deleted by the publisher.
E N D
More Related Content
Presentation Transcript
Current Research Experimental and numerical modeling of flow in a levee breach Experiments and simulation of sandbag motion at a levee breach Measurement and simulation of dam break flows Experimental study of erosion due to levee overtopping
Objectives • To obtain detailed 3-D flow field from measurements in a model levee breach • To measure flow field around submerged structures • To simulate complex 3-D flow field in a levee breach and a flooded urban area using the VOF model
Breach Dimensions 200 ft N W E S 45 ft 465 ft Source: IPET Report 2, https://ipet.wes.army.mil
Physical Model • Scale 1:50 (model: real-life system/prototype)
ADV Velocity measured using 16 MHZ SonTekMicroADV Sampling rate (HZ) …………………..……. 0.1 to 50 Sampling Volume (CC) ………………..…. 0.09 Dist. To sampling volume (cm) ……….. 5 Resolution (cm/s) ….………………………. 0.01 Prog. Velocity range (cm/s) ………..….. 3, 10, 30, 100, 250 Accuracy ………………………………………… 1% of measured velocity, 0.25 cm/s Maximum depth (m) ………………………. 60 Source: http://www.sontek.com/download/brochure/adv.pdf
UVP An Ultrasonic Velocity Profiler (UVP) transducer transmits a short emission of ultrasound, which travels along the measurement axis. When the ultrasonic pulse hits a small particle in the liquid, part of it scatters on the particle and echoes back. Figure 1: This diagram explains the process of data collection by the UVP. The UVP is placed at an angle and reflection of the particles and from the bottom creates a velocity profile.
Mathematical Model • General • Ansys Fluent 6.3.26 used for modeling of levee breach flows • Solver: Pressure based • Multiphase model: VOF (Implicit scheme) • Turbulence model: k-epsilon • Grid specification • Boundary layer : meshed at the bottom of the channel • Grid: hexahedral with size = 2 cm
Ongoing and Future Research Flow measurements around model buildings using UVP Comparison of computed and measured velocity distributions Characterization of turbulence over irregular topography Inclusion of erosion and deposition of channel bottom and sides
Objectives • Developing a visual technique for tracking the motion of the sand bags and plotting their trajectories. • Determining the three-dimensional velocity components of the sand bags. • Formulating relationships between the sand bag size and shape and flow parameters. • Determining optimum sand bag size, and more efficient procedures for levee closure.
Ongoing and Future Research Understanding the general mechanics of sand bag motion. Formulating relationships between the sand bag size and shape and flow parameters. Determining the optimum size of sand bags and procedures for levee breach closure.
Objectives • To measure the instantaneous velocity over time for a dam break experiment. using an Ultrasonic Velocity Profiler (UVP) • To conduct LES simulation of a dam break wave. • To compare the measured and simulated flow field Figure: Experimental dam break set up. Notice the left hand side of the dam is filled with water up to 25 cm.
Experimental Set up • Flume: 7.67 m long, 25 cm deep, 18 cm wide, and 3.5% slope. • UVP placed at 45 deg. (schematics shown below). • UVP start measuring velocity as dam is lifted Experiment 1 Experiment 2 UVP Probe UVP Probe UVP probe facing upward to determine water level over time UVP probe facing downward to find the velocity profile at the bottom of a dam break wave
Numerical Set-up Volume: WATER Volume: AIR The grid used in the numerical simulation. The blue grid indicates the water and the other portion is the air at the initial location. A numerical grid with two separate volumes (water and air) was generated using Gambit, a grid generating program. The numerical simulation was conducted using FLUENT. Large Eddy Simulation (LES) and Volume of fluid (VOF) models were used.
Experimental Results T=1.0s This graph shows the velocity profile measured using a UVP. The two lines represent two separate trials of the experiment. The UVP continuously measures the velocity over time and generates a velocity profile at a specified time step. Multiple trials were conducted to compare the repeatability of the experiment.
Comparison A comparison between the numerical simulation and the experiment velocity profile on the upstream side of the dam break
Ongoing and Future Research Additional measurements throughout the model Experimental measurements of flow field including erosion and deposition following dam failure. Simulation of flow field following dam failure including erosion and deposition of bottom material
Objectives To understand and identify the parameters that govern the erosion and headcut formation during the overtopping of a levee. To conduct laboratory experiments overtopping small-scale dikes in a flume. To collect and evaluate the data and improve/modify breach models.