maxum edition ii gc the dream came true n.
Download
Skip this Video
Loading SlideShow in 5 Seconds..
Maxum Edition II GC , The Dream Came True! PowerPoint Presentation
Download Presentation
Maxum Edition II GC , The Dream Came True!

Loading in 2 Seconds...

play fullscreen
1 / 20

Maxum Edition II GC , The Dream Came True! - PowerPoint PPT Presentation


  • 177 Views
  • Uploaded on

Maxum Edition II GC , The Dream Came True!. The Synergy Of Two Powers. Siemens - the chromatograph leader in the German chemicals industry with 60% market share and 40 years experience.

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about 'Maxum Edition II GC , The Dream Came True!' - noelle-williamson


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
the synergy of two powers
The Synergy Of Two Powers
  • Siemens - the chromatograph leader in the German chemicals industry with 60% market share and 40 years experience.
  • Applied Automation - the global chromatograph leader in hydrocarbon processing measurement with 30-35% market share and 40 years experience too
  • THE RESULT: The most powerful and most versatile process gas chromatograph ever! Siemens becomes the largest global GC supplier with 80 years of combined experience

Maxum edition II

maxum edition ii the complete solution to all gc requirements
Maxum Edition II - The Complete Solution to All GC Requirements!
  • Siemens Applied Automation
    • The One Stop Shop for GCs
  • Customer’s Savings
    • Reduced investment through optimised, versatile and reliable GC solutions
    • Reduced engineering through one common platfrom
    • Reduced procurement time and project management
    • Short & smooth of start-up through consistent engineering
    • Less maintenance and minimum training
    • Reduced inventory through common spare parts
the maxum edition ii the technological breakthrough
The Maxum edition II - The Technological BreakThrough!
  • Ovens
  • Detectors
  • Valves and Application Tools
  • Electronics
  • Software
  • Inputs, Outputs and Reports
  • Human Interface and Workstation
  • Networking

Power andVersatilityin Every Aspects!

the most versatile analytical oven that meets all gc application requirements
The Most Versatile Analytical Oven that Meets All GC Application Requirements

Air Bath (1 or 2 temp sections/zones)

Airless (1 or 2 ovens)

why the 2 oven type 4 configuration choice
Airless (Space Heater)

One or two Independent oven with separate doors. Independent maintenance

Space heater does not need instru air. Especially suitable for remote locations. Save upto 500 Euro per GC each year on power & air utilities

Higher maximum operating temperature beyond 200 deg C and effective thermal efficiency. Oven can also be used for high temp sampling system

Air bath (Air Bath Heater)

Upto two separate temp section/zone through thermal isolation in one large compartment

Air bath heater provides fast warm up and stabilization time. Permits programmed temperature or sub-ambient operation with vortex cooling configuration

Large, spacious compartment for complex applications and easy maintenance

Why the 2 Oven Type, 4 Configuration Choice

Programmed Temperature

Single Airless

Dual Airless

Single Air Bath

Split Air Bath

the widest choice and largest quantity of detectors per gc
The Widest Choice and Largest Quantity of Detectors per GC
  • A total of 7 different technologies in detector modules
    • 4- and 8-cell Thermal Conductivity with thermistors (max 24 TCDs for % measurement)
    • 2-cell Thermal Conductivity with filaments
    • Flame Ionization or Flame Ionization with Filament TCD (Max 3 FIDs for ppm HC measurement and 6TCDs for % measurement)
    • Flame Photometric (Max 3 FPDs for low sulphur measurement)
    • Electron Capture
    • Helium Ionization
    • Electrolytic Conductivity
  • Each Maxum Ed II can effectively replace the job of upto 5 traditional GCs without operation compromise. The cost saving in GC shelters and accessories is upto 70% of total analyzer system cost!
the benefits of more detectors parallel chromatography

S

S

S

R

Detector Vents

Carrier In from EPC

2

1

3

Column 1

10

4

SSO

9

5

Column 2

8

6

7

Sample

Out

In

Fixed Restrictor

The Benefits of More Detectors - Parallel Chromatography
  • More detectors allow more applications per oven
    • Critical/control service can be measured in unprecedent fast cycle time
    • Critical/control service can also have redundant application including oven in one GC
    • Complex analyzer can be replaced by Maxum Ed II because of faster analysis time and more components measured eg Mass Spectrometer

Traditional SerialChromatography

Maxum ParallelChromatography

the benefits of more detectors inter column detectors the siemens standard feature
The Benefits of More Detectors – Inter-column Detectors, The Siemens Standard Feature!
  • Adequate detectors ensure that Inter-column detectors are always considered.
  • Traditionally, detectors take-up oven space, micro-processor power, and incur cost. Therefore, GC vendors do omit inter-column detectors to cut cost.
  • In a typical GC application, the first column provide coarse separation of the sample. Then the sample is switched to various columns for further specific fine separation. The switching is basically determined by time.
  • Inter-column detectors eliminate time consuming and tedious guess work when deciding oven flow path switching timing between columns. This happens whenever the columns aged or are replaced.
the benefits of more detectors power made simple
The Benefits of More Detectors - Power Made Simple
  • More detectors allow more applications per oven
    • Two or more streams can be analyzed in parallel instead of stream switching. Therefore all streams results are updated in each cycle of analysis.
  • There are enough detectors to standardised and simplify chromatography application methods
    • Applications are broken down into simple standardised sub-applications called Applets.
    • Applets reduces cost by reducing complexity in user understanding, training and maintenance.

Stream 1

Stream 2

Stream 3

industry leader in oven switching valve choice and reliability
Industry Leader in Oven Switching Valve Choice and Reliability
  • Extremely high reliability and long life diaphragm valves
    • 10-port Plunger-less diaphragm vapor sample valve
    • Proven MTBF 10 years.
    • 6-port Diaphragm-plunger high pressure vapor or liquid sample valve
    • Proven MTBF 6 years
  • Vaporising liquid injection valve
    • Precision sample size control and fast, clean injection
    • Ideally suited for liquid chemical analysis
  • Valveless, Live column switching
    • Essentially zero dead volume, precise sample size for fast column switching and sample injection with capillary columns
    • No parts to fail or wear out
the winner in electronics power processing speed
The Winner in Electronics Power & Processing Speed
  • Upto 4 32-bit 486 electronic processors with internal serial signal distribution
    • 1 x 486 32-bit Dedicated System Controller for communications, human interface and database management
    • Upto 3 x 486 32 bit Dedicated Sensor Controllers for detector data acquisition; independent controllers for each detector module.
    • Plug and Play technology
    • TCP/IP platform
carrier gas pressure control is a standard not an option
Carrier Gas Pressure Control is a Standard Not an Option!
  • Upto 8-channel Electronic Pressure Control
    • Absolute digital control of carrier gas pressures. No more tedious flow adjustment on site start-up and routine maintenance.
    • The GC oven always involves various carrier gas flow paths to different analysis columns. The source carrier gas pressure therefore varies because different columns have different length and separation time.
    • Traditionally, needle valves are used as restrictors to vary the source carrier gas pressure. These needle valves always creep during transportation and overtime requiring frequent tedious flow adjustment maintenance.
the only mmi that replaces the traditional chromatogram recorder in zone 1 div 1 areas
The Only MMI that Replaces the Traditional Chromatogram Recorder in Zone 1/Div 1 Areas
  • Unique feature allowing Zoom, Pan function on any area of a Chromatogram; Display detector signals value and retention time
  • Memory for 8 hour storage of Chromatograms in GC. Infinite memory storage with network PC workstation
the only process gc with ez chrom software
The Only Process GC with EZ Chrom Software!
  • Embedded Advance EZChrom brings laboratory capabilities to the process environment
  • Windows Based with tools bars, user friendly requiring minimum training to operate
  • Powerful real time distributed database integrates all analyzer functions into the underlying architecture
  • Flexible and extensible functionality available through user programming using MaxBasic programming language

The Maxum Ed II gives you a warning alarm when your columns starts degrading

a full range of signal i os from gc
A Full Range Of Signal I/Os from GC
  • Discrete Input and Output devices
    • Isolated Analogue outputs
    • Analogue inputs
    • Digital inputs and outputs
  • Local control of serial report printers
  • Local output of Modbus serial communication
  • In addition, all capabilities are extended by Networking
full workstation capability with pc
Full Workstation Capability with PC
  • System Manager
    • Complete network overview and monitoring with analyzer status
  • EZChrom
    • Full access to embedded analyzer EZChrom method
    • Convenient multi-window chromatogram displays
    • Easy method creation and editing
  • Numerous other maintenance tools
    • Backup, restore, update
    • Data Logger
    • APC 8.1 for compatibility with Optichrom Advance
  • Multiple workstations permitted on network; compatible with telephone or LAN connection for remote access
versatile and open networking just like your office pcs
Versatile and Open Networking, Just Like Your Office PCs!
  • All Maxum edition II GCs connect to a high speed network
    • Direct GC-to-GC communications; no PC, server or other “network controller” device required
  • Three communication options available to allow systems to be designed for lowest cost and highest performance
    • Ethernet
    • DataNET
    • Data Hiway
  • Full backwards connectivity to Optichrom Advance
versatile and open networking just like your office pcs1
Versatile and Open Networking, Just Like Your Office PCs!
maxum edition ii the optimised cost saving gc solution for the future
Maxum Edition II The Optimised & Cost Saving GC Solution for the Future!
  • Siemens Applied Automation
    • The One Stop Shop for GCs
  • Customer’s Savings
    • Reduced investment through optimised, versatile and reliable GC solutions
    • Reduced engineering through one common platfrom
    • Reduced procurement time and project management
    • Short & smooth of start-up through consistent engineering
    • Less maintenance and minimum training
    • Reduced inventory through common spare parts