1 / 10

Station Metadata The NRL (Nominal Response Library)

Station Metadata The NRL (Nominal Response Library). Dr. Mary Templeton IRIS Data Management Center Managing Data from Seismic Networks September 9-17 2015 Hanoi, Vietnam. What is the NRL?. Library of manufacturers ’ recommended nominal instrument responses SEED RESP files

Download Presentation

Station Metadata The NRL (Nominal Response Library)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Station MetadataThe NRL(Nominal Response Library) Dr. Mary Templeton IRIS Data Management Center Managing Data from Seismic Networks September 9-17 2015 Hanoi, Vietnam

  2. What is the NRL? • Library of manufacturers’ recommended nominal instrument responses • SEED RESP files • Help matching an instrument’s configuration with the correct response • Notes describing instrument and response differences

  3. What is the NRL? • Includes • 66 sensor models (14 manufacturers) • 48 datalogger models (11 manufacturers) • 11700 RESP files (97% are datalogger) • Constantly growing

  4. How is the NRL Constructed? • Response information from manufacturer • Instruction file links instrument configuration with pole/zero or FIR coefficient files • Generate RESP files from instruction file • Accuracy checking

  5. How Can You Use the NRL? • Web version (http://ds.iris.edu/NRL/) • Follow links for manufacturer and model • Notes are at the top • Table helps locate the correct RESP file • Example: STS-2 sensors (http://ds.iris.edu/NRL/sensors/streckeisen/streckeisen_sts2_sensors.htm)

  6. How Can You Use the NRL?

  7. How Can You Use the NRL? • Copy PDCC from a memory stick • In PDCC: • Select a channel • Launch “Select Instrumentation” • Download latest version of the Library (but not this week!) • PDCC checks the IRIS website for NRL changes • Answer questions to find the correct responses

  8. How Can You Use the NRL? • Update your Nominal Response if: • you have calibration info • your accelerometer full scale voltage and/or clip level differs • you have a passive sensor and • your resistors differ • you need to take sensor-amplifier impedance into account • You’ve set a software gain on your datalogger

  9. Two Things You Need To Know • If you change a stage gain, you must recalculate the final (stage 0) gain • The final (stage 0) normalization frequency must lie within the passband of the response curve: passband

  10. What Does the NRL Still Need? • Contact Mary Templeton • met@iris.washington.edu

More Related