nrc canadian codes centre n.
Download
Skip this Video
Loading SlideShow in 5 Seconds..
National Energy Code for Buildings 2011 – Lighting PowerPoint Presentation
Download Presentation
National Energy Code for Buildings 2011 – Lighting

Loading in 2 Seconds...

play fullscreen
1 / 27

National Energy Code for Buildings 2011 – Lighting - PowerPoint PPT Presentation


  • 90 Views
  • Uploaded on

NRC Canadian Codes Centre. National Energy Code for Buildings 2011 – Lighting. Cathy Taraschuk, Heather Knudsen, Elisabeth Girgis March 16, 2011. Outline. Scope Methods of compliance Exterior lighting – simple prescriptive Interior lighting – simple prescriptive building area method

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about 'National Energy Code for Buildings 2011 – Lighting' - nan


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
nrc canadian codes centre
NRC Canadian Codes Centre

National Energy Code for Buildings 2011 – Lighting

Cathy Taraschuk, Heather Knudsen, Elisabeth Girgis

March 16, 2011

outline
Outline
  • Scope
  • Methods of compliance
  • Exterior lighting – simple prescriptive
  • Interior lighting – simple prescriptive
      • building area method
      • space-by-space method
    • Interior lighting trade-off
    • Performance compliance
scope
Scope
  • Applies to lighting components and systems connected to building's electrical service
  • Exemptions:
      • emergency lighting automatically off during normal building operation
      • lighting in dwelling units
      • where impractical
  • Similar to ASHRAE 90.1 in content
methods of compliance
Methods of compliance
  • Simple prescriptive
  • Interior lighting trade-off
  • Performance compliance
outline1
Outline
  • Scope
  • Methods of compliance
  • Exterior lighting – simple prescriptive
  • Interior lighting – simple prescriptive
      • building area method
      • space-by-space method
    • Interior lighting trade-off
    • Performance compliance
exterior lighting options
Exterior lighting – options
  • Simple prescriptive or performance compliance only
  • For systems connected to building's electrical service
exterior lighting prescriptive compliance equations
Exterior lighting – prescriptive – compliance equations
  • Step 1: Total connected exterior lighting power for specific exterior applications ≤ specific exterior application allowance + base site allowance
  • Step 2: Total connected exterior lighting power for general exterior applications ≤ general exterior application allowance + unused base site allowance from Step 1
exterior lighting prescriptive controls
Exterior lighting – prescriptive – controls
  • Control types
      • dusk-to-dawn → astronomical time control or photosensor
      • other → astronomical time control, photosensor, photosensor & time switch, or equivalent
  • Exemptions
      • covered vehicle exterior entrances or exterior exits from buildings or parking structures where needed for safety, security or eye adaptation
outline2
Outline
  • Scope
  • Methods of compliance
  • Exterior lighting – simple prescriptive
  • Interior lighting – simple prescriptive
      • building area method
      • space-by-space method
    • Interior lighting trade-off
    • Performance compliance
interior lighting prescriptive compliance equation
Interior lighting – prescriptive – compliance equation
  • Installed interior lighting power cannot exceed interior lighting power allowance as determined by either
      • building area method, or
      • space-by-space method
  • Can't be mixed
interior lighting prescriptive installed interior lighting power
Interior lighting – prescriptive – installed interior lighting power
  • Includes
      • all power used by luminaires, both permanent and supplemental or task-related provided by movable or plug-in luminaires
      • higher wattage when more than one system provides lighting but not simultaneously
interior lighting prescriptive building area method
Interior lighting – prescriptive – building area method
  • Interior Lighting Power Allowance – building area method:
      • select building type or equivalent from table based on primary use
      • multiply lighting power density by gross lighted area to get interior lighting power allowance
      • if 10% or more of gross lighted area can be classified as another type, must use space-by-space method
      • if no equivalent, must use space-by-space method
interior lighting prescriptive space by space method
Interior lighting – prescriptive – space-by-space method
  • Interior Lighting Power Allowance – space-by-space method:
      • for each enclosed space
        • find lighting power density from table for use of space or equivalent
        • multiply lighting power density by gross interior floor area of space
      • sum results for all spaces
interior lighting prescriptive controls
Interior lighting – prescriptive – controls
  • Automatic shut off
      • time-of-day operation
      • occupant sensor
      • signals that area is unoccupied
  • Exemptions
      • 24-hour operation
      • patient care is rendered
      • safety or security issues
interior lighting prescriptive controls for spaces

classrooms and lecture halls, excluding shop and laboratory classrooms

conference, meeting and training rooms

employee lunch and break rooms

storage and supply rooms up to 100 m2

copying and printing rooms

dressing, locker and fitting rooms

offices up to 25 m2

washrooms

Interior lighting – prescriptive – controls for spaces
  • At least one control for general lighting in enclosed spaces
    • All listed below must be automatic  occupant sensor
interior lighting prescriptive automatic daylighting controls for toplighting
Interior lighting – prescriptive – automatic daylighting controls for toplighting
  • Daylight area > 400 m2 photocontrolto reduce general lighting
  • Exemptions
      • light blocked
      • insufficient skylight aperture
      • small enclosed space above 55⁰N latitude
  • Requirements on how to calculate daylighted area
interior lighting prescriptive automatic daylighting controls for sidelighting
Interior lighting – prescriptive – automatic daylighting controls for sidelighting
  • Sidelighted area > 100 m2 photocontrol to reduce general lighting
  • Exemptions
      • light blocked by adjacent building
      • insufficient sidelight aperture
      • retail spaces
  • Requirements on how to calculate sidelighted area
outline3
Outline
  • Scope
  • Methods of compliance
  • Exterior lighting – simple prescriptive
  • Interior lighting – simple prescriptive
      • building area method
      • space-by-space method
    • Interior lighting trade-off
    • Performance compliance
trade off
Trade-off
  • Applies to interior lighting only
  • Installed Interior Lighting Energy (IILE) ≤ Interior Lighting Energy Allowance (ILEA)
  • ILEA calculated in accordance with prescriptive space-by-space method
trade off1
Trade-off
  • More detailed calculation  series of equations to calculate ILEA and IILE
outline4
Outline
  • Scope
  • Methods of compliance
  • Exterior lighting – simple prescriptive
  • Interior lighting – simple prescriptive
      • building area method
      • space-by-space method
    • Interior lighting trade-off
    • Performance compliance
performance compliance limitations
Performance compliance limitations
  • NECB Part 4 Lighting  no limitations
questions

Questions?

www.nationalcodes.ca