250 likes | 405 Views
R&D at IMB-CNM for future accelerators. Manuel Lozano Giulio Pellegrini. IFCA. CNM Clean Room expansion. From 1000 to 1500 m2 New equipments ready with partial coverage for 15 cm (6’’) wafers We plan to do prototype runs of simple detectors in 6’’ in 2010. New ion implanter for 6’’. PhD
E N D
R&D at IMB-CNM for future accelerators Manuel Lozano Giulio Pellegrini
IFCA CNM Clean Room expansion • From 1000 to 1500 m2 • New equipments ready with partial coverage for 15 cm (6’’) wafers • We plan to do prototype runs of simple detectors in 6’’ in 2010 New ion implanter for 6’’
PhD Manuel Lozano Enric Cabruja Miguel Ullán Giulio Pellegrini Celeste Fleta David Quirion Marie Ruat Techniciens David Almansa Joaquín Rodríguez PhD students Sergio Díez Juan Pablo Balbuena Daniela Bassignana Consuelo Guardiola Incorporation of a CPAN Engineer and a CSIC Electronic Technician Increased technical capacity Better position to afford GICSERV projects. Radiation Detector Group
Collaboration with other Spanish Groups IFIC IFAE IFCA University Santiago de Compostela University Barcelona R&D in radiation detectors at CNM
IFIC • ALIBAVA detector readout system • ALIBAVA Telescope • Modules for ATLAS upgrade
System finished 20 units already distributed 20 more units manufactured Upgrade for test beam telescope Upgrade for ethernet connectivity ALIBAVA: A readout system for microstrip silicon sensors
Study of radiation hardness of 0.25 µm SiGe BiCMOS technologies from IHP (Germany) Study of radiation hardness of LDMOS transistors for DC-DC converters. Understanding radiation degradation mechanisms Simulation and modeling of irradiated devices (transistors, detectors, etc) Embedded fanins for Endcap modules Dummies Modules for ATLAS upgrade 1st IHPtest chip 1st IBMtest chip 2nd IHPtest chip
IFAE • Planar & 3D pixels for IBL and ATLAS upgrade • Bump bonding packaging
Planar & 3D pixels for IBL and ATLAS upgrade • CNM and IFAE are part of the ATLAS 3D Collaboration for the IBL (Insertable B-layer) of the ATLAS Pixel detector • Collaboration being formed. MoU to be signed soon. Ref.: O. Rohne – Vertex 2009
In collaboration with IFAE Bump bonding already working Medipix and ATLAS pixels successfully bonded Efficiency in bump-bond contact > 99.5% (aim for 99.99% or better) Now working to increase yield and qualify the technology SET/Süss FC150 machine 1 micron placing accuracy Optimized reflow 2010 FPA Project to continue with bump bonding in FE-I4 chips with planar and 3D detectors Bump Bonding
IFCA • IR transparent detectors • Thin strip detectors for CMS and ILC • 3D pixels for CMS
In collaboration with IFCA Run almost finished 12 different detectors Common parameters: active area= 1.2x1.5 cm2 circular window in the back metal 256 readout strips with 1.5 cm length IR transparent detectors GICSERV SiO2 thickness map (wafer 2) Strips with 3 µm Al width lines
Run already started Based on SOI wafers 100, 150 and 200 µm thick active devices Strip detectors with integrated fanins in double metal technology Grooves in silicon to integrate optical fibres to measure deformation GICSERV funded Thin devices GICSERV
University Santiago de Compostela • 3D pixels for LHCb • Thin pixels
In collaboration with Glasgow University First 3D Medipix-like sensor bump bonded to Timepix chip Successfully tested in CERN test beam Pion beam Individual pion tracks telescope DUT 3D pixels for LHCb GICSERV
Thin pixels for LHCb upgrade • First tests of bump bonding of thin pixel detectors with Timepix chip. • Detectors already manufactured at CNM • Waiting for thinning and bump bonding • GICSERV funded GICSERV
University of Barcelona • Device simulation of Geiger mode APDs with Sentaurus • AMS HV 0.35 µm CMOS technology. • Difficulty to get technology parameters • Some are deduced from technological kit, others are estimated indirectly.
Other technologies under development • 3D detectors • Double side strip detectors • Stripixels • Active edge and trenched detectors • Ultrathin 3D detector • Neutron detectors • Avalanche Photodiodes
3D detector technology • Second institute in the world (after Stanford) in developing a 3D detector technology • Success with Medipix type pixel sensors • Now we are designing of a new mask set for ATLAS pixel sensors • Work done in the framework of RD50 collaboration. Electron collecting strip detectors • Bias Voltage fixed at 150V for all irradiated samples • Non-irradiated sample biased at 18V • Detector’s ceramic based board temperature between -10°C to -15°C • Measured with ALIBAVA system (25ns shaping time) GICSERV Partially funded GICSERV
Double side strip detectors developed for Monash University (Australia) Also developing double side packaging and wire bonding Future collaboration with Universidad de Huelva for nuclear physics Double side strip detectors Stripixels • Combination of the concept of double side reading with 3D contacts • Better performace than classic stripixels • Single side processing • 2D position sensitivity • 2N readout channels (instead of N2) • Simulations and mask design ready • Wafers to be processed GICSERV
Trenches used to reduce the dead area at the edge of the sensor (also named edgeless, slim-edge, ...) Work started in collaboration with IFAE (Cristobal Padilla) Features: Implanted edge side Backplane and edge in the same electrode Designed detectors: PAD Microstrips MediPix2 Circular Active edge and trenched detectors
Thin membrane 300um Etched backside Ultrathin 3D detector • 10 µm thick detector • Virtually no entry window • Used for tracking of light particles GICSERV Neutron detectors Planar detector • Geant4 simulation • Detector design and manufacturing • Conversion layer deposition • Used for dosimetry Perforated detector
Avalanche Photodiodes (APDs) • Power Devices and Radiation Detectors Groups at IMB-CNM have started a new research line in optoelectronic silicon detectors. • Cover the needs of the scientific community with custom made devices designed for specific applications • We have finished electrical and technological simulations • We are now designing the masks • Next year we will process the devices. • We plan to develop • Linear mode APDs (to use with scintillators) • Geiger mode APDs high energy tracking • In the future, also SiPMs • We are open for collaboration and feedback from other groups Electric field in the avalanche zone
GICSERV • Easy access through the Spanish “Access to Large Facilities” Program: ICTS GICSERV • New call now open until 15 January 2010 • Average 70 applications, 50 accesses per call • Projects related to radiation detectors: • 2009: 7 projects approved (1 rejected) • 3D medipix-type detectors; Stripixels; Thin pixel detectors; Thin strip detectors; Atlas pixels with slim edge; UBM for DEPFET bump bonding • 2008: 5 projects approved • 2007: 3 projects approved • Big increase in radiation detector activity in CNM Clean Room • GICSERV Progam working very satisfactory
Announcement Next RD50 meeting will be held in Barcelona (31st May, 1st & 2nd June 2010) http://cern.ch/rd50/