1 / 5

LKr Readout with CARE modules

LKr Readout with CARE modules. CARE Features. Each CARE consists of 4 sectors → total 896 “virtual modules” in LKr. The analog LKr signals are digitized with 40 MHz. Raw data input is 8x120=960 MB/s per LKr sector (16 chans).

mikasi
Download Presentation

LKr Readout with CARE modules

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. LKr Readout with CARE modules NA62 TDAQ WG Meeting, Anacapri, 2 Sep 2009

  2. CARE Features • Each CARE consists of 4 sectors→ total 896 “virtual modules” in LKr. • The analog LKr signals are digitized with 40 MHz. • Raw data input is 8x120=960 MB/s per LKr sector (16 chans). • Each LKr sector (8x CPDAS = 16 chans) has two DDR2 SODIMM socketswith maximum 2 x 4 = 8 GB (intermediate) data storage. • This corresponds to ~8.3 s of continuous data-taking @ 40MHz. • Read-out is with 1 GbE link/sector = ~80 MB/s using jumbo frames(4 GbE links per CARE), which represents approx. 1 MHz event rate maximum (compared to 10 KHz for the CPD) if readout is sustained between spills. • The same physical format as the CPD in order to re-use the CPDTR trigger sum board, the 7000 CPDAS cards and the FASTBUS crates for power and cooling • CARE has no FASTBUS interface. • 80 MHz Clock as CPD, with SoB (Start of Burst) and EoB (End of Burst)and other functionalities (to be defined) by addition of a TTCrx device. • CAN-bus for the DCS (Detector Control System)which interfaces to an ELMB module on the CAREfor configuration & monitoring of the CARE module. NA62 TDAQ WG Meeting, Anacapri, 2 Sep 2009

  3. LKr Readout with CARE (1) • First attempt at defining an architecture • 224 CAREs = 896 LKr 16-chan sectors, continuous (untriggered) data-taking (960 MB/s per sector) in burst • Start-of-burst signal absolutely necessary to sync all CARE modules • A (bidirectional) GbE connection/sector (max 80 MB/s).. • ..connecting via GbE switches.. • ..to processor nodes that doevent building and processing(e.g. zero-suppression) andforward the events to NA62 DAQ In addition: • Analog trigger sums go tothe LKr L0 trigger sysstemusing the existing cabling • Several CAN buses (e.g. 8,i.e. 28 CAREs/bus) forconfiguration & monitoring NA62 TDAQ WG Meeting, Anacapri, 2 Sep 2009

  4. LKr Readout with CARE (2) Readout Controller • central role in LKr readoutsteered by inputs from Lx trigger(s) • issues broadcasts to CAREs, containing 40+ event requestsand the address of a singledestination eventbuilder/processor node port • event request = timestampof the event from the start-of-burst • each processor node hasmultiple GbE ports (e.g. 4) • each CARE assembles and sends the data of the 40+ events in one (jumbo) frame (ca. 9000 bytes) to the destination node port (jumbo in order to optimize use of GbE bandwidth) • note: Ethernet between RC+CARE+ switches+nodes and TCP/IP between nodes+TDAQ NA62 TDAQ WG Meeting, Anacapri, 2 Sep 2009

  5. LKr Readout with CARE (3) GbE Switches • CARE sector GbE output @ 80MB/s→ (80M/9000)*47 = ca. 400 kHz evtrate • event building: 896 jumbo frames(47 evts, ca. 8 MB) go to one output port(or to 4 ports of one node in parallel?) • at 80MB/s (max GbE) this takes 100 msnot incl. latency • one port then is able to consume470 evts/s • so to sustain 400 kHz event rateneed 400k/470 = ca. 850 GbE ports= ca. 200 processor nodes ifthere are 4 ports/node NA62 TDAQ WG Meeting, Anacapri, 2 Sep 2009