Fundamentals of Product Safety Design Berri Remenick NARTE Certified Product Safety Engineer Product Safety Manager Washington Laboratories, Ltd. September 14, 2007 Gaithersburg, MD. Outline. Background Insulation Component Selection Labeling Documentation Wiring Resistance to Fire.

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about 'Outline' - meli


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
slide1

Fundamentals of Product Safety DesignBerri RemenickNARTE Certified Product Safety EngineerProduct Safety ManagerWashington Laboratories, Ltd.September 14, 2007Gaithersburg, MD

outline
Outline
  • Background
  • Insulation
  • Component Selection
  • Labeling
  • Documentation
  • Wiring
  • Resistance to Fire
product safety requirements
Product Safety Requirements
  • US/Canada:

NRTL Listing (cULus, cTUVus, cCSAus)

  • Legal requirement, customer requirement, or to limit liability
  • Europe:

CE Mark

  • Legal requirement
  • Others:

CB Report

To facilitate International Approvals.

product safety hazards
Product Safety Hazards
  • Electric Shock Hazards: Accessible parts over 30Vrms, 42.4Pk, or 60VDC.
  • Energy Hazards: Energy level over 240VA or 8A
  • Fire Hazards: Materials, Enclosure, Abnormal conditions
  • Mechanical Hazards: Moving parts, Sharp edges, Tipping, Handles
  • Radiation Hazards: Lasers, UV, Sonic
  • Thermal Hazards: External temps, component temps
design requirements
Design Requirements

Protection against electric shock and energy hazards:

  • The OPERATORcan not touch bare or inadequately insulated parts at hazardous voltage or energy levels.
  • Hazardous Voltage Level is typically >30Vrms, 42.4Vpeak, or 60VDC.

Hazardous energy is typically >240VA or 8A

Protection may be provided via insulation, guarding or interlocking.

what is insulation
What is Insulation?
  • Physical barrier between two parts (tape, plastic shield, wire insulation, enclosure, etc)
  • Separation between two parts through air or along a surface (creepage or clearance distance)
insulation types
Insulation Types
  • Functional / Operational Insulation (DC input to ground)
  • Basic Insulation (Primary to Ground, TNV to Ground, TNV to SELV)
  • Reinforced Insulation (Primary to Secondary)
spacings creepage clearance
Spacings (Creepage / Clearance)
  • Based on the required insulation for your circuit.
  • Based on the maximum working voltage for your circuit.
  • Based on the environment the product will be used in (Pollution Degree)
  • Based on the PCB material: Material Group - Comparitive Tracking Index (CTI)
creepage clearance12
Creepage / Clearance

Creepage

  • Creepage = distance between two points along the surface
  • Creepage is measured on 1:1 artwork or on a blank board
  • Locations of circuits determined by reviewing schematics

Clearance

  • Clearance = distance between two points through the air
  • Clearance is measured on a populated sample
component selection
Component Selection
  • Safety Critical Components must have the appropriate approvals or additional evaluation will be required.
  • Safety Critical Components:
    • Devices in the AC path (inlets, fuses, switches, power supplies, transformers, etc.)
    • Motors, fans
    • Power conversion components (AC-DC or DC-DC Converters)
    • Any isolation component (Transformer, Bridging Capacitors, MOVs,)
    • Wiring
    • Batteries
    • Others depending on their application.
component selection14
Component Selection
  • For NRTL approvals, all components must be UL approved.
  • For CE Mark approvals, all components must have a European approval such as CE, TUV, VDE, etc. (exception: fuses and wiring can be UL approved)
  • For GS or CB Scheme approvals, all components must have a TUV, VDE, or other official European approval. CE Mark is not acceptable for these approvals.
  • Approval certificates required (TUV or VDE Cert, CE Declaration of Conformity, UL File number, etc.)
labeling and marking
Labeling and Marking
  • Rated voltage, current or power, frequency
  • Manufacturer’s name or registered trademark.
  • Model or type number.
  • Fuse replacement info (if applicable).
  • IEC symbols wherever possible.
  • Warnings and Cautions appropriate for the particular equipment.
user instructions
User Instructions
  • Installation Instructions - information regarding mounting, connection to the supply, ventilation, input ratings, etc.
  • All information regarding use, cleaning, maintenance (if necessary).
  • All safety warnings and cautions.
  • Rack Mount instructions.
  • Safety-related information to be in appropriate language of the country you are exporting to.
  • Some standards have entire sections of specific info that must be in manual.
wiring and connection to the supply protective earth
Wiring and connection to the supply – Protective Earth -
  • PE conductor must be green/yellow or bare insulation conductor
  • PE connections must be double secured so that both the wire and insulation are crimped
  • IEC PE symbol shall be marked adjacent to PE stud
  • PE conductor shall connect to chassis directly from input (inlet, terminal block, etc).
  • PE conductor must be secured with washer and locknut.
  • Additional PE conductors can be secured to PE stud with a second washer and locknut.
pe stud example
PE Stud Example

EMI FILTER

CHASSIS

TO OTHER

CONNECTION

GROUNDS

MECHANICALLY SECURED

GROUND: GREEN/YELLOW WIRE

SAME GAUGE AS OR BIGGER THAN SUPPLY

wiring and connection to the supply primary wiring
Wiring and connection to the supply – Primary Wiring -
  • All AC wires shall be double secured. Double securement can be met by:

Double crimp connector or

Single crimp connector and cable tie or

Single crimp connector and shrink sleeving.

  • AC wiring shall be rated for the maximum working voltage and current.
  • AC wiring shall be isolated from low voltage wiring or low voltage parts, this can be accomplished by:

Shrink sleeving the AC conductors or

By routing the AC conductors away from low voltage wires

and securing with cable ties or

By using UL1015 Reinforced Insulation wire.

resistance to fire and control of fire spreading
Resistance to fire and control of fire spreading
  • Enclosures, components, and other parts shall be constructed such that propagation of fire is limited. Flammability of enclosure, internal, and external parts shall be adequate for the use of that part.
  • Flammability ratings
  • 5VA – Most fire resistant
  • 5VB
  • V0
  • V1
  • V2
  • HB40
  • HB75 - Least fire resistant
  • Foamed materials:
  • HF-1
  • HF-2
  • HBF
resistance to fire and control of spread of fire
Resistance to fire and control of spread of fire
  • 60950-1
  • Fire enclosure openings shall be:
  • Top and side openings shall be:
  • less than 5mm in any dimension or
  • less than 1mm in width regardless of length or
  • meet the 5 projection rule.
  • There shall be no bottom openings (some exceptions allowed but difficult to meet)
methods for meeting fire requirements in 61010 1
Methods for Meeting Fire Requirements in 61010-1
  • Requirement: There shall be no spread of fire outside the equipment in Normal or Single Fault Conditions.
  • Methods of Compliance:
  • A: Testing in single fault conditions
  • B: Reducing sources of ignition within the equipment
  • C: Containing fire within the equipment should it occur
requirements for fire enclosure
Requirements for fire enclosure
  • - Components in primary circuit
  • - Components in secondary circuits that are not
  • supplied by LPS
  • - Components in secondary circuits supplied by LPS
  • but not on V-1 material
  • - Components with unenclosed arcing parts
  • - Insulated wiring
parts not requiring fire enclosure
Parts not requiring Fire Enclosure
  • - Motors
  • - Transformers
  • - Wiring and cabling insulated with PVC, TFE, PTFE,
  • FEP, neoprene or polymide
  • - Connectors in secondary circuits powered by less
  • than 15VA or LPS
  • - Components in secondary circuits supplied by LPS
  • and on V-1 material
  • - Components in secondary circuits supply by max
  • 15VA and on HB785 if <3mm or HB40 if >3mm.
plastic materials used for fire enclosure
Plastic materials used for fire enclosure
  • Movable equipment <18kg:

V-1 or pass A.2

HWI test (if <13mm from high temp parts)

  • Movable equipment >18kg or stationary equipment:
  • 5VB or pass A.1

HWI test (if <13mm from high temp parts)

  • Materials filling an opening in a fire enclosure:

V-1 or pass A.2

plastic materials used inside a fire enclosure
Plastic materials used inside a fire enclosure
  • Inside a fire enclosure:

V-2 or HF-2 or pass A.2

  • Exceptions:
  • Electronic components (IC’s, optos, etc.) mounted on V-1.
  • Wiring and connectors insulated with PVC, TFE, PTFE, FEP, neoprene, or polymide.
  • Clamps, cable ties.
  • Wire marked VW-1 or FT-1 or better.
  • Others….
plastic materials used outside a fire enclosure
Plastic materials used outside a fire enclosure
  • Material outside fire enclosure:
  • HB75 if <3mm or HB40 if >3mm or HBF or Glow Wire test at 550C
  • Connectors:
  • V-2 or pass A.2 or mounted on V-1 and be small or be in secondary circuit with max 15VA
  • Exceptions:
  • Electronic components (IC’s, optos, etc.) mounted on V-1.
  • Wiring and connectors insulated with PVC, TFE, PTFE, FEP, neoprene, or polymide.
  • Clamps, cable ties.
  • Others….
washington laboratories ltd
Washington Laboratories, Ltd.
  • Help you select the proper Directives and Standards to apply to your product.
  • Evaluate and test your product to the appropriate Safety Standard and offer solutions for non-compliances.
  • Provide product design assistance.
  • Obtain cTUVus, cCSAus, cULus, GS Mark, and other approvals.
  • WLL is a Partner Test Lab for TUV Rheinland for 60950-1, 61010-1, and 60065
washington laboratories ltd29