outline

outline. Configurations overview (Tom) Bathtub type: (top loading/intermediate temp. cavity support) Gas return pipe: LCLS-II/XFEL ( side loaded cryomodule / cold cavity support) Strong back PIP-II ( side loaded cryomodule / warm cavity support) Comparison table Detailed designs

Download Presentation

outline

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. outline • Configurations overview (Tom) • Bathtub type: (top loading/intermediate temp. cavity support) • Gas return pipe: LCLS-II/XFEL (side loaded cryomodule / cold cavity support) • Strong back PIP-II (side loaded cryomodule / warm cavity support) • Comparison table • Detailed designs • PIP-II details (Tom) • SNS design (Ed) (side loaded cryomodule / warm cavity support) • ESS design(side loaded cryomodule / warm cavity support) • IFMIF design (side loaded cryomodule / cold cavity support) • DONES improvement based on Ifmif design (top loading) • SARAF design (top loading)

  2. Cryomodule design: side / bottom / top loading IFMIF LIPAc: side loading FRIB: bottom loading ANL: top loading Triumf – Isac II: top loading PXIE HWR Cryomodule ATLAS Upgrade CERN HIE Isolde: top loading Top loading configuration more usual for low beta cavities N. BAZIN | WPENS 2nd Technical Meeting | October6th, 2016 | Page 2

  3. SNS Space Frame Design Ed Daly February 7, 2019 On behalf of JLab Team

  4. Introduction – Space Frame • ~1999 – For Jlab Upgrade Cryomodules, Mark Wiseman thought of applying the space frame concept used in the aerospace industry • Space frame is a fixture that supports the cold mass components in-situ and facilitates cryomodule assembly steps • Needed a method to support 8-cavity string having no intercavity bellows • As C100 design was developed by Eric Feldl, the space frame design was integrated as part of the internal assembly • In 2000, SNS design followed this design concept Test frame surrounding space shuttle during assembly C100 Cut-away View Space frame supports internal components Prototype Upgrade Space Frame on Assembly Rails

  5. SNS – High Level Design Requirements Space Frame • Operating temperature – at or near room temperature • Alignment • 0.5 mm in transverse, vertical and axial directions as part of CM assembly • 0.5 mm in transverse, vertical and axial directions as part of tunnel installation • Shipping loads • Vertical: +/- 4.0g • Beam-Axis: +/- 5.0g • Transverse +/- 1.5g Vacuum Vessel Thermal Shield Access Port Cold Mass SNS PPU CM Cross Section: Spaceframe unchanged from original SNS CM design

  6. SNS Medium Beta CM Space Frame / Thermal Shield Assembly on Tooling

  7. SNS – Support Scheme Nitronic rods (low heat leak, high tensile strength) restrain cavities - 2 axial, 8 radial per cavity Inter-cavity bellows Each cavity is fixed at FPC in axial direction Cold gate valve (connects to warm-cold beampipe)

  8. Space Frame - Design Features Side view showing ports, VV is transparent Nitronic Support Rods Spaceframe is locked to VV after installation Outer Magnetic Shield attaches to OD Alignment Steps – cavity flanges: Survey string on lollipops Transfer cold mass into space frame (shown) and align Fiducialize after installation into Vacuum Vessel using access ports and tooling Bottom section (orange) is removable in order to slide space frame over the string assembly

  9. ESS spaceframe: cryomodule overview

  10. ESS spaceframe: cross section

  11. ESS spaceframe: Support Scheme

  12. ESS Design Requirements • Operating temperature – at or near room temperature   spaceframe at 300K supporting each cavities with 8 Ti alloy rods • Alignment      +/- 1 mm transverse (horizontal2 + vertical2)1/2 +/- 2mm longitudinal     • Shipping loads  (based on XFEL experience) The cryomodule shall not be exposed to shocks exceeding 2.5g in all the 3 directions of the x-plane, y-plane and z-plane

  13. ESS ellipt. cryomtransportation coupler locked for transport Cavity transverse locking by design One axial locking per cavity to the Space frame (transportation only) Spaceframe fixed to vacuum vessel for transport

  14. IFMIF LIPAcCryomodule: cold mass insertion • Due to the couplers, the cold mass must be inserted in the vacuum vessel in two steps: • Horizontal sliding of the frame which is higher than its final position. The frame should be set up so that the couplers are facing the flanges of the vacuum tank. • Vertical motion of the frame until the coupler flanges touch the vacuum tank flanges. Cold mass Vacuum vessel N. BAZIN | WPENS 2nd Technical Meeting | October6th, 2016 | Page 14

  15. IFMIF: LIPAcCryomodule: cold mass insertion • When lowering the cold mass inside the vacuum vessel, the operators have to be sure that every interface flange of the power couplers properly mates with its corresponding flange. • This is also the case for the flange of the pumping line of the cavity string (not shown in the figure below). • The operators have also to check that the interface flange between the solenoid and the current lead package faces its corresponding flange of the vacuum vessel. • The operators have also to check that the interface flange of the beam valve faces its corresponding flange of the two doors. Many interfaces to control during this assembly step

  16. IFMIF: LIPAcCryomodule: cold mass insertion Many assembly steps have to be performed after the insertion of the cold in the vacuum vessel, with small access room for some operations. Example: Installation of the current leads: the welding of the solenoid package wires to the current lead busbars has to be performed through the cryomodule trapdoors. N. BAZIN | WPENS 2nd Technical Meeting | October6th, 2016 | Page 16

  17. IFMIF Design Requirements • Support temperature : 4K (from design to be verified) , thermal straps to helium cir. • Alignment: ± 1 mm and ± 10 mrad around the beam axis for solenoids ± 2 mm and ± 20 mrad around the beam axis for cavities

  18. DONES: Top loading cryomodule • As all the interfaces but the power couplers and the beam valves are with the top plate, the assembly process is simpler • Most of the work could be performed before the insertion in the vacuum vessel: • Completion of the helium circuitry with leak and pressure tests • Installation of the current leads • Cabling of the sensors and actuators • Installation of the multi layers insulation blankets • Installation of the thermal shield with leak and pressure tests • Less interfaces to monitor during the insertion steps: • interface flanges between the couplers and the vacuum vessel • interface flanges between the beam valves and the vacuum vessel N. BAZIN | WPENS 2nd Technical Meeting | October6th, 2016 | Page 19

  19. DONES: Top loading cryomodule Improvement of the assembly process • LIPAccryomodule: the titanium frame is used as support of the cavity string in clean room severe requirements on the manufacturing: • For clean room reasons, all the surfaces of the I-beams are machined before welding • After welding, the top surface of the frame are precisely machined (flatness requirement: 0.1 mm/m) • The minimum distance between the flanges of a solenoid and a cavity is 160 mm for a safe removal of the flanges used to position the components  constraints on the motion of the elements along the frame due to the vertical power couplers and the strengthening bars IFMIF LIPAc N. BAZIN | WPENS 2nd Technical Meeting | October6th, 2016 | Page 20

  20. DONES: Top loading cryomodule Design improvement to ease the assembly process • The frame is not used in clean room, but a trolley with rails and positioning post (as for XFEL and ESS cryomodule) Conceptual design of the tool used for the assembly of the ESS cavity string Cavity string to assemble in clean room • Assembly of the cavity string to the frame outside the clean room • Completion of the assembly N. BAZIN | WPENS 2nd Technical Meeting | October6th, 2016 | Page 21

  21. SARAF Low beta cryomodules CM3 CM4 CM1 CM2 • The twof first ryomodules (CM1 and CM2) are identical. • They house 6 bopt = 0.091, 176 MHz half-wave resonators and 6 focusing superconducting solenoids with steerers. • A 360 mm free space between the fifth cavity and the sixth solenoid package is left to facilitate the matching with next cryomodule. • This space could also possibly house an extra low beta cavity in case of need (CM2). SARAF-LINAC PDR WP5 | October 13th, 2015 | PAGE 22

  22. SARAF High beta cryomodules CM3 CM4 CM1 CM2 • The last two cryomodules (CM3 and CM4) are identical. • They house 6 bopt = 0.181, 176 MHz half-wave resonators and 4 focusing superconducting solenoids with steerers. SARAF-LINAC PDR WP5 | October 13th, 2015 | PAGE 23

  23. cryomodules main specification SARAF-LINAC PDR WP5 | October 13th, 2015 * To be confirmed to stay within Article 3.3 area of PED | PAGE 24

  24. SARAF Support Scheme • Support Frame addedfrom the top, after the string assembly • Vertical and horizontal tierods • C-shapedelement

  25. SARAF Design Requirements • Support Temperature: actively cooled to 4K (helium circuit welded to the support). Then we let the support thermalized to about 30K • Alignment : Cavities and solenoid package positioned within ±1 mm from theoretical linac axis. Cavities and solenoid package positioned within ±2 mm from theoretical longitudinal position. • Transport: Vertical : 3g Lateral : 1.5g Longitudinal : 5g

  26. Mitigation Actions Transportation to Israel • Transportation by sea = Cheapest solution but: • Several loadings/unloadings heavy shocks possible during transshipment • Coupler window failure or weakening due to fatigue (resulting from ocean swell) • Risk of contamination of the beam vacuum during shipment (long journey) Mitigation action: Transportation by plane Design complementary constraints: dimensions of the doors of the widespread 747-8F cargo plane: the nose door is 94 in. (239 cm) wide and 96 in. (244 cm) high, while the large side cargo door allows to charge 238.5 in. (606 cm) long and 96 in. (244 cm) wide loads SARAF-LINAC PDR WP5 | October 13th, 2015 H. Dzitko, SRF2015 | PAGE 27

  27. SARAF transportation • Transport solution not fully validated yet but the starting point is cold mass (CM) and vacuum vessel (VV) disassembled after cryo test and sent by plane. • Module has been designed for CM and VV separated solution this ease to fix sensitive parts of the cold mass (bellows, coupler, etc.). • Once delivered, inspections and tests will be easy

  28. Back-Up slides SarafCryomoduledesign CEA | 10 AVRIL 2012

  29. Design constraints • To limit the beam losses due to its high intensity: particularly restricted space for the component interfaces, which have been minimized as much as possible. • Beam dynamics lattice is indeed very short: only 340 mm space is allowed for the solenoid package (including the beam position monitors and the bellows), 280 mm for the low beta cavity and its tuning system and 410 mm for the high beta cavity and its tuning system. • These requirements define high constraints on the design of these components. Conceptual design of the low beta cryomodule (SDR SARAF-LINAC, December 2014) Conceptual design of the SDR is the starting point of this work. SARAF-LINAC PDR WP5 | October 13th, 2015 Conceptual design of the low beta cryomodule (PDR SARAF-LINAC, December 2013) | PAGE 30

  30. Cryomodule overview Even if the number of cavities and solenoids depends on the type of cryomodules, the principle is similar for both and the same design approach will be used. SARAF-LINAC PDR WP5 | October 13th, 2015 | PAGE 31

  31. Side / Bottom / top loading IFMIF: side loading FRIB: bottom loading Triumf – Isac II: top loading ANL: top loading Fermilab – SSR1: side loading / bottom support of the cavity string PXIE HWR Cryomodule ATLAS Upgrade Top loading configuration, more usual for low beta cavities, was chosen in December 2013 (PDR176) CERN HIE Isolde: top loading SARAF-LINAC PDR WP5 | October 13th, 2015 | PAGE 32

  32. SDR: Support of the cavity string • Like for the IFMIF cryomodule, the cavity string is supported by a stiff frame: • designed and fabricated in order to preserve the relative alignment during thermal cycling, • made of titanium to avoid magnetic issue. Conceptual design of the low beta cryomodule (PDR SARAF-LINAC, December 2013) Not possible to directly attach the cavities and the solenoids to the frame • 4 m long frame shrinkage: around 6 mm. • Must be compensated by the bellows of the couplers which are interfaced with the vacuum vessel (similar for the bellows of the current leads). • These ones shall already compensate the thermal shrinking of the coupler outer antenna (around 1 mm, perpendicular to the beam axis) and the possible manufacturing errors of the vacuum vessel. Toomanyconstraints on the bellows SARAF-LINAC PDR WP5 | October 13th, 2015 | PAGE 33

  33. SDR: Support of the cavity string Cavity fixed point on the invar rod Solution: leave the cavities and solenoids longitudinal position independent from the titanium frame. • Principle – similar to the IFMIF cryomodule: • C-shaped elements with needle rollers to allow the cavities or the solenoids to move longitudinally along the beam axis. • Loaded spring washer packages keep the pads in contact with the rollers regardless the thermal shrinking. • The elements of the string are attached to an invar rod whose thermal shrinking is low (-0.4 mm/m between 300K and 4K). • The invar rod is fixed on the middle of the titanium frame and sets the longitudinal positions of the elements. Invar rod Titanium frame Invar rod fixed point Sliding attachments to manage the differential thermal deformation between invar rods and frame SARAF-LINAC PDR WP5 | October 13th, 2015 | PAGE 34

  34. Supporting the cold mass • Requirements: • Shall sustain the weight of the devices with an accurate and reproducible positioning of the components of the cavity string along the beam axis of the accelerator. • Heat loads on the cold part as low as possible. • Several solutions are still under study for the cryomodule: using tie rods and suspended posts. • Configuration 1: using vertical tie rods • Similar to the IFMIF cryomodule and proposed in the SARAF-LINAC Project System Design Report. • Cold mass is hung to the top plate of the vacuum vessel thanks to vertical TA6V tie rods. • Four horizontal rods ensure the lateral position of the cold mass inside the vacuum vessel. • Tension load on each vertical titanium rod has to be adjusted to have a flat frame in order to keep the alignment of the cavity string • Beam axis is set below its nominal position to compensate the thermal shrinking of the titanium rods during the cool down of the cryomodule IFMIF cold mass with the vertical and horizontal rods SARAF-LINAC PDR WP5 | October 13th, 2015 | PAGE 35

  35. Supporting the cold mass • Configuration 2: using tilted struts • Cold mass is hung to the top plate of the vacuum vessel thanks to tilted struts. • No need of lateral struts. • Beam axis is set below its nominal position to compensate the thermal shrinking of during the cool down of the cryomodule CERN HIE Isolde Triumf – Isac II ANL: ATLAS Upgrade SARAF-LINAC PDR WP5 | October 13th, 2015 | PAGE 36

  36. Supporting the cold mass • Configuration 3: using antagonist tie rods • In order to compensate the upwards movement of the frame during the cool down due to thermal shrinking of the titanium rods, vertical rods connected to the bottom of the vacuum vessel are used. • Uses titanium alloy rods like the previous one. • Dimensions – length and diameter – of the rods pulling upwards shall be the same as the rods pulling downwards. Severe constraint for the design of the cold mass as the frame must be in the middle of the vacuum vessel (vertical position). SARAF-LINAC PDR WP5 | October 13th, 2015 | PAGE 37

  37. Supporting the cold mass • Configuration 4: using rigid suspended posts • Rigid posts used in the LHC quadrupole and in the TTF/XFEL/ILC cryomodule. • Several rigid posts made of isolative material with appropriate mechanical properties, a glass-fiber epoxy composite, G10, are used to support the cold mass. • Because of the longitudinally shrinking of the cold mass, one post is rigidly fixed to the top plate of the vacuum vessel while the others longitudinally slide. XFEL support post HWR015, IMP Y. He, “Progress of Chinese ADS Project”, SRF2015, SARAF-LINAC PDR WP5 | October 13th, 2015 | PAGE 38