An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Review of existing CTF3 BPM’s and related dataacquisition Lars Søby CTF3-CLEX meeting

  2. BPE • Electrostatic PU. • Ceramic tube containing 4 electrodes. 4 feed-thru • 2 units in Linac • High impedance buffer followed by standard acquisition system Lars Søby CTF3-CLEX meeting

  3. BPI • WCM type PU using current transformers. • Racetrack vacuum chamber. • 4 electrodes, no feed-thru. • Delay loop + Linac 19 units. No analogue electronics. • CR +TL1 27 units is foreseen. Standard acquisition system. • TL2 ?? Lars Søby CTF3-CLEX meeting

  4. BPM • WCM type PU using current transformers. • Circular vacuum chamber. • 8 electrodes, no feed-thru. • 23 units in the Linac. • CR +TL1 6 units is foreseen. • TL2 ?? • Standard acquisition system. Lars Søby CTF3-CLEX meeting

  5. BPR • Button PU and wave guide port. • Circular vacuum chamber. • 4 buttons with feed-thru. • 2 units in the Linac, 1 in the CT line. • CR 1 unit is foreseen. • TL2 ?? • Down mixing using 3GHz reference • Wave guide detector. • Standard acquisition system. Lars Søby CTF3-CLEX meeting

  6. WCM • 7GHz WCM. • Circular vacuum chamber. • 2 mm air gap. 8 feed thrus • 3 units in the Linac. • 1 unit at exit of delay loop. • 1 is foreseen for TL2 • Standard acquisition system for low frequencies. Lars Søby CTF3-CLEX meeting

  7. Layout of BPM acquisition system Equipment Room Tunnel Lars Søby CTF3-CLEX meeting

  8. Front-end electronics Lars Søby CTF3-CLEX meeting

  9. Layout of BPM acquisition system Equipment Room Tunnel Lars Søby CTF3-CLEX meeting

  10. Acquisition Hardware SIS 3300/20 VME module 8 channels @ 100/200 MHz 12 Bits (-2.5  2.5 V) Ext trigger Ext 96/192 MHz clock Lars Søby CTF3-CLEX meeting

  11. Thank you for your attention Lars Søby CTF3-CLEX meeting