Position sensitive scintillation detectors for the trigger system in the space experiment NUCLEON. Supervisors: Anatoliy I. Kalinin a Students: Irina Cioara b Alexandra Chilug b a Joint Institute for Nuclear Research, Dubna,Russia b University of Bucharest, Romania

Download Presentation

Position sensitive scintillation detectors for the trigger system in the space experiment NUCLEON

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Position sensitive scintillation detectors for the trigger system in the space experiment NUCLEON Supervisors: Anatoliy I. Kalinin a Students: Irina Cioara b Alexandra Chilug b a Joint Institute for Nuclear Research, Dubna,Russia b University of Bucharest, Romania Dzhelepov Laboratory of Nuclear Problems

  2. Cosmic rays Were discovered by Victor Hess in 1912 • They are energetic charged subatomic particles, originating from outer space. They may produce secondary particles that penetrate the Earth's atmosphere and surface. • The NUCLEON experiment is aimed at studying cosmic rays that have energies between 1011- 1014 eV. • The TUS experiment is aimed at studying cosmic rays that have ultra high energy, above 5*1019 eV. The used method is an indirect one, that does not remember the primary particle.

  3. NUCLEON • The main idea of the NUCLEON project is to design and to create a scientific device with large aperture and a relatively light weight for measure elemental spectra of cosmic rays in a wide energy range E ~ 1011- 1014 eV. • The method is based on event by event measurement of spatial distribution of the charged and neutral secondary particles which were produced in the inelastic nuclear interaction in the target of the detector and have passed through layers of silicon micro strip detectors and thin converters to produce e- e+ pairs of the secondary gammas. This technique is known as KLEM (Kinematic Lightweight Energy Meter).

  4. KLEM[Kinematic Lightweight Energy Meter] • The main objective of the KLEM instrument is direct measurement of the elemental energy spectra of high-energy (1011-1016eV ) cosmic ray in space. • The basis of the KLEM method is energy determination by measuring the number and the angular distribution of secondary particles produced in a target. • The energy of a primary particle is calculated using the following function: Ni= number of secondary particles registered in strip i ηi= pseudorapidity xi= distance of strip i from the point of intersection of the extrapolated primary particle trajectory with the detector plane h= the distance between the detector plane and the midle of the target

  5. KLEM Advantages of KLEM method: • a large aperture • a lightweight device (it does not need a thick absorber) • has easy read out of information (thanks to the use of silicon microstrip detectors) • long duration exposures in orbit • measurement of an individual energy spectra with single technique over a very wide energy range

  6. NUCLEON Structure

  7. P-16 P1 A PMT+ IVN MPMT P-32 X A Fibers PMT + IVN P-16 P1 A PMT + IVN MPMT Y A PMT+ IVN Block diagram of the plane Trigger system The goal of the trigger system is the selection and rejection of data flux to a limited volume that can be transferred to the ground data acquisition and control center for further offline analysis. COMPARATOR

  8. Scintillator detectors - basic instruments for registration of cosmic rays and other radiations. Amplifier A CC COMPARATOR PMT The scintillator converts the falling radiation into a short pulse of visible light. The photomultiplier converts the collected light from the scintillator into electrical signal and amplifies it as much as possible. In the NUCLEON project vacuum photomultipliers are used. Fiber Scintillator

  9. PMT and SiPM Silicon PhotoMultiplier Vacuum Photomultiplier

  10. Advantages for Silicon Photomultipliers: • Applicability in many different fields (high energy physics calorimetry, astrophysics, medical imaging) • Low voltage supply (<100 V) • Insensitivity to magnetic field • High gain ~ 106 • Better one-electron resolution The general equivalent circuit of the SiPM

  11. Thank you for your attention!