1 / 17

UV/Visible Spectroscopy

UV/Visible Spectroscopy. UV/VIS Spectroscopy. What does a UV/Vis Spectrometer Measure?. In practice P o is estimated by a “blank” which accounts for reflection and scattering losses. UV/VIS Spectroscopy.

lilac
Download Presentation

UV/Visible Spectroscopy

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. UV/Visible Spectroscopy

  2. UV/VIS Spectroscopy What does a UV/Vis Spectrometer Measure?

  3. In practice Po is estimated by a “blank” which accounts for reflection and scattering losses. UV/VIS Spectroscopy Transmittance (T) is defined as the amount of light passing through the sample solution (P) divided by the amount of incident radiation (Po) T = P/Po

  4. UV/VIS Spectroscopy As the radiation is absorbed in the sample, the total intensity of radiation is reduced as it travels through the sample. This results in a non-linear relationship between transmittance and concentration.

  5. UV/VIS Spectroscopy Absorbance (A) is based on the amount of light absorbed by the solution and is defined as the log of the inverse of the transmittance. A = log10(1/T)

  6. UV/VIS Spectroscopy Within limits, the relationship between absorbance and concentration is linear.

  7. UV/VIS Spectroscopy Beer’s law or the Beer-Lambert law A = bc  is the molar absorptivity with units of (L/mol-cm) b is the path length of the sample ie. the inside cross section of the sample cuvette (cm) c is the concentration of the compound in solution in (mol/L)

  8. UV/VIS Spectroscopy Increased interaction between the molecules can affect absorbance at high concentrations. Electrolytes can also alter the molar absorptivity of the analyte by electostatic interactions. Molar absorptivity is also altered by the refractive index of the solution.

  9. UV/VIS Spectroscopy When an analyte associates or dissociates in solution producing products with different absorption spectra, deviations from Beer’s law can be observed if the equilibrium shifts at different concentrations. Hindicator H+ + Indicator-

  10. UV/VIS Spectroscopy Other causes of deviation from Beer’s law: Radiation is not monochromatic Stray radiation Absorbance readings less than 0.10 and higher than 1.5 can contain significant error and should be avoided.

  11. Spectra of Compound 1 Spectra of Compound 2 UV/VIS Spectroscopy Quantification of Two Compounds Absorbance Wavelength

  12. UV/VIS Spectroscopy Quantification of Two Compounds The method to determine the concentrations of two compounds (a & b) in a mixture involves the simultaneously solution of the following two equations: At wavelength 1 A1 = ea1ca + eb1cb At wavelength 2 A2 = ea2ca + eb2cb

  13. UV/VIS Spectroscopy A = bc Quantification of Two Compounds At wavelength 1 A1 = ea1ca + eb1cb At wavelength 2 A2 = ea2ca + eb2cb Where ea1, eb1, ea2, eb2 are the molar absorptivities for the two compounds at the two wavelengths which are determined from standard solutions - and ca and cb are the concentrations of the two unknown compounds.

  14. UV/VIS Spectroscopy Quantification of Two Compounds EXAMPLE

  15. multiply equation (2) by 6.73, giving equation (4): (3) 0.870 = 11636ca + 17949cb (4)2.436 = 178877ca + 17949cb UV/VIS Spectroscopy Quantification of two compounds Set up equations: (1) 0.870 = 11636ca + 17949cb (2)0.362 = 26579ca + 2667cb

  16. UV/VIS Spectroscopy Quantification of two compounds Set up equations: (3) 0.870 = 11,636ca + 17,949cb (4)2.436 = 178,877ca + 17,949cb Subtract (3) from (4), giving equation (5): (5) 1.566 = 167,240ca

  17. UV/VIS Spectroscopy Quantification of Two Compounds (5) 1.566 = 16724ca Solve for ca: (6) ca = 9.36 x 10-6 moles/L = concentration of compound a Substitute value from (6) into equation (1) and solve for cb: 0.870 = 11636(9.36 x 10-6) + 17949cb 0.870 = 0.109 + 17949cb 0.760 = 17949cb cb = 4.24 x 10-5moles/L = concentration of compound b