First measurements Investigations into the Curing of Hysol 9396 using Differential Scanning Calorimetry. (Tim). Differential Scanning Calorimetry. Study how fully-cured Hysol9396 gets after different cure times and with different cure temperatures

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about '(Tim)' - kipp


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
slide1

First measurements Investigations into the Curing of Hysol 9396 using Differential Scanning Calorimetry

(Tim)

differential scanning calorimetry
Differential Scanning Calorimetry
  • Study how fully-cured Hysol9396 gets after different cure times and with different cure temperatures
    • Eg. How well cured is it after 1 day at 22C?
    • NB. Hysol received March 2010 !
  • Measurements
    • Dynamic: Measure heat flow into/out of sample during a temperature ramp (eg 0 to 220C)
      • Measures the maximum possible heat associated with curing exotherm.
    • Static: Measure heat flow into /out of sample at a fixed temperature followed by dynamic scan.
      • Measures heat associated with curing at fixed temperature.
    • By combining both types of measurement the degree of cure for a given process can be determined.
summary
Summary
  • Typical heat released in a dynamic scan of un-cured Hysol is 560 ± 25 J/g (5%). This compares reasonably well with the data from the Wright Laboratory report.
    • “CHARACTERIZATION OF EA9396 EPOXY RESIN FOR COMPOSITE REPAIR APPLICATIONS”
  • For room-temperature cured Hysol (1-4 days), the un-released heat is typically 190J/g implying that only 66% of the available heat-release has occurred. (WL-TR-92-4060 quotes 170J/g released after 7 day cure at room temperature)
  • Room-temperature cured sample show indications of melting at about 60C
  • There is some degree of correlation between curing time and heat release/re-melt temperature.