870 likes | 2.22k Views
Seminar on Improved Power Quality AC-DC Converters with High Frequency Transformer Isolation. By Prof. Bhim Singh Department of Electrical Engineering Indian Institute of Technology Delhi Hauz Khas, New Delhi-110016, India email:bhimsinghr@gmail.com Ph.: (91)-011-2659-1045. Classification.
E N D
Seminar onImproved Power Quality AC-DC Converters with High Frequency Transformer Isolation ByProf. Bhim Singh Department of Electrical Engineering Indian Institute of Technology Delhi Hauz Khas, New Delhi-110016, Indiaemail:bhimsinghr@gmail.comPh.: (91)-011-2659-1045
Improved Power Quality AC-DC Converters with High Frequency Transformer Isolation • The control of DC-DC converter is done such as the input current wave shaping is achieved for AC-DC Diode converter. • The DC-DC converter can be operated in both DCM and CCM mode. • The control technique for DCM and CCM are different. • It works as voltage follower in DCM mode and there is no need of input voltage & current sensing for power factor correction.
Applications • DC Power Supplies, • Telecommunication Power Supply, • Improved Power Factor ballast, • Power Supplies for equipments like computers, medical equipments, printers, scanners etc. • Drives Applications with Power Factor Improvement at AC side, • Electrical Welding, • Lighting such as ballasts, CFL etc.
Single-Phase Buck Boost Flyback AC-DC ConverterAverage current mode control in CCM operation
Single-Phase Buck Boost Flyback AC-DC ConverterFLYBACK Converter in DCM
Single-Phase Buck Boost Flyback AC-DC ConverterDesign of Flyback Converter in DCM
Single-Phase Buck Boost Flyback AC-DC ConverterDesign of Flyback Converter in DCM
Single-Phase Buck Boost Flyback AC-DC ConverterDesign of Flyback Converter in DCM
Single-Phase Buck Boost Flyback AC-DC ConverterDesign of Flyback Converter in DCM and CCM
Single-Phase Buck Boost Flyback AC-DC ConverterDesign of Flyback Converter in DCM and CCM
Single-Phase Buck Boost Flyback AC-DC ConverterDesign of Flyback Converter in DCM and CCM
Single-Phase Buck Boost Flyback AC-DC ConverterSpecifications
Single-Phase Buck Boost Flyback AC-DC Converter Source voltage and current in DCM at 100% load Steady state output voltage in DCM at 100% load
Single-Phase Buck Boost Flyback AC-DC Converter Source voltage and current in CCM at 100% load Steady state output voltage in CCM at 100% load
Single-Phase Buck Boost Flyback AC-DC Converter TABLE I Comparisons of Flyback Converter Operation in DCM and CCM
Single-Phase Buck Boost Flyback AC-DC Converter Vs (V), is(A) Vdc (V) Idc (A) Test results of AC mains voltage, AC mains current, output DC voltage and output DC current waveform of AC-DC flyback converter for load perturbation response on equivalent resistive load (60W to 200W to 60W). (Scale on X-axis 1div=20ms, Y-axis channel-1 1div =85V, channel-2 1div =5A, channel-3 1div= 100V, channel-4 1div= 2A)
Single-Phase Cuk AC-DC ConverterInductors voltage and current waveforms in DCM
Single-Phase Cuk AC-DC ConverterInductors voltage and current waveforms in CCM
Single-Phase Cuk AC-DC ConverterAverage and peak currents in the semiconductors and input inductor
Single-Phase Cuk AC-DC ConverterAverage and peak currents in the semiconductors and input inductor
Single-Phase Cuk AC-DC Converter Design Description in DCM and CCM
Single-Phase Buck-Boost Cuk AC-DC Converter Source voltage and current in DCM at 100% load Steady state output voltage in DCM at 100% load
Single-Phase Buck-Boost Cuk AC-DC Converter Source voltage and current for 100% load in CCM Steady state output voltage in CCM at 100% load
Single-Phase Buck-Boost Cuk AC-DC Converter TABLE I Comparisons of Cuk Converter Operation in DCM and CCM at Full Load
Single-Phase Buck-Boost Cuk AC-DC Converter Vs (V), is(A) Vdc (V) Idc (A) Test results of AC mains voltage, AC mains current, output DC voltage and output DC current waveform of AC-DC cuk converter for load perturbation response on equivalent resistive load (60W to 200W to 60W). (Scale on X-axis 1div=20ms, Y-axis channel-1 1div =175V, channel-2 1div =5A, channel-3 1div= 100V, channel-4 1div= 1.75A)