1 / 30

ME 322: Instrumentation Lecture 31

ME 322: Instrumentation Lecture 31. April 9 , 2014 Professor Miles Greiner. Announcements/Reminders. This week: Lab 9.1 Open-ended Extra-Credit LabVIEW Hands-On Seminar Extra-Credit Friday , April 18, 2014, 2-4 PM, Place TBA Sign-up on WebCampus

Download Presentation

ME 322: Instrumentation Lecture 31

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ME 322: InstrumentationLecture 31 April 9, 2014 Professor Miles Greiner

  2. Announcements/Reminders • This week: Lab 9.1 Open-ended Extra-Credit • LabVIEW Hands-On Seminar • Extra-Credit • Friday, April 18, 2014, 2-4 PM, Place TBA • Sign-up on WebCampus • If enough interest then we may offer a second session • Noon-2 • HW 10 due Friday • I revised the Lab 10 Instructions, so please let me know about mistakes or needed clarifications. • Did you know? • HW solutions are posted on WebCampus • Exam solution posted outside PE 213 (my office)

  3. Lab 10 Vibration of a Weighted Cantilever Beam LE LB • Accelerometer Calibration Data • http://wolfweb.unr.edu/homepage/greiner/teaching/MECH322Instrumentation/Labs/Lab%2010%20Vibrating%20Beam/Lab%20Index.htm • C = 616.7 mV/g • Use calibration constant for the issued accelerometer • Inverted Transfer function: a = V/C • Measure: E, W, T, LB, LE, LT, MT, MW • Estimate uncertainties of each Clamp MW W T E (Lab 5) Accelerometer LT MT

  4. Table 1 Measured and Calculated Beam Properties • The value and uncertainty in E were determined in Lab 5 • W and T were measured using micrometers whose uncertainty were determined in Lab 4 • LT, LE, and LB were measured using a tape measure (readability = 1/16 in) • MT and MW were measured using an analytical balance (readability = 0.1 g)

  5. Figure 2 VI Block Diagram

  6. Figure 1 VI Front Panel

  7. Disturb Beam and Measure a(t) • Use a sufficiently high sampling rate to capture the peaks • fS> 2fM • Looks like • Expect , • Measure f from spectral analysis ( fM) • Find b from exponential fit to acceleration peaks

  8. Time and Frequency Dependent Data • http://wolfweb.unr.edu/homepage/greiner/teaching/MECH322Instrumentation/Labs/Lab%2010%20Vibrating%20Beam/Lab%20Index.htm • Plot aversus t • Time increment Dt = 1/fS • Plot aRMSversus f • Frequency increment Df= 1/T1 • Measured Damped (natural) Frequency, fM • Frequency with peak aRMS • Uncertainty • Exponential Decay Constant b (Is it constant?) • Show how to find acceleration peaks versus time • Use AND statements to find accelerations that are larger than the ones before and after it • Use If statements to select those accelerations and times • Sort the results by time • Plot and create new data sets before and after 2.46 sec • Fit data to y = Aebx to find b

  9. Figure 4 Acceleration Oscillatory Amplitude Versus Frequency • The sampling period and frequency were T1= 10 sec and fS = 200 Hz. • As a result the system is capable of detecting frequencies between 0.1 and 100 Hz, with a resolution of 0.1 Hz. • The frequency with the peak oscillatory amplitude is fM = 8.70 ± 0.05 Hz. This frequency is easily detected from this plot.

  10. Fig. 5 Peak Acceleration versus Time • The exponential decay changed at t = 2.46 sec • During the first and second periods the decay rates are • b1 = -0.292 1/s • b2 = -0.196 1/s

  11. Predictdamped natural frequency f from mass, dimension and elastic modulus measurements • How to find equivalent (or effective) mass MEQ, damping coefficient lEQ, and spring constant kEQ for the weighted and damped cantilever beam?

  12. Equivalent Endpoint Mass LE LB Clamp • Beam is not massless, so its mass affects its motion and natural frequency • mass of weight, accelerometer, pin, nut • Weight them together on analytical balance (uncertainty = 0.1 g) LT MT ME Beam Mass MB

  13. Intermediate Mass, • How to find uncertainty in MEQ? • Power Product or Linear Sum? • Power product or linear sum? • Power product or linear sum? • Power product or linear sum?

  14. Uncertainty

  15. Beam Equivalent Spring Constant, KEQ F LB • From Solid Mechanics: • E = Elastic modulus measured in Lab 5 • Power product? d

  16. Predicted Frequencies • Undamped • Power Product? • Damped • Power product? • If , then , and

  17. Table 2 Calculated Values and Uncertainties • The equivalent mass is not strongly affected by the intermediate mass • The predicted undamped and damped frequencies, fOP and fP, are essentially the same (frequency is unaffected by damping). • The confidence interval for the predicted damped frequency fP = 9.0 ± 0.2 Hz does not include the measure value fM= 8.70 ± 0.05 Hz.

  18. Measurements and Uncertainties • Lengths • W, T, wW, wT: Lab 4 • LT, LE, LB: Ruler w = 1/16 inch • Masses • MT Total beam mass • MW End components measured together • Uncertainty 0.1 g

  19. Lab 10 Vibration of a Weighted Cantilever Beam http://wolfweb.unr.edu/homepage/greiner/teaching/MECH322Instrumentation/Labs/Lab%2010%20Vibrating%20Beam/Accelerometer.pdf

  20. Measure a(t) • Dominant frequency ~ 10 Hz • Sampling rate: fS ~1000 Hz (to reliable observe peaks) • Sampling time: T1 ~10 sec (to resolve dominant frequency to with 0.1 • Find damping coefficient and damped natural frequency and compare to predictions • How to predict? t (s) Fit to data: find b and f

  21. Predicted behavior Prediction: a(t) = 0 What are the effective values of m, k,  ? ME Equivalent Point end Mass Uniform MB MACC = mass of accelerometer, pin, nut

  22. Lab 10 F Beam Spring ConstKeq d Beam cross-section moment of Inertia Determined E and its uncertainty in Lab 4 (you will be given the same beam) Lengths W, T, WW, WT LT, LE, LB - ruler W0 = ± Lab 4 • inch Measure with a ruler in this lab, ± 1/16 inch Masses MT ≡ Beam total mass MW ≡ End components – Mass, nut, bolt, accelerometer

  23. Lab 10 Modulus from Lab 4 E, WE Power Product

  24. Uncertainty

  25. Predicted Undamped Frequency

  26. Predicted Damped Frequency 𝜆 = ? = f(Frictional Heating, Fluid Mechanics, Acoustics) • Hard to predict, but we can measure it.

  27. Predicted Damped Frequency If then

  28. VI • Statistics, time (frequency) of Maximum

More Related