1 / 13

Update on Thin Silicon Detectors Results

Update on Thin Silicon Detectors Results. G. Casse , P. Dervan , D. Forshaw, A. Greenall , T. Huse , I. Tsurin , M. Wormald. OUTLINE:. Silicon detectors are the choice for the present and future High Energy and, increasingly, Nuclear Physics experiments for Vertexing and Tracking.

ifama
Download Presentation

Update on Thin Silicon Detectors Results

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Update on Thin Silicon Detectors Results G. Casse, P. Dervan, D. Forshaw, A. Greenall, T. Huse, I. Tsurin, M. Wormald G. Casse,21st RD50 workshop, CERN 14-16 Nov.

  2. OUTLINE: Silicon detectors are the choice for the present and future High Energy and, increasingly, Nuclear Physics experiments for Vertexing and Tracking. The request for reducing the mass of these sensors, for a number of Physics reasons in the various application fields, get more and more pressing. Radiation tolerance is one of the aspects that these lower mass sensors will need. Here I describe the radiation tolerance of different thicknesses silicon micro-strip sensors. G. Casse,21st RD50 workshop, CERN 14-16 Nov.

  3. Low mass: a real need Future Vertex and Tracker detectors at the HL-LHC E+-e- colliders LHeC colliders Nuclear physics experiments B-factories .... All these experiments would benefit (and some strictly require) very low mass sensors. G. Casse,21st RD50 workshop, CERN 14-16 Nov.

  4. The method Sensors made by Micron Semiconductor on 4” wafers with thicknesses 50, 100, 140, 300 mm. 1x1 cm2, 80 mm pitch, n-in-p devices. The 50 mm thick would break (mechanically) when attached to the cooling block due to the different CTE. No measurements available after irradiation (when cooling is needed). Analogue information from the Alibava board (equipped with Beetle chip) Mip signal from 90Sr source Irradiations performed in the JSI Ljubljana research nuclear reactor G. Casse,21st RD50 workshop, CERN 14-16 Nov.

  5. Measurements before irradiation Charge Collection vs Bias (CC(V)) for the 50, 100, 140, 300 mm un-irradiated sensors. As expected the signal varies linearly with thickness Noise for un-irradiated detectors of various thicknesses. G. Casse,21st RD50 workshop, CERN 14-16 Nov.

  6. Degradation of the CC(V) with fluence 2x1015neq cm-2 Notice that the CC(V) for the 140mm thick sensor exceeds the expected charge ionised by a mip in that thickness of silicon. G. Casse,21st RD50 workshop, CERN 14-16 Nov.

  7. Degradation of the CC(V) with fluence 5x1015neq cm-2 G. Casse,21st RD50 workshop, CERN 14-16 Nov.

  8. Degradation of the CC(V) with fluence 1x1016neq cm-2 2x1016neq cm-2 G. Casse,21st RD50 workshop, CERN 14-16 Nov.

  9. Degradation of the CC(V) with fluence at 600 and 1000V 140 µm 300 µm 100 µm G. Casse,21st RD50 workshop, CERN 14-16 Nov.

  10. Degradation all thicknesses 1000 V 600 V G. Casse,21st RD50 workshop, CERN 14-16 Nov.

  11. Currents after the various fluences G. Casse,21st RD50 workshop, CERN 14-16 Nov.

  12. Noise G. Casse,21st RD50 workshop, CERN 14-16 Nov.

  13. CONCLUSIONS Thin silicon sensors is an available technology. Pixel and microstrip sensors can be produced down to at least 50mm thickness. It has been shown that thin sensors are offering advantages in term of radiation hardness with hadron irradiation. These advantages are substantial above 5E15 neq cm-2. At doses below this (large) value, the 300 mm thick devices appear to perform similarly to the thinner sensors both in term of charge collection and reverse current. They have slightly reduced noise due to the lower input capacitance. At extreme doses the thin sensors offer rather consistent advantages, increasing the signal collected at ‘lower’ voltages. It has been shown that 100 mm thick sensors can detectably outperform the 140 mm thick ones. Thinner sensors have not been measured after irradiation due to mounting problems and operation in cold. These measurements are planned soon to provide reference data for the thin sensor option after large hadron doses. G. Casse,21st RD50 workshop, CERN 14-16 Nov.

More Related