1 / 16

RF Power System: power source, distribution

RF Power System: power source, distribution. Paul Drumm RAL. Ambitious title!. RF Baseline Design. RF Power Design driven by cost issues (no funds for a new system) Optimal – one amplifier per cavity 2 Amplifiers from LBNL = 4 MW total 1 or 2 Amplifiers from CERN = 4 MW total

Download Presentation

RF Power System: power source, distribution

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. RF Power System: power source, distribution Paul Drumm RAL Ambitious title!

  2. RF Baseline Design • RF Power Design driven by cost issues (no funds for a new system) • Optimal – one amplifier per cavity • 2 Amplifiers from LBNL = 4 MW total • 1 or 2 Amplifiers from CERN = 4 MW total • If 1 amplifier – needs a bigger drive? • Spare TH116 Tubes from ISIS • Split or more amplifiers? • Circulator – cavity ↔ amplifier isolation • Hybrid device - possibly cheaper – some coupling? • Assume that we do R&D (trials) when we have the equipment • Need both cavities and one amplifier circuit • Test out a hybrid circuit driving two cavities

  3. Progress since October CM • December LBNL • Discussed shipping equipment to RAL • Two 2 MW power amplifier circuits • Three (300kW) driver circuits • 4616 test stand • LBNL loan – to be written off (eventually) • MoU to be signed

  4. … December • At LBNL • Stripping down for transport • Cleaning • Packing • Shipping…

  5. LBNL Power Amps

  6. 300 kW Driver Amplifier

  7. 4616 Test box

  8. Staff… • Roy Church • Used up quota of days • No Roy till April • RF group at the Daresbury SRS • Mike Dykes (group leader) • Andy Moss (senior RF Engineer) • plus two more • MD & AM are here… ASTeC

  9. Plan for Early 2004 • Limited funds • Berkeley RF system to DL • Strip down and make a technical assessment of the equipment • Cost to refurbish • Confirm equipment is serviceable • 6 month overlap with Roy • Review RF design in the light of CERN RF proposal

  10. For Late FY 2004 • Setting up a test-stand at DL • Hall and facilities available • Need to have got through GW2 • i.e. be in full funding mode

  11. RF Power Systems • 8 MW of RF Power @ 1Hz and 1 ms <8kW> • Expensive to buy new • 201.25 MHZ common to old linacs • LBNL, CERN, ISIS, KEK, Los Alamos • 4 MW from LBNL (2x2MW) + ISIS valves • 4 MW from CERN + new valve ? • How to transmit the power ? • Cheaper, hybrid • Expensive, low risk

  12. Split – Circulator - RF Scheme R.F. LEVEL SUM R.F.LEVEL PHASE SHIFTER 70db COUPLER CIRCULATOR CAVITY TH116 2.5MW 4616 250kW SOLID STATE DRIVER F R MATCHED POWER SPLITTER LOAD CAVITY PHASE TUNE ERROR PHASE DET 70db COUPLER CIRCULATOR CAVITY F R R.F. LEVEL AND PHASE CONTROL LOAD TUNE ERROR CAVITY PHASE PHASE DET 33kV H.T. R.F. SOURCE 18kV H.T.

  13. Baseline ? Master Oscillator 4 MW Transmitter 2 MW Transmitter 2 MW Transmitter 201 MHz Cavity Module 201 MHz Cavity Module 3 db Hybrid & Load Matched Splitter Circulator & Load

  14. ISIS Linac - RF System

  15. TH116 • Thales 5 MW tube • ISIS uses 1 or 2 tubes per year • Few customers for this tube • Thales: • success in small numbers not good • looking at large orders 10-20 tubes • Alternative tubes (?) 2 MW – splitting…

  16. X-Ray Shielding – Conditioning/Running Control Rooms