html5-img
1 / 40

The Future in Energy Savings

The Future in Energy Savings. GREEN TECHNOLOGY AT ITS BEST EE Green is proud to offer EPIC line of electric energy solutions. The EPIC is a proven electrical device Intelligently employs the patented Iterative Transformer technology to: Auto sensing on your consumption

harsha
Download Presentation

The Future in Energy Savings

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. The Future in Energy Savings

  2. GREEN TECHNOLOGY AT ITS BEST EE Green is proud to offer EPIC line of electric energy solutions. The EPICis a proven electrical device Intelligently employs the patented Iterative Transformer technology to: Auto sensing on your consumption Simultaneously solve multiple power quality problems Equals out power legs Reducing customer site electrical consumption (kWh) Lowers your electric bill

  3. UNITED STATES of AMERICA 4 TRILLION kWh PER YEAR

  4. PEOPLE’S REPUBLIC of CHINA 2.9 TRILLION kWh PER YEAR

  5. EUROPEAN UNION 2.8 TRILLION kWh PER YEAR

  6. WORLDWIDE CONSUMPTION OF ELECTRICTY TRILLION kWh per YEAR POTENTIAL SAVINGS: $135B/YR

  7. U.S.A. ELECTRICAL CONSUMPTION BY CATEGORY BILLIONS

  8. WORLDWIDE TARGET MARKET TOTAL TARGET MARKET $221 B

  9. Key Drivers What percentage of installations today have: • power quality problems that the EPIC technology can address? • application profiles (steady-state demand) that meet the product design?

  10. Key Drivers • If the product can be better understood and enhanced to address more of the target market, a higher percentage of the market can be addressed • Most consumers want to see a less than two-year payback on an investment, with one year being optimal. Utility co-sponsorship can aid this substantially.

  11. How it Works In the real world, power is far from perfect Clean Electricity has a perfect sine wave

  12. How it Works In the event of a spike, it is suppressed, saving money and saving equipment In the event of a lag, stored energy fills the gap, so it is suppressed, saving money and saving equipment

  13. Consumer’s Electrical Utility Pain State governments are uncapping electrical utility rates which results in dramatically increased utility rates for consumers (reference Texas dereg Jan 07, kWh rate doubled by May 08) Electrical Utility Grid Residential Consumers Commercial Consumers Power Sub Station Office Buildings Manufacturing • Utility owns grid • Utility controls grid • Poor power quality = • Inefficient delivery Government C-Store • Escalating electric bills • Peak usage billing (kWh) • No lightning/surge protection • Escalating electric bills • Combination of Peak Billing, • Demand Charge, Power Factor • Surcharge & Average Usage • No lightning/surge protection • No protection from harmonic • distortion, voltage sag etc.

  14. Existing Electrical Reduction Strategy Manufacturing / Commercial Residential “Turn the lights off” Replace all incandescent bulbs with energy efficient CFL bulbs Purchase Energy Star Rated Appliances Provide own lightning surge protection Protect expensive equipment from harmonic distortion (computers, VFD’s compressors) Pay more for efficient equipment Business Continuity Current Solutions Fall Short Others Nothing we can do to reduce dependence on utility provider (nature of our business) Minimal reductions are better than nothing Invest in equipment specific protection ENERNOC remote demand side energy management Office Buildings Encourage work from home programs “Turn the lights off” Invest in ‘Big Ticket” customized Demand Side Energy Management Systems – carry initial cash out lay + annual recurring

  15. EE Green / EPIC Solution Proven to reduce billable kWh Scalable based on energy consumption Combines Electrical Protection + PF Correction if needed + Energy Savings in one innovative product Makes your entire office facility Energy Efficient Single Utility Provider Large Enterprise Small Enterprise Residential EPIC R100 EPIC 300 EPIC 500

  16. EPIC – A Winning Solution

  17. Product Description • (EPIC) TECHNOLOGY • All-in-One Solution providing phase balancing, power savings, lightning/surge protection, harmonic reduction, and demand reduction • Iterative controller magnetic reactor • Single unit per main (typical) • Compatible with all voltages (up to 600v) • Simple to install and small form factor • Connects to electrical panel in parallel • No maintenance required – 100% Solid State • Water, Moisture, Dust & Tamper Proof • UL and CSA approved • Patented in the USA and in 72 countries • Typical ROI (18 to 36 months)

  18. Wilkes University verification Tested the EPIC R100 in the lab and provided a detailed report showing average kW savings greater than 30% William Patterson University (New Jersey) Installed EPIC 600 within 5 story office building. Facility has in-house Energy Management System to validate savings of 17% New Jersey Sports & Exposition Authority - IZOD Center - installed & tested 2 EPIC 450’s and 2 EPIC 600’s. Savings up to 28%. White Rose – owned by DiGorgio Corp. $1.1MM annual utility billing. Beta Test site 46 months and running. 3 EPIC 600s, verified 12% annual savings Does the EPIC really work?

  19. “The EPIC has saved us thousands of dollars in the short time it’s been here.” –Paul Teutul, Sr. 29.2% - 36.6% reduction in kW –Wilkes University

  20. Client Data & Testimonials Orange County Choppers - “the EPIC has saved us thousands of dollars in the short time it’s been here.” (Paul Teutel, Sr.) V Force Customs - “the electric bill for the shop was less than the bill for the office.” Wilkes University - 29.2% - 36.6% reduction in kW

  21. EPIC Set Up AC Power In Main Panel EPIC spare breaker • EPIC connects, in parallel, to a spare breaker in the main panel on the LOAD Side. • A good ground is essential to EPIC operation • EPIC acts as the least resistive load on the network in order to condition power in the facility. • EPIC is sized for either 240 VAC, 208 VAC, or 480 VAC. • As a facility grows, additional “EPIC”s can be added to meet demand without losing previous investment. • Easy to install by a certified Electrician! Load 1 Load N

  22. EPIC Operation AC Power In EMI Filter Harmonic Filter TVSS Iterative Control Transformer Storage 1 Surge Suppression and Harmonics all sent to earth ground Voltage Drop to Reduce Current and Phase Balancing Power Factor Correction + TVSS Filter,KVAR, Harmonic Filter, Storage 2 • Iterative Magnetic Technology filters out all surge /lightning and harmonics and sends to ground system. • It also eliminates all surge/harmonics to Storage 2 in order to • ensure maximum operation. • EPIC also greatly reduces in-rush conditions by clipping the peak demand.

  23. Lehigh University • Lehigh University Enterprise Systems Center has verified • The manufacture patents are internally consistent with EPIC Product Line • Device performs as claimed both physically & mathematically • Lehigh University is authoring • A simulation model for both Residential & Commercial Units • Practice & procedural documentation for • Sizing and Saving Estimates • Installation and Grounding • Validation – Site Acceptance Testing • Areas for additional Patent Protection

  24. Verification of the EBU • The manufacture invested in Wilkes University and Lehigh University to provide independent and qualified 3rd party verification. • We know the technology works. • The investment was made to differentiate the EPIC from other vendors claims on their technology. • Many competitors do not have patents or hold patents and the sizing of the systems and not in the technology itself. • Much of the competition have a capacitor in a box design to correct only power factor. • Vendors have unqualified “client testimonials” on their websites. • The manufacture holds many patents on the EPIC and independent testing from Wilkes University and Lehigh University along with backing from Ben Franklin Technology Partners of PA.

  25. END USER BENEFITS • Reduce Electric Utility Consumption • Reduce Electrical Utility Billing • Reduce Demand Charge • Reduce Repairs & Maintenance • Gain lightning/surge protection • Protect in building equipment • Improve Business Continuity • Extend Equipment Life & ROI • Reduce Utility Power Factor Surcharge • Mitigate Utility Service Upgrade • Qualify for Future State Grants, • Smart Start Rebates & Carbon Credits

  26. UTILITY COMPANY BENEFITS • Increase Fossil Fuel efficiency – greater ROI for utility company on their primary commodity • Reduce Fossil Fuel consumption & Carbon Footprint • Ability to serve more buildings with fewer transformers • Ability to re-sell spare capacity built & budgeted for commercial demand spikes • Increase earnings on profit dollars by utilizing spare capacity and delaying new Fossil Fuel & Nuclear plant build outs

  27. Never waste energy

  28. Competitive Positioning/Advantage • Competitive Analysis reveals that surge suppression and harmonics reduction markets are dominated by 4 large OEMs( Eaton, GE, ABB, Siemens). • All companies in this larger space are focused on advanced power management and protection in mission critical applications such as large data centers • These companies have no products which claim to reduce kWh • There do exist small companies that claim an open ended & unverified energy efficiency of 3% to 35% • No proof or documentation is offered to substantiate these claims • Crude testimonials are offered on websites • Inspection of these solutions show off the shelf capacitors in a box design • Capacitors do not reduce kWh usage • Capacitors offer a mild Power Factor upgrade

  29. EPIC Models - New • Model R50 • Monthly Electric kWh Usage: 200 – 800 • Voltage: 120/240 V • Current: 200 A • Frequency: 50/60 Hz • Breaker: 2 pole 15 A • Connection: Hard wired • THHN Single Cond: #10 • Dimensions: 6” X 6” X 4” • Weight: 8 lbs • Power dissipation per 8X20 µsec: > 47,808 Joules • Peak pulse current: > 40,000 A • Max surge current per 8X20 µsec: 30,000 A • Effective range: 5 – 50 A • Max Voltage 360 Volts ac 50/60 Hz • Must Have 8Ft Ground Rod

  30. EPIC Models • Model R100 • Monthly Electric kWh Usage: 700 – 2,000 • Voltage: 120/240 V • Current: 200 A • Frequency: 50/60 Hz • Breaker: 2 pole 20 A • Connection: Hard Wired • THHN Single Cond: #10 • Dimensions: 10” X 10” X 6” • Weight: 42 lbs • Power dissipation per 8X20 µsec: > 47,808 Joules • Peak pulse current > 40,000 A • Max surge current per 8X20 µsec: 15,000 A • Effective range: 16 – 100 A • Max Voltage 360 Volts ac 50/60 Hz • Must have 8FT Ground Rod

  31. EPIC Models 208 Volts • Model C100-3 • Monthly Electric kWh Usage: 700 – 3800 • Voltage: 208/240 V 3 phase • Current: 50 – 400 A • Frequency: 50/60 Hz • Breaker: 3 pole 60 A • Connection: hardwired • THHN Single Cond: #8 • Dimensions: 36” X 30” X 10” • Weight: 180 lbs • Power dissipation per 8X20 µsec: > 2,800 Joules • Peak pulse current: > 80,000 A • Max surge current per 8X20 µsec: 60,000 A • Effective range: > 30 – 200 A • Max Voltage 360 Volts ac 50/60 Hz • Must Have 8Ft Ground Wire

  32. EPIC Models 208 Volts • Model C300 • Monthly Electric kWh Usage:1,600 – 7,800 • Voltage: 208/240 V 3 phase • Current: 25 – 200 A • Frequency: 50/60 Hz • Breaker: 3 pole 30 A • Connection: hardwired • THHN Single Cond: #10 • Dimensions: 24” X 24” X 10” • Weight: 52 lbs • Power dissipation per 8X20 µsec: > 140,000 Joules • Peak pulse current: > 80,000 A • Max surge current per 8X20 µsec: 15,000 A • Effective range: 25 – 200 A • Max Voltage 360 Volts ac 50/60 Hz

  33. EPIC Models 208 Volts • Model C300-3 • Monthly Electric kWh Usage: 7,800 – 53,000 • Voltage: 208/240 V 3 phase • Current: 50 – 400 A • Frequency: 50/60 Hz • Breaker: 3 pole 60 A • Connection: hardwired • THHN Single Cond: #8 • Dimensions: 36” X 30” X 10” • Weight: 180 lbs • Power dissipation per 8X20 µsec: > 2,800 Joules • Peak pulse current: > 80,000 A • Max surge current per 8X20 µsec: 60,000 A • Effective range: > 30 – 200 A • Max Voltage 360 Volts ac 50/60 Hz

  34. EPIC Models 208 Volts • Model C450 • Monthly Electric kWh Usage: 7,800 – 53,000 • Voltage: 208/240 V 3 phase • Current: 50 – 400 A • Frequency: 50/60 Hz • Breaker: 3 pole 60 A • Connection: hardwired • THHN Single Cond: #8 • Dimensions: 36” X 30” X 10” • Weight: 180 lbs • Power dissipation per 8X20 µsec: > 2,800 Joules • Peak pulse current: > 80,000 A • Max surge current per 8X20 µsec: 60,000 A • Effective range: > 30 – 200 A • Max Voltage 360 Volts ac 50/60 Hz

  35. EPIC Models 480 Volts • Model C480 • Monthly Electric kWh Usage: 1,6000 – 27,000 • Voltage: 480/277 V 3 phase • Current: 25 – 200 A • Frequency: 50/60 Hz • Breaker: 3 pole 30 A • Connection: hardwired • THHN Single Cond: #10 • Dimensions: 24” X 24” X 10” • Weight: 95 lbs • Power dissipation per 8X20 µsec: > Joules 140,238 • Peak pulse current: > 80,000 A • Max surge current per 8X20 µsec: 60,000 A • Effective range: 25 – 200 A • Max Voltage 660 Volts ac 50/60 Hz

  36. EPIC Models 480 Volts • Model C480-3 • Monthly Electric kWh Usage: 1,6000 – 27,000 • Voltage: 480/277 V 3 phase • Current: 25 – 200 A • Frequency: 50/60 Hz • Breaker: 3 pole 30 A • Connection: hardwired • THHN Single Cond: #10 • Dimensions: 24” X 24” X 10” • Weight: 95 lbs • Power dissipation per 8X20 µsec: > Joules 140,238 • Peak pulse current: > 80,000 A • Max surge current per 8X20 µsec: 60,000 A • Effective range: 25 – 200 A • Max Voltage 660 Volts ac 50/60 Hz

  37. EPIC Models 480 Volt • Model C500 • Monthly Electric kWh Usage: 27,000 – 163,000 • Voltage: 480/277 V 3 phase • Current: 1,000 A • Frequency: 50/60 Hz • Breaker: 3 pole 60 A • Connection: hardwired • THHN Single Cond: #4 • Dimensions: 36” X 30” X 10” • Weight: 255 lbs • Power dissipation per 8X20 µsec: > Joules 757,404 • Peak pulse current: > 80,000 A • Max surge current per 8X20 µsec: 120,000 A • Effective range: 45 - 1,000 A • Max Voltage 660 Volts ac 50/60 Hz

  38. EPIC Models 480 Volt • Model C600 • Monthly Electric kWh Usage: 164,000 – 350,000 • Voltage: 480/277 V 3 phase • Current: 2,000 A • Frequency: 50/60 Hz • Breaker: 3 pole 100 A • Connection: hardwired • THHN Single Cond: #4 • Dimensions: 36” X 36” X 10” • Weight: 350 lbs • Power dissipation per 8X20 µsec > Joules 1,514,556 • Peak pulse current: >160,000 A • Max surge current per 8X20 µsec: 120,000 A • Effective range: 52 - 2,000 A • Max Voltage 660 Volts ac 50/60 Hz

  39. EPIC Models 480 Volt • Model C650 (Under development) • Monthly Electric Usage: N/A • Voltage: 480/277 V 3 phase • Current: 2,000 A • Frequency: 50/60 Hz • Breaker: 3 pole 200 A • Connection: hardwired • THHN Single Cond: #2 • Dimensions: 24” X 24” X 8’ • Weight: 550 lbs • Power dissipation per 8X20 µsec: > 56,520 Joules • Peak pulse current: > 46,000 A • Max surge current per 8X20 µsec: 120,000 A • Effective range: 100 - 2,000 A • Max Voltage 660 Volts ac 50/60 Hz

  40. Summary • No product or technology exists in the marketplace like the EPIC. • No competing product exists with the capabilities, validations (both customer and theoretical), or actual data. • EE Green provides a 5 yr warranty on its products and guarantees the savings or we will prorate your investment down to the actual demand reduction! • Typical ROIs are 2 yrs! Thank You!!!

More Related