1 / 12

ANSI/ANS-3.11 Determining Meteorological Information at Nuclear Facilities

ANSI/ANS-3.11 Determining Meteorological Information at Nuclear Facilities. Stanley L. Marsh, CCM, Southern California Edison 8th NUMUG Meeting St. Charles, IL May 9, 2002. ANSI/ANS-3.11. Purpose

hall-lee
Download Presentation

ANSI/ANS-3.11 Determining Meteorological Information at Nuclear Facilities

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ANSI/ANS-3.11 Determining Meteorological Information at Nuclear Facilities Stanley L. Marsh, CCM, Southern California Edison 8th NUMUG Meeting St. Charles, IL May 9, 2002

  2. ANSI/ANS-3.11 • Purpose • Report on ANSI/ANS-3.11, a new Standard for Determining Meteorological Information at Nuclear Facilities. • Explore nuclear industry position on approaching NRC for their endorsement of ANSI/ANS-3.11. • Initiate steps to reaffirm, revise, or modify ANSI/ANS-3.11.

  3. ANSI/ANS-3.11Attributes • Reflects the current operational and regulatory climate by incorporating state-of-the-art data acquisition, processing, and recording technology. • Applicable to all nuclear facilities nationwide, civilian nuclear power industry and Federal government. • Replaces ANSI/ANS-2.5; clarifies existing issues and provides additional guidance without imposing new requirements. • Represents a technically sound, state-of-the-art standard without consideration of regulatory forcing functions.

  4. Why Was ANSI/ANS-2.5 Replaced? • No longer active per ANS Standards rules • Technically outdated • Emphasizes siting, not operation of nuclear facilities • Does not reflect current in situ meteorological instrumentation standards • Does not consider remote sensing technology • Does not reflect state-of-the-art data acquisition, processing, and archiving technology • Inconsistent with USEPA and ASTM guidance • Addresses only civilian nuclear power plants and not all non-reactor nuclear facilities • Does not address meteorological program life cycle considerations • Does not fully address complex terrain siting and operational issues • Inconsistent with NEXRAD, ASOS, EPA, and ASTM guidance

  5. ANSI/ANS-3.11Design Criteria • Replace ANSI/ANS-2.5, not just revise it. • Applicable to both civilian nuclear power industry and Federal Gov’t nuclear facilities. • Applicable to meteorological monitoring supporting siting, licensing, operation, emergency response, decontamination, and decommissioning of nuclear facilities. • Reside in ANS-3.0, Operations. • Rely on existing, technically sound, meteorological guidance. • Develop new guidance only where necessary. • Stand alone, technically sound document.

  6. ANSI/ANS-3.11 WG PARTICIPANTS AND STRUCTURE WG ELEMENT I: CHAIRMEN OVERSIGHT AND FACILITATION NUMUG Rep: Stan Marsh (SCE)DMCC Rep: Carl Mazzola (SW) WG ELEMENT II: TECHNICAL RESEARCHERS AND WRITERS DEVELOPMENT OF TECHNICAL MATERIALS Mark Abrams Vendor PLGBob Banta Fed Research ERL/ETLTom Bellinger Fed Pgm IDNSPaul Fransioli Consultant SAICBrad Harvey Util Pgm Mgr DESIStan Marsh Util Pgm Mgr SCE Carl Mazzola Consultant SW Matt Parker Fed Pgm WSRCKen Wastrack Util/Fed Pgm TVA

  7. WG ELEMENT III: PEER REVIEWERS Rob Addis Fed Pgm Mgr WSRCRon Baskett Fed Pgm Mgr LLNLLeta Brown Regulator NRCBruce Carson Util Pgm PP&LTom Coulter Regulator EPAJerry Crescenti Fed Pgm Mgr INEELJim Fairobent Fed Pgm DOE/SOJim Holian Consultant SAICJohn Irwin Regulator EPABob Kornasiewicz Regulator NRCStanley Krivo Regulator EPA IVTom Lockhart Consultant MSIDoyle Pittman Util Fed Pgm TVADarryl Randerson Fed Pgm Mgr NTSGene Shelar Util Pgm PG&EIrv Spickler Fed Pgm DOE/EMBob Swanson Consultant CCCPing Wan Consultant BechtelMarvin Wesely Fed Pgm ANLBob Yewdall Util Pgm Mgr PSE&G ANSI/ANS-3.11 WG PARTICIPANTS

  8. NRC RESPONSE (7/94) “…we are not aware of any safety issues which would suggest that a revision of this Regulatory Guide (1.23) is in order.” “…NRC approval is not needed for ANS to revise the subject standard.” “We cannot make a commitment at this time to endorse the revised ANSI/ANS-2.5 (ANSI/ANS-3.11) without a compelling safety argument.” “…the NRC will determine how to support your activity.” ANSI/ANS-3.11REGULATORY IMPLICATIONS

  9. NRC’S CURRENT POSITION ON METEOROLOGY (05/02) SAFETY GUIDE 23 (AKA, R.G. 1.23) IS STILL IN EFFECT. PROPOSED REV. 1, AND 2nd PROPOSED REV. 1 TO R.G. 1.23 WERE NEVER ADOPTED. AT PRESENT, THERE IS NO EFFORT, ONGOING OR PLANNED WITHIN NRC, FOR AN UPDATE OR REVISION. NRC IS WAITING FOR AN INDUSTRY TRADE GROUP (e.g. NUMUG) TO TAKE THE INITIATIVE TO GET ANSI/ANS-3.11 RECOGNIZED. ANSI/ANS-3.11REGULATORY IMPLICATIONS

  10. UPDATES/REVISIONS TO ANSI/ANS-3.11 THROUGH REAFFIRMATION PROCESS REAFFIRM “AS IS” BY 2/16/05 REVISE (MINOR EDITORIAL REVISIONS) MODIFY (MAJOR REVISIONS) REACTIVATE THE ANSI/ANS-3.11 WG VOLUNTEERS FOR WG MEMBERS? VOLUNTEERS FOR WG CHAIR? WG KICKOFF MEETING PLANNED AT AMERICAN METEOROLOGICAL SOCIETY (AMS) ANNUAL MEETING IN LONG BEACH, CA, FEBRUARY 2003 DEVELOPMENT OF OTHER METEOROLOGICAL STANDARDS ANSI/ANS-3.11 WORKING GROUP (WG) FUTURE

  11. Should NUMUG initiate discussions with NRC to gain endorsement of ANSI/ANS-3.11? Yes No Should NUMUG support WG to seek re-affirmation of ANSI/ANS-3.11? Yes No Would you serve as a member on the ANSI/ANS-3.11 WG? Yes No Would you Chair the ANSI/ANS-3.11 WG? Yes No Comments/Ideas _________________________________________________ _________________________________________________ Name ________________________ Affiliation _______________________ Please tear out this page and leave with NUMUG Steering Committee member at the end of day. ANSI/ANS-3.11 NUMUG SURVEY

  12. ANSI/ANS-3.11 • HOW DO I PURCHASE A COPY? • WRITE OR CALL, AMERICAN NUCLEAR SOCIETY 555 NORTH KENSINGTON AVENUE LA GRANGE PARK, ILLINOIS 60526 Attn.: ANS STANDARDS MANAGER (708) 352-6611 (708) 352-0499 (FAX) E-mail at NUCLEUS@ans.org http://www.ans.org

More Related