1 / 63

Chapter 13

Chapter 13. Concrete Form Design. Frame Construction. Framing member in usually of 2 in (5cm) nominal thickness Then this frame are covering with siding and roof sheathing of plywood or lumber. The two principals forms of frames are:

gerhardt
Download Presentation

Chapter 13

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Chapter 13 Concrete Form Design

  2. Frame Construction • Framing member in usually of 2 in (5cm) nominal thickness • Then this frame are covering with siding and roof sheathing of plywood or lumber. • The two principals forms of frames are: • Platform frame construction(in this type of platform the subfloors extends to the outside of the building walls) as shown in figure (11-3) • Balloon frame Construction(in this type of platform the exterior wall studs extends all the way from the sill to the top of the second floor wall) as shown in figure (11-4)

  3. Foundation and Roof Construction • Platform frame Construction supported by foundation walls as illustrated in figure (11-5) • In this illustration the floor joints are lapped and rest on top of the girder rather than on the ledger as in figure (11-3). • And as in figures(11-7) for slab in grade and figure (11-8) as combined slab foundation

  4. Roof Construction • One method of roof Construction called Joist and Rafter Framingas illustrated in Figure (11-11). • The Rafters are notched where are placed on the wall plates and are held in place by nailing them to the wall plates. • The Collar Beam shown is used to assist in resisting wind loads on the roof. • In figure (11-9) all the anchors and joist hangers that are using in Frame Construction

  5. Concrete Form Design • SLAB FORM DESIGN Method • https://www.youtube.com/watch?v=jggeUUbPHZs • https://www.youtube.com/watch?v=uGU8xgJykO0

  6. Concrete Form Design • Formwork materials can be classified as: • Lumber and Timber (Wood) • Metals • Plastic

  7. 1. Timber Formwork

  8. 1. Timber Formwork • Lumber: Lumber is commonly available material and has excellent strength, weight and cost factor • Lumber is classified as: • Boards: 1 to 1.5 inches thick, 2 or more inches width • Dimensions: 2 to 4 inch thick, any width. • Timbers: 5 or more inches thickness, 5 or more inches width

  9. 1. Timber Formwork b. Plywood: • The use of plywood in concrete forming for form facing has improved the quality of finished concrete. • The relatively large sheets of plywood have reduced the cost of building and at the same time have provided smooth surfaces that reduces cost of finishing of concrete surfaces

  10. 2. Metal Formwork

  11. 2. Metal Formwork • The initial cost of metal formwork is more than timber formwork but the lumber of reuses of metal formwork is higher than that of timber. • In long run metal formwork can be economical. • In heavy construction works metal formwork may require a lifting mechanism to handle the formwork panels or props.

  12. 2. Metal Formwork • Steel sheet formwork has the problem of rusting also. To avoid rusting, in every use the surfaces should be oiled with an appropriate releasing agent. • in metal formwork usage, the metal sheets are prepared as panels of standard sizes. This brings the difficulties of erecting irregular dimensions of formwork. • Steel or aluminum or magnesium is the most widely used metals.

  13. 3. Plastic Formwork

  14. 3. Plastic Formwork • They have impervious surfaces that usually create a smooth fınish to the concrete. • Plastic formwork could be reinforced or un-reinforced. • Plastic is reinforced by glass fibers. • Reinforced plastics are specially produced for a specific formwork type. • Un-reinforced plastics are produced in sheet form with smooth or textured surfaces. • Plastic formwork is lighter but less durable than metal formwork.

  15. Formwork Design • Floor and Roof formwork Design: The design load that acts on the slab form consist of : • self-weight of the reinforced slab plus • the live load and, • the weight of the formwork themselves.

  16. The American concrete institute (ACI) recommended a minimum live load of: • 2.4kpa In case of motorized concrete buggies are used • 3.6kpa • ACI recommended a minimum design load (dead plus live) : • 4.8kpa In case of motorized concrete buggies are used : • 6.0 kpa

  17. Design steps: • Selecting the design load. • Analyzing the sheeting, joist and stringers as beam under uniformly distributed load supported over one of the three conditions (single span - two spans – three spans or larger). • Determining the allowable span for slab from table (13-5& 13-5A) by considering the smallest span based on the value of bending, shear and deflection.

  18. Design the sheathing(decking). • Design the joist. • Design the stringers. • Check the stringer spans and shore capacity. • Check the crushing between joist and stringer.

  19. Maximum bending moment, shear force and deflection developed by uniformly distributed load can be obtained from table below:

  20. The maximum fiber stress developed in bending, shear and compression resulting from a specified load can be determined from the upper equations.

  21. Example (13-1) Determine joist spacing, stringer spacing, and shore spacingof the following Data: • Design the formwork (Figure 13-2) for an elevated concrete floor slab 6 in. (152 mm) thick. • Assume that all members are continuous over three or more spans. • Commercial 4000-lb (17.8-kN) shores will be used. • It is estimated that the weight of the formwork will be 5 lb/sqft (0.24 kPa).

  22. Example (13-1) The adjusted allowable stresses for the lumber being used are as follows: • Maximum deflection of form members will be limited to l/360. • Use the minimum value of live load permitted by ACI.

  23. Figure (13-2) Slab

  24. Figure (13-2) Slab

  25. Solution

  26. 1. Deck Design (Joist Spacing) • Consider a uniformly loaded strip of decking (sheathing) 12 in. (or 1 m) wide placed perpendicular to the joists (Figure 13-1a) and analyze it as a beam. • Assume that the strip is continuous over three or more spans and use the appropriate equations of Table (13-5) and (13-5A) in the following Page. • w =(1 sq. ft/in ft) x (130 lb/sq ft) = 130 lb/ft • [w =(1 m2/in m) x (6.21 kN/m2) =6.21 kN/m]

  27. Figure 13-1 Design Analysis for form member

  28. 1. Deck Design (Joist Spacing)

  29. 1. Deck Design (Joist Spacing)

  30. 1. Deck Design (Joist Spacing)

  31. 1. Deck Design (Joist Spacing) • Deflection governs in this case and the maximum allowable span is 27.7 in. (703 mm). • We will select a 24-in (610-mm) joist spacing as a modular value for the design.

  32. 2. Joist design • Consider the joist as a uniformly loaded beam supporting a strip of design load 24 in. (610 mm) wide (same as joist spacing; see Figure 13-1b): • Joists are 2 x 8 in. (50 x 200 mm) lumber. • Assume that the joists are continuous over three spans. • wdesignload= (wconcrete+wformwork+wLiveload)x Area x Depth from sheathing (the least) • w =(2 ft) x (1) x (130 lb/sq ft) =260 lb/ft • [ w =(0.610 m) x (1) x (6.22 kPa) = 3.79 kN/m]

  33. Figure 13-1 Design Analysis for form member

  34. 2. Joist design

  35. 2. Joist design

  36. 2. Joist design

  37. 2. Joist design • Thus bending governs and the maximum joist span is 87 in. (2213 mm). • We will select a stringer spacing (joist span) of 84 in (7 ft). (2134 mm).

  38. 3. Stringer Design (shore spacing) • To analyze stringer design, consider a strip of design load 7 ft (2.13 m) wide (equal to stringer spacing) as resting directly on the stringer (Figure 13-1c). • Assume the stringer to be continuous over three spans. • Stringers are 4 x 8 (100 x 200 mm) lumber (given) • Now analyze the stringer as a beam and determine the maximum allowable span. • w =(7) (130) =910 lb/ft • [w =(2.13) (1) (6.22) = 13.25 kN/m]

More Related