1 / 10

Material Measurement of TT2-111R

Material Measurement of TT2-111R. Measurements provided by TT. Material Measurement of TT2-111R. This ferrite is readily available in tiles of 6 cm x 6 cm and 5 mm thickness; Material samples are “wrapped” around an inner conductor; this allows a non-destructive measurement,

gamba
Download Presentation

Material Measurement of TT2-111R

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Material Measurement of TT2-111R Measurements provided by TT Christine Vollinger & Fritz Caspers

  2. Material Measurement ofTT2-111R • This ferrite is readily available in tiles of 6 cm x 6 cm and 5 mm thickness; • Material samples are “wrapped” around an inner conductor; • this allows a non-destructive measurement, • without any machining of the ferrite. Christine Vollinger & Fritz Caspers

  3. Material Measurement of TT2-111R Side walls made of Plexiglas to allow “wave leakage”(no unwanted HO modes). SH-sample holder It is much simpler to machine metal than ceramics with adequate accuracy… Embedded conductor (brass) Christine Vollinger & Fritz Caspers

  4. TT2-111R, Reverse Calculation of S21 TT2-111R, Measurement of S21 Christine Vollinger & Fritz Caspers

  5. Material Measurement of TT2-111R /S-Params Red= Measurement in SH-sample holder Blue= Reverse Calculation from TT-data; We can’t really say which numbers are “more correct”… Christine Vollinger & Fritz Caspers

  6. Material Measurement of TT2-111R /Permeability Red= Measurement in SH-sample holder; Blue= Measurement provided by TT. Christine Vollinger & Fritz Caspers

  7. Material Measurement of TT2-111R /Permeability TT Data Meas. w.short TT Data Meas. w. short • Additional measurement with SH-sample holder terminated with SHORT • Permeability calculated from input impedance: z1=jZL tan(βl) -> valid for low frequencies, only (up to about λ/4) ! • Method with SHORT termination is also limited for absorbing materials due to the material damping. Christine Vollinger & Fritz Caspers

  8. Material Measurement of TT2-111R Conclusion • A transmission measurement is used for the measurement of material parameters of ferrite samples; • Material samples are “wrapped” around an inner conductor; • this allows a non-destructive measurement, • without any machining of the ferrite. • Measurement for frequencies < 1 GHz show a limited sensitivity to air gaps in the samples, this is advantageous; • For measuring above approx. 1 GHz, smaller sample lengths would be required (we already reach -80 dB at 1 GHz). • Influence of an air gap can be tested as it is possible to measure with defined air gaps. • This method is used as it is much simpler to machine metal thanceramics with adequate precision. Christine Vollinger & Fritz Caspers

  9. Material Measurement of TT2-111R /Permeability Red= Measurement in SH-sample holder; Blue= Measurement provided by TT. Christine Vollinger & Fritz Caspers

  10. Cross-check: comparison of measurement of empty SH-sample holder with calculated S-parameters Christine Vollinger & Fritz Caspers

More Related