Multipixel Geiger mode photo-sensors (MRS APD’s)

Multipixel Geiger mode photo-sensors (MRS APD’s). INR, Moscow. Yury Kudenko. ISS meeting, KEK, 25 January 2006. Near Detectors at 280m. Off-axis (~2 o ). ND280m hall.  19 m. Super-K. 37 m. Beam center. On-axis (0 o ). - ~ 10 5 WLS fiber channels - individual readout.

fisseha
Download Presentation

Multipixel Geiger mode photo-sensors (MRS APD’s)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Multipixel Geiger mode photo-sensors (MRS APD’s) INR, Moscow Yury Kudenko ISS meeting, KEK, 25 January 2006

  2. Near Detectors at 280m Off-axis (~2o) ND280m hall 19m Super-K 37m Beam center On-axis (0o) - ~ 105 WLS fiber channels - individual readout

  3. Principles of MRS APD operation CPTA, Moscow (MRS APD) MePhi/PULSAR, Moscow (SiPM) Dubna Multipixel Geiger mode APD’s invented in Russia in 1980’s Number of pixels  450 - 4000 limited Geiger mode PMT: diameter 20 mm MRS: active area 1x1mm2 diam 1 mm Depletion region  2m Drift velosity  107 cm/s Field  (2-3)x105 V/cm Qpixel = Cpixel x V = Cpixel x (Vbias - Vbreakdown) Cpixel  50fmF V  few volts  Qpixel  2x106 electrons

  4. MRS APD One pixel ~ 40 x 40 m2

  5. MRS APD - Diameter of active area 1.1 mm - Number of pixels 556 - Geometrical efficiency 70-80 % - Photon detection efficiency at th=0.5 p.e. and dark rate ~1MHz 10-15% - Bias voltage range 25-75 V - Gain 106 - 107 - Sensitivity to magnetic field( 9T) no - Cross talk 4-6% - Auto calibration and control separated p.e. peaks - Dark noise rate (th =0.5 p.e)  1 MHz • New devices • - Dark noise rate • PDE • - Dynamic range, linearity of signal • - Temperature effects • - Long time stability • Lifetime • Recovery time LED signal

  6. Dark noise rate 1pe 2pe 3pe Dark noise rate Threshold, p.e. Dark rate, MHz 0.5 1.0 1.5 ~0.1 2.5 0.01 Temperature dependence ~70 – 100 kHz/deg

  7. Photon detection efficiency (PDE) PDE=εpixel × QE × εGeiger 30-70% 60-80% 50-80% PDE=12% 1 MHz Typical PDE ~12% (at 1 MHz (th=0,5 p.e.) New CPTA devices PDE ~15%

  8. Linearity and cross talk MRS APD, 556 pixels The same LED signal to MRS APD and PMT through Y11 fiber Crosstalk Bias voltage = 40.0 V Dark rate (0.5p.e) ~ 1MHz Crosstalk = 5-6%

  9. Temperature effects PDE gradient ~ -1.8%/deg Dark noise rate gradient ~70-90 kHz/deg

  10. Stability and lifetime study High temperature test l.y. measurement After temp correction For 2 years ~150 CPTA devices are studied 3 dead On-going test: 10 devices are at 80 deg and HV for 15 days All OK

  11. Recovery time Dec’05 MRS #1710-002 t First pulse: Black – 50 p.e Red - 100 p.e. Green - 300 p.e. Second: - 100 p.e. Large pulse >600 p.e. Second pulse ~100 p.e.

  12. Beam test of SMRD detector SMRD: about 5000 extruded scintillator slabs ~ 90 cm x 20 cm x 1.0 cm Beam test at KEK, Nov 2005. Sci/WLS/(both end MRS readout) detector 1.4 GeV/c pions and protons Extruded scintillator (Vladimir, Russia) Chemical reflector Fiber KURARAY Y11, double clad, 1 mm 8p.e. l.y. from one end of slab Ped

  13. Beam test results Beam scan along the slab Time resolution S-type SMRD detector: l.y. (sum of 2 ends) 152 p.e. MIP efficiency >99% Timing at 15 p.e. ~ 1.7 ns () Space resolution ~12 cm ()

  14. Summary and outlook Status Perspectives Diameter 1.1mm1.1, 1.2-1.5 mm PDE 12-15%OK,R&D  20% Dark noise rate ~1 MHz (0.5 p.e.) manufacturers aim to decrease 100 kHz (1.5 p.e)OK Time resolution 1- 3 ns () with Y11 OK, both end readout to suppress noise Cross talk  4-6%OK Gain 106 – 107 OK Linearity range 200 p.e. 600 pixelsOK, 1000-2000 pixels 20-30 p.e. 100 pixelsOK for SMRD, on-axis Long term stability ~1000 hrs, 1-2%OK,more tests Lifetime 3 of450 are deadlooks not bad,study is ongoing Temperature Dark noise rate +(70-90) kHz/deg PDE -1.8%/deg22-25 deg OK,low temp is better Recovery time  1-5 sOK - Great progress in development of Multi-pixel Silicon devices for last 2-3 years - Such devices are now considered as base-line photo-sensors for the T2K near detector at 280 m