1 / 17

HAMC = H all A M onte C arlo

HAMC = H all A M onte C arlo. C. Contributors: Dustin McNulty, Diancheng Wang. ROOT / C++ Design Somewhat like “SAMC” & “genercone” For HRS only. Uses LeRose transfer functions. Abstract classes: Experiment, Physics, Target

elaine
Download Presentation

HAMC = H all A M onte C arlo

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. HAMC = Hall AMonte Carlo C Contributors: Dustin McNulty, Diancheng Wang • ROOT / C++ Design • Somewhat like “SAMC” & “genercone” • For HRS only. Uses LeRose transfer functions. • Abstract classes: Experiment, Physics, Target • Used by HAPPEX-3, PVDIS, and PREX. A. Deur, V. Sulkosy D. Lhuillier, K. Paschke, B. Moffit or matrices, or “Guido” fcn.

  2. Applications of HAMC C • Estimate Rates, Asymmetry, Sensitivity to Physics • Design Collimator, Sieve, “A_T” detector. • Design integrating detector & focus at detector • Estimate sensitivities to beam parameters. • Effects of radiative corrections, acceptance.

  3. HAMC Events Objects • Generate beam • Target position uniformly sampled (raster option) • Fill solid angle uniformly • Cross-section computed for rates and weighting • Asymmetry computed (for Parity Expts) • Energy losses (Brehms and dE/dX) with MC methods • Multiple Scattering • Transport to various points in HRS and Septum • Acceptance cuts applied at apertures • Event Analysis on accepted events.

  4. Transport PolynomialsfromJohn LeRose (same)

  5. Transport Polynomials (part 2) thanks, John LeRose Was used to check where electrons scrape; e.g. not in iron of dipole ?

  6. Cross Section Input Shown here for Lead

  7. Does HAMC work ? Yes, well enough for our goals. A problem:Radiative tail out to high loss is underestimated. Use “effective target” size to adjust (reduce) predicted rates.

  8. Comparing HAMC to Real Data This was done for HAPPEX-1, HAPPEX-2, and a Lead test run

  9. More Comparisons …

  10. A Lead Test run in 2005 (using old septum magnet)

  11. PREX Design : At 50the Optimal FOM is at 1.05 GeV (+/- 0.05) RN 1% @ ~1 GeV

  12. Collimator at entrance to spectrometer  Suppressing A_T systematics Paul Souder Aligned in spectrometers to define identical Left / Right scattering angles as well as good up / down symmetry A_T hole Be degrader Insertable blocker to block Be

  13. HAMC Design of Collimator All Events Collimator

  14. Events from A_T hole (Be plug) Main detector A_T detector Measures horizontal A_T systematic. (Vertical is measured from Left/Right spectrometers) Thanks: Dustin McNulty Krishna Kumar Paul Souder

  15. Sieve Slit Design Few more holes drilled to improve coverage and accuracy.

  16. Analysis for Workshops and Future Publication Acceptance Function Credit: C. J. Horowitz

  17. Conclusions re: HAMC C The GOOD • Reproduces data -- well enough. • Has aided in several estimates and design efforts. • Underestimates radiative losses -- maybe another MC better ? • Restricted to HRS and single-arm at the moment. • Might be easy to make a coincidence base class. The BAD

More Related