This document details the specifications for functional performance in high voltage systems, focusing on inrush current events. Key parameters include an isolation voltage threshold of 0.0001 A and an over-voltage shutdown threshold at 450 VDC +/- 5%, with returning values at 430 VDC +/- 5%. The under-voltage derating threshold is set at 275 VDC +/- 5%, ensuring safety against excessive input currents (1.6 kW at 87% = 6.7 A). Additional features include short circuit protection, jump start capabilities, reversing battery efficiency, and full bridge centertap topology for energy storage management.
E N D
Functional Performance Mode Input Voltage Isolation 0.0001 A
Inrush Event Parameters Inrush Current Diagram
Output Voltage Rage Line Regulation, Steady and Dynamic Steady – 5% Dynamic – 10%(5 msec max) Over-Voltage Shutdown Threshold 450VDC +/-5% Returning value 430VDC +/-5% Under-Voltage Derating Threshold 275 VDC +/- 5%. The derating should be sufficient to prevent damage to the APM from excessive input currents, (1.6 kW / (87% * 275 VDC) = 6.7A).
Short Circuit Protection Jump Start Reversing Battery
Efficiency L-Terminal
Energy Storage Full bridge Centertap topology