O2X – Dissolved Oxygen Meter

O2X – Dissolved Oxygen Meter. Applications Aeration Basins, Final Effluent, Aerobic Digesters Low Maintenance No Frequent Calibration Automatic Flushing Ease of Use Long-life O 2 or O 2 O Electrode Cartridges Quick Calibration. Duo – Your choice!.

chakra
Download Presentation

O2X – Dissolved Oxygen Meter

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. O2X – Dissolved Oxygen Meter • Applications • Aeration Basins, Final Effluent, Aerobic Digesters • Low Maintenance • No Frequent Calibration • Automatic Flushing • Ease of Use • Long-life O2or O2O Electrode Cartridges • Quick Calibration

  2. Duo – Your choice! O2O Optical Clark Cell

  3. Best of Both Designs Optical O2O • No calibration required • Most stable luminophor on the market!! • Life: Cap - 3 years & electrode - 5 to10 years • Easy to replace cap • Flushing with 45-60 psig • Better for high DO & high Temp levels, cell life • Responds quicker to DO changes Clark Cell • Proven Technology • Long Cell life due to bubble cavern, 18-24 months • Excellent for low DO levels • More accurate than Optical • Flushing with 45-60 psig

  4. O2O Cerlic • Blue light excites luminescent material • Red LED provides reference signal • The time for red light to be emitted off of luminophor is measured • Phase of both signals are compared • The measurement correlates to O2 concentration, increased amounts of O2 in the liquid decreases the time it takes for the red light to be emitted.

  5. O2O Cerlic • Newest & Improved Design • New Phase Shift Technology • New focusing lens to amplify Luminophore reflection - improves accuracy • Luminophore coating is more stable - not damaged by UV • O2X will accept O2O or Clark Cell electrodes • Life: Cap - 3 years & electrode - 5 to10 years • O2X built-in flushing is standard, 45-60 psig! LDO Hach • New Model 2 that obsoletes current design? Mad - Customers & killed SC100 • Damaged by extended exposure to light • Life – 12 months on cap • Flushing – Claims no cleaning req’d. Low pressure only due to luminescent coating • Clamp on Cleaning, 3-5 psig • Prefer float ball • Will not repair sensors