1 / 35

LH2 Absorber Program and Plans

LH2 Absorber Program and Plans. Mary Anne Cummings MUTAC Review FNAL Jan 14, 2003. Mucool LH2 Absorber Collaboration. E. Almasri, E.Black, K. Cassel D. M. Kaplan, A. Obabko, N. Solomey Illinois Institute of Technology S. Ishimoto, K. Yoshimura KEK

blake-chang
Download Presentation

LH2 Absorber Program and Plans

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. LH2 Absorber Program and Plans Mary Anne Cummings MUTAC Review FNAL Jan 14, 2003

  2. Mucool LH2 Absorber Collaboration E. Almasri, E.Black, K. Cassel D. M. Kaplan, A. Obabko, N. Solomey Illinois Institute of Technology S. Ishimoto, K. Yoshimura KEK L. Bandura, M. A. Cummings, A. Dyshkant, D. Hedin, D. Kubik Northern Illinois University Z. Conway, D. Errede, M. Haney University of Illinois, Urbana-Champaign M. Reep, D. Summers University of Mississippi Y. Kuno Osaka University G. Barr, W. Lau, S. Wang Oxford University C. Darve, C. Johnstone*, A. Martinez, B. Norris, L. Pei, M. Popovic, S. Geer FNAL * also research faculty at IIT

  3. Topics R&D Motivation Windows (absorber and vacuum) Absorber manifold designs and flow tests System integration Near term plans Summary

  4. Thin Windows Design Tapered thickness near window edges can further reduce the minimum window thickness near beam: Progression of window profiles: Absorber (1) and Vacuum (2 & 3)

  5. Window manufacture (U of Miss) Flange/window unit machined from aluminum piece (torispherical 30 cm diam) Backplane for window pressure tests Backplane with connections, and with window attached

  6. Measuring the “thinnest” thickness • Two different radii of curvature • Possibly not concentric Modified torispherical design If not at the center, where?

  7. Windows tests } • Procedure (for manufacture quality control and safety performance) Three innovations: • Precision measurement of window: photogrammetric volume measurements • FEA predictions: inelastic deformation, 3 – dim included in calcs. • Performance measurement: photogrammetric space point measurement Non-standard thin window design: No closed form expression for maximum stress vs. volume pressure FEA (finite element analysis): geometry stress material strain volume pressure displacement • Progress towards meeting FNAL Safety Guidelines • Absorber and vacuum window guidelines understood • Absorber window test completed • FEA/data agreement established

  8. Photogrammetry • Contact vs. non-contact measurements (projected light dots) • “Several” vs. ~ thousand point measurements (using parallax) • Serial vs. parallel measurements (processor inside camera) • Larger vs. smaller equipment • Better fit to spherical cap. • Photogrammetry is the choice for shape and pressure measurements

  9. Photogrammetric measurements Strain gages ~ 20 “points” CMM ~ 30 “points” Photogrammetry ~1000 points

  10. Window shape measurement D. Kubik, J. Greenwood Convex Concave CMM data points Whisker = z(measured)-z(design)* *Given the design radius of curvature of the concave and convex surfaces, z(design) was calculated for the (x,y) position of each target

  11. R r d convex concave convex concave Photogrammetry resolution (shape) Alignment of sides Small triangle fit D’ Use spherical fit of small triangles D = 331.0mm +- ( 5.5mm) + (- ~10mm)

  12. Overpressure Window Test • Safety review requires overpressure and destructive tests of thin windows. • Tests to confirm Finite Element Analysis predictions for window performance.

  13. 130 m window Rupture tests “340” m window Burst at ~ 120 psi 1. 3. Leaking appeared at 31 psi ..outright rupture at 44 psi! Burst at ~ 152 psi 2. 4. Burst at ~ 120 psi “350” m window Cryo test

  14. Window # Test temp. FEA results Test results Minimum window thickness (mm) Rupture pressure (psi) Window thickness from CMM (mm) Measured rupture pressure (psi) 1 293K 0.13 48 0.114 42 2 293K 0.33 117 0.33 119 3 293K 0.345 123 0.345 120 4 80K 0.33 156 0.33* 152 • Performance measurement (photogrammetry) 1. Room temp test: pressurize to burst ~ 4 X MAWP (25 psi) 2. Cryo test: a) pressure to below elastic limit to confirm consistency with FEA results b) pressure to burst (cryo temp – LN2) ~ 5 X MAWP fromASME: UG 101 II.C.3.b.(i) Absorber window test results Discrepancies between photogrammetry and FEA predictions are < 5%

  15. FNAL Requirements: • Burst test 5 vacuum windows at room temp. to demonstrate a burst pressure of at least 75 psid for all samples. (pressure exerted on interior side of vacuum volume). • Non-destructive tests at room temperature: • External pressure to 25 psid to demonstrate no failures: no creeping, yielding, elastic collapse/buckling or rupture • Other absorber vacuum jacket testing to ensure its integrity Vacuum Windows Vacuum “bellows” window (34 cm diam): No buckling at 1st yield (34 psi) Internal pressure: burst at 83 psi

  16. LH2 Window R & D Immediate future: Manufacture and test of 21 cm “bellows” absorber window Manufacture and test of 34 cm vacuum window – internal and external pressurization *new test* New aluminum alloy (stronger) Optimize seals to manifold Stability test in the Lab G magnet **

  17. Convection absorber design Internal heat exchange: Convection is driven by heater and particle beam.Heat exchange via helium tubes near absorber wall. Flow is intrinsically transverse. Output from 2-dim Computational Fluid Dynamics (CFD) calcs. (K. Cassel, IIT). Lines indicate greatest flow near beam center. KEK prototype, S. Ishimoto

  18. Force-flow Absorber External heat exchange: Mucool ~ 100 - 300W (E. Black, IIT) Large and variable beam width => large scale turbulence Establish transverse turbulent flow with nozzles Mucool design: E158 design:

  19. LH2 Manifold R & D The driving physics issue in Mucool LH2 R & D is now fluid flow and heat removal Two separate absorber designs Flow simulations Flow tests Instrumentation

  20. LH2 flow issues… Our Challenge: Large heat deposition and beam path is through entire volume absorber! 1. Liquid must move everywhere 2. Need gauge of temperature and density uniformity Questions: What computations are helpful? Are realistic flow simulations realizable? What tests will be useful, and how quantitative can they be? What level of instrumentation will convince us of sufficient temperature uniformity?

  21. 3 dimensional FE simulations are possible but CPU intensive (W. Lau, S. Wang) Force flow simulations 3-dim and 2-dim flow simulations are consistent – use 2 dim for design and iteration. Preliminary results indicate that “bellows” window has better flow pattern in window volume.

  22. Liquid Hydrogen Heating Coil Lau/Wang FE 3-d flow simulation of KEK LH2 absorber: Convection flow simulations 3-d grid: K. Cassel CFD:

  23. Flow Tests Schlieren testing of convection flow (water) test at ANL (more quantitative program to run in 2003) J. Norem, L. Bandura Testing 3-dimensional simulations with water flow test at NIU

  24. Infrared flow test setup E. Black

  25. MTA LH2 Experiment Lab G magnet LH2 Cryostat RF cells

  26. Mucool Test Area LH2 Setup Lab G magnet

  27. MTA Force Flow Cryo System Red - HydrogenBlue – Helium Based on E158 LH2 target system

  28. LH2 Pump assembly (B. Norris et al): Pump torque transition, Motor outer shield, Cooling system, Pumping system of the outer shield, Relief valves piping. More Cryo system pictures

  29. Mucool 2003/2004 Absorber/vacuum windows manufacture and test Fluid flow/convection simulations Instrumentation and data acq. development Flow tests: Forced Flow, Convection Safety Review MTA test design finalization MICE design Japanese absorber pre-MTA LH2 run Absorber/Solenoid Tests 2004 MTA LH2 absorber staging

  30. Summary Comments On LH2 R & D We have an established window design/manufacture/certification program, for absorber and vacuum windows, completed tests on the first window prototype, and have made many technical improvements on design. We have developed new applications for photogrammetry (NIM article(s) and master’s degree in progress!) Several projects have developed from LH2 absorber concerns, ideal for university and student participation. MICE participation has advanced the Mucool program: the two flow designs are complementary; integration problems are being solved – possible hybrid for a real cooling channel likely. The above four points means that we have survived as a program the delay of the FNAL MTF construction – but this year’s construction is critical! (KEK in “prestage” LH2 tests could help) LH2 flow and heat conduction has now become the dominant physics concern for the absorber. The two flow designs will be pursued in parallel. LH2 safety is the dominant engineering concern for the cooling cell, but there has not yet been any show-stopping problems.

More Related